Page 501

GE MEDICAL SYSTEMS PROPRIETARY TO GE
D
IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL 
Chapter 9 Renewal Parts 9-9
 
Section 9-7
Mechanical Kits
Table 9-6    Operator I/O Mechanical Parts
ItemPart NamePart NumberDescriptionQtyFRU
170
Top Console Upper Casting Assembly2331665 Assembly for Service 1 2
171
Top Console Lower Casting Assembly2331858 Assembly for Service 1 2
172
Frogleg (complete)FB200340- Same as Vivid 7 -12
173Frogleg Bumper KitFC200086goes on back/top half of Frogleg arms 
-...

Page 502

GE MEDICAL SYSTEMSPROPRIETARY TO GE
D
IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL   
9-10 Section 9-7 - Mechanical Kits
9-7-1 Bumper Kit, Frogleg
 
Figure 9-5   Bumper Kit, Frogleg, Base Seen From Above
Table 9-8    Bumper Kit, Frogleg FC200086
ITEMPART NAME
PART 
NUMBER
DESCRIPTIONQTYFRU
1BUMPER CRASH PAD - Bumper Crash Rear 1 N
2BUMPER INNER BOSS  - - 1 N
3BUMPER RIGHT FROGLEG  - - 1 N
4BUMPER LEFT FROGLEG --1N
5BUMPER INNER BOSS CRASH --2N
1
2
3
4
5 

Page 503

GE MEDICAL SYSTEMS PROPRIETARY TO GE
D
IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL 
Chapter 9 Renewal Parts 9-11
Section 9-8
Operator Control Panel Brackets
Figure 9-6   Operator Panel Brackets
Table 9-9    Operator Panel Brackets
ITEMPART NAME
PART 
NUMBER
DESCRIPTIONQTYFRU
190Storage Tray Bracket 2306018 1 2
191Upper Casting Bracket 2291449 1 2
192“U” Bracket 2330476 ‘U’ Shaped Bracket, Nut is Attached to Casting 1 2
193TV/TR Front Bracket230602112
194Bulkhead Bracket2305886Does Not...

Page 504

GE MEDICAL SYSTEMSPROPRIETARY TO GE
D
IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL   
9-12 Section 9-9 - Operator Control Panel Assembly
Section 9-9
Operator Control Panel Assembly
 
Figure 9-7   Operator Control Panel Assembly (Op I/O)
Inside 
Touch Panel 
Assembly
201
201A
202202A
203204
205
206
206A
208
209
207
210
211
212 

Page 505

GE MEDICAL SYSTEMS PROPRIETARY TO GE
D
IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL 
Chapter 9 Renewal Parts 9-13
 
Table 9-10    Operator Control Panel Assembly
ItemPart NamePart NumberDescriptionQtyFRU
201
Lower Operator Panel Assembly2188902-2R3.X.X Software and above MUST USE 2188902-12
Will cross to 2188902-12 when stock is depleted11
201A
Lower Operator Panel Assembly2188902-12With Standby. Backward compatible. 
R3.X.X Software and above MUST USE11
202
A/N Keyboard -...

Page 506

GE MEDICAL SYSTEMSPROPRIETARY TO GE
D
IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL   
9-14 Section 9-10 - Monitor Assembly
Section 9-10
Monitor Assembly
 
 
Figure 9-8   Monitor Assembly
Table 9-11    Monitor Assembly
ItemPart NamePart NumberDescriptionQtyFRU
301
Open Frame Monitor2283334- Same as Vivid 7 & LOGIQ 7-11
302
Monitor Cable Assembly2304171- Same as Vivid 7 & LOGIQ 7-12
303
Speaker and Mounting Bracket Kit229788222
304Monitor Tilt/Swivel/Male Post2284225Neck Assembly12...

Page 507

GE MEDICAL SYSTEMS PROPRIETARY TO GE
D
IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL 
Chapter 9 Renewal Parts 9-15
Section 9-11
Front End Processor Assembly
 
Figure 9-9   Front End Processor Assembly
Empty Card Slot
BT’01 
Card 
Rack
BT’02, 
BTCard 
Rack
401
402402A
402
411411A411B
403404
405
405A405B
406
406A
406B
407
408409
409A409C
409B
410
412 

Page 508

GE MEDICAL SYSTEMSPROPRIETARY TO GE
D
IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL   
9-16 Section 9-11 - Front End Processor Assembly
Section 9-11      Front End Processor Assembly (cont’d)
 
Table 9-12    Front End Processor Assembly
Applications SoftwareR2.X.XR3.X.X
LOGIQ 9
Model Number
ItemPart Name
Part 
Number
DescriptionQtyFRU
401
Back Plane2260219XXXXX Front End Back Plane 1 2
402
SCB12260214-2XScan Control Board
Use 2260214-3 if stock is depleted11
402A
SCB1.12260214-3
X
1XScan...

Page 509

GE MEDICAL SYSTEMS PROPRIETARY TO GE
D
IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL 
Chapter 9 Renewal Parts 9-17
1 SCB1 can be used on this model number also.
2 EBM can be used on this model replacing the BMP4 and EQ4. However EBM requires SCB1.1 at a minimum.
3 RF Amp1.2 can be used in this model number also.
4 FEPS2 and FEPS2.1 can be used on this model number. However, must also use FEP Card Rack Cover Kit 2374426.
5 FEPS2.1 can also be used on these model numbers
409A
FEPS22273641-3...

Page 510

GE MEDICAL SYSTEMSPROPRIETARY TO GE
D
IRECTION 2294854-100, REVISION 3  LOGIQ™ 9 PROPRIETARYMANUAL   
9-18 Section 9-12 - I/O Interfaces
Section 9-12
I/O Interfaces
 
 +
Figure 9-10   I/O Interfaces
Table 9-13    I/O Interfaces
ItemPart NamePart NumberDescriptionQtyFRU
451
External I/O AssemblyFB200198- Same as Vivid 7 -11
452
Internal I/O AssemblyFB200197- Same as Vivid 7 -
Obsolete - Use FC2004231N
452A
Internal I/O AssemblyFC200423- Same as Vivid 7 -
Has gain increase for improved microphone...