Page 181
GE MEDICAL SYSTEMS PROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL Chapter 5 Components and Functions (Theory) 5-51 Figure 5-37 LEDs on Modem’s Front Panel Table 5-32 LEDs on Modem LED Color Description Normally State - RedTD (Transmit Data) Flashes during use. - RedRD (Receive Data) Flashes during use. - RedCD (Carrier Detect)ON when detecting a carrier from another modem and during communication. OFF indicates no or broken connection. - Red56 (56K...
Page 182
GE MEDICAL SYSTEMSPROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL 5-52 Section 5-13 - Power Distribution Section 5-13 Power Distribution 5-13-1 Basic Overall AC Power Distribution Figure 5-38 Overall Power Distribution Select AC Voltage for Peripherals on AC Distrubution Box (PWB): 115 VAC or 230 VAC. FilterMains Power Breaker Inrush Limit 115 or 230 VAC Transformer 20 VAC 230 VAC 115 VAC Fan RegulatorFan DC Power TX Power DC Voltages to Cards Front-End...
Page 183
GE MEDICAL SYSTEMS PROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL Chapter 5 Components and Functions (Theory) 5-53 5-13-2 Overview The AC Power’s main tasks are to supply the various internal subsystems with AC power and to galvanically isolate the scanner from the on site Mains Power System. To reduce inrush current, an inrush current limiter as well as an EMI filter. Voltage to peripherals can be configured to either 115 VAC or 230 VAC. The AC Power also controls...
Page 184
GE MEDICAL SYSTEMSPROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL 5-54 Section 5-13 - Power Distribution 5-13-3AC Power PWB (cont’d) The Transformer is the galvanic barrier between the rest of the scanner and the on site AC Mains. Input voltage to the transformer can be either 230VAC or 115 VAC (two different part numbers/FRUs). The configuration of the plug on the cable to the AC Transformer is different for the two AC Voltages. From the AC Transformer, there are...
Page 185
GE MEDICAL SYSTEMS PROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL Chapter 5 Components and Functions (Theory) 5-55 5-13-4 AC Controller Differences Figure 5-41 Original AC Controller Functions
Page 186
GE MEDICAL SYSTEMSPROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL 5-56 Section 5-13 - Power Distribution Figure 5-42 AC Controller FC200403/FC200404
Page 187
GE MEDICAL SYSTEMS PROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL Chapter 5 Components and Functions (Theory) 5-57 Section 5-14 Mechanical Descriptions 5-14-1 Monitor • Tilt: 10° forwards and backwards • Swivel: 90° rotation. 5-14-2 Top Console Positioning • Vertical Access: The control panel offers 27 inches (200 mm) of vertical adjustment. • Horizontal Access: The control panel offers 45° of horizontal adjustment when the Z-arm is released.Figure 5-43 Top Console...
Page 188
GE MEDICAL SYSTEMSPROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL 5-58 Section 5-14 - Mechanical Descriptions 5-14-3 Wheels/Brakes Check that the brakes and direction locks function as described below. NOTE: The swivel lock and brake cannot be engaged (pressed down) at the same time since pressing the main brake releases the swivel lock and pressing the swivel lock releases the main brake. Therefore, if the swivel lock is engaged you need to press the main brake...
Page 189
GE MEDICAL SYSTEMS PROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL Chapter 5 Components and Functions (Theory) 5-59 Section 5-15 Air Flow Control 5-15-1 Air Flow Distribution The fan at the rear of the scanner draws air into the scanner, through the foam filter, and pushes it through a flange that moves the air into a cavity on top of the card rack. Air holes in the bottom of this cavity allow the air to move down through the card rack. Air exits the card rack through...
Page 190
GE MEDICAL SYSTEMSPROPRIETARY TO GE D IRECTION 2294854-100, REVISION 3 LOGIQ™ 9 PROPRIETARYMANUAL 5-60 Section 5-16 - Service Platform 5-16-3 Global Service User Interface (GSUI) 5-16-3-1 Internationalization The user interface provided by the service platform is designed for GE personnel and as such is in English only. There is no multi-lingual capability built into the Service Interface. 5-16-3-2 Service Login Select the wrench icon in the status bar at the bottom of the scan display screen. This...