49 Network Control Software Application-Software Control Click (register projector), then the projectors will be shown in the Monitor Window as shown below. Monitor window After changing the projector setting, you can save the data by clicking button or cancel by clicking button. Item Description Projector nameShow the Host name. (16 characters at most in ASCII.) IP Address Show the IP Address. Mask Show the Subnet Mask. Gateway Show the Gateway. MACShow up the MAC Address. (The default value can not be modified.) DHCPCapture IP address from network Server automatically. Note When DHCP setting is changed, in order to make the change effective AC power to the projector needs to be disconnected and reconnected. Modify The Projector Setting If you need to modify the projector’s setting, please move mouse cursor to the table on the left and press button on the column. The contents of the setting will appear on the right side table. < Graph 5 > : Register Table. < Table 1 > : Setting Windows.
50 Network Control Software Application-Software Control Sorting the projectors Projector can be sorted easily by clicking the monitor window title (Group Name) or (Projector Name). After registering, you can click button (Data single capture) in the tool bar or click button (Start Auto Scan) to update the status. NOTE While Auto Scan is running to update the status, the scroll bar for the window is grayed out and the hidden column can not be shown. Therefore before starting Auto Scan place the column in the window by using drag-drop or scroll bar in advance. Meaning of Status Icons The following table can be displayed by pressing " " Help button.
51 Network Control Software Application-Software Control Delete Select the registered projector in monitor window. Click mouse right key and select "Delete" to erase the registered projector data. < Graph 6 > : Register Table.
52 Network Control Software Application-Software Control Projector Setting (Setting for individual projector) Select the registered projector in monitor window. Click mouse right key and select "projector setting" to modify the registered projector data. After finishing the setting, you can save by clicking button or cancel by clicking button. < Graph 7 > : Register table. < Graph 8 > :Setting table.
53 Network Control Software Application-Software Control System Setting (Setting for all projectors) Click button (system setting) to modify system alert setting. Saving the setting < Graph 9 > Note: Alert setting in System Setting vs Projector Setting Whenever the " " Save button is pressed in System Setting, the value becomes effective for all the projectors registered. After this if the value in Projector Setting is changed and saved, the value becomes effective only for the projector.
54 Network Control Software Application-Software Control System Setting Monitor Item Description Lamp Timer Read lamp use time from projector. Air Filter Alert Read Air Filter Timer from projector. System Status/ Tempeture LevelRead System Status and Temperature from projector in Power On status. Input Source Read Input Source Selection from projector in Power ON status. < Table 2 > Default Setting Item Description Lamp Timer Alert (Hr.)Default Setting Includes 1000/1500/2000/3000 Hours. When Lamp Timer reaches alert target, window will show lamp timer in red color to remind user to replace the lamp. Air Filter Alert (Hr.)Default setting includes 500/1000/1500/2000/2500 Hours. When Filter Timer reaches alert target, window will show filter timer in red color to remind user to replace the filter. Auto Scan Timer (minutes)Auto Detect setting. Default setting includes 1/3/5/10 minutes; user can set the optimal default listed in Table 4. < Table 3 > Auto Scan Timer Projector Number (Sets) Timer Interval (Minutes) 1~25 1/3/5/10 26~50 3/5/10 51~100 5/10 101~255 10
55 Network Control Software Application-Software Control Saving the Project File Save the Configuration above as Project File by clicking the save button in the Tool bar in the Monitor window before closing Network Control Software. If it is not saved, all the configuration above will be lost. From next time after starting this Network Control Software the configuration can be recovered easily by opening the Project File.
56 Network Control Software Application-Software Control Link(Controlling Projector) Select the registered projector in monitor window. Click mouse right key and select "Link" to show the control panel table and the projector connecting status. < Graph 12 > : The control panel table
57 Network Control Software Application-Software Control Power Control Icon Name Power on Power off Input Source Icon Name Video S-Video Y, Pb, Pr / Y, Cb, Cr HDMI RGB 1 Change Input Source Function Key Icon Name Icon Name UpFreeze DownBlank LeftKeystone Correction + RightKeystone Correction - MenuIncrease Brightness Auto SyncDecrease Brightness MuteHigher Contrast
58 Network Control Software Application-Software Control Function Key Icon Name Lower Contrast Zoom In Zoom Out Volume Up Volume Down Projector Status Icon Name System Status Input Source Status Lamp Timer Air Filter Timer