Page 321

Replacing Consumable Products321
9
9
9
9
9
9
9
9
9
9
9
9
4. Hold the photoconductor unit by the handle, and slowly lift it straight out of the printer.
w
Warning:
Be careful not to touch th e fuser, which is marked CAUTION 
HIGH TEMPERATURE , or the surrounding areas. If the 
printer has been in use, the fuser and the surrounding areas 
may be very hot.
5. Take the new photoconductor unit out of its package.
 

Page 322

322Replacing Consumable Products
6. Remove the protective material from the back side of the 
photoconductor unit.
c
Caution:
❏Be careful not to touch or scratch the surface of the drum 
and rollers.
❏ Avoid touching the drum, since oil from your skin may 
permanently damage its surface and affect print quality.
 

Page 323

Replacing Consumable Products323
9
9
9
9
9
9
9
9
9
9
9
9
7. Holding the handle firmly, lower the photoconductor unit into the printer, making sure the posts on the sides of the unit 
slide into the slots.
w
Warning:
Be careful not to touch th e fuser, which is marked CAUTION 
HIGH TEMPERATURE , or the surrounding areas. If the 
printer has been in use, the fuser and the surrounding areas 
may be very hot.
 

Page 324

324Replacing Consumable Products
8. Remove the protective material from the front side of the 
photoconductor unit.
9. Close covers D and A.
 

Page 325

Replacing Consumable Products325
9
9
9
9
9
9
9
9
9
9
9
9
Fuser Unit
Handling precautions
New :quote
 the i
nformation f
rom t
he
 s
imilar
 productAlways observe the following handling precautions when 
replacing the consumable products.
Do not touch the surface of the consumable product. Doing so 
may impair print quality.
w
Warning:
❏ The fuser unit can be very hot if the printer has been in use. 
Turn the printer off and wait for 30 minutes until the 
temperature has subsided befo re replacing the...

Page 326

326Replacing Consumable Products
1. Turn off the printer, and wait for 30 minutes until the 
temperature has subsided.
*OFF
2. Press the latch on cover B and open the cover.
*
 

Page 327

Replacing Consumable Products327
9
9
9
9
9
9
9
9
9
9
9
9
3. Unlock the lock levers on both sides of the fuser unit.
4. Lift the fuser unit out of the printer as shown below.
 

Page 328

328Replacing Consumable Products
5. Take the new fuser unit out of its package.
6. Hold the new fuser unit by the handles and lower it into the 
printer making sure that the posts on the unit slide into the 
notches of the lock levers.
 

Page 329

Replacing Consumable Products329
9
9
9
9
9
9
9
9
9
9
9
9
7. Push in on both sides of the fuser unit until the lock levers get to the lock positions.
Note:
Make sure that the lock levers are  completely back to the locked 
position marked Lock.
 

Page 330

330Replacing Consumable Products
8. Close cover B.
Transfer Unit
N
ew :quote
 t
he
 information
 from
 the s
imilar
 product
Handling precautions
Always observe the following handling precautions when 
replacing the consumable products.
Do not touch the surface of the consumable product. Doing so 
may impair print quality.
w
Warning:
❏ Do not dispose of the used consumable products in fire, as it 
may explode and cause injury. Dispose of it according to local 
regulations.
❏ Keep the consumable products...