EN-30 Appendix LED Indicator Messages ProjectorStatus Standby Lamp ignition failure Power on Lamp lifewarning Power off Over temperatureLED Type Power LED Lamp LED Color Status Color Status Meaning Green Amber Amber Amber Amber Amber Flashing Solid Solid Solid Solid Solid Off Off Green Amber Green Amber - - Solid Solid Flashing Flashing The projector is powered and ready. The projector system has some problems with its fan, so the projector cannot start up. The projector is operating normally. The lamp has reached its end of life and must be changed soon. The lamp will continue to operate until it fails. Change the lamp. If the lamp is off, then the ballast will become malfunction. The projector is shutting down. The fan motor is cooling the lamp for shutdown. Do not unplug the power cord or turn the power switch off before the lamp LED turns off. The fan motor will turn off when the lamp has cooled. Temperature is too high. The lamp will turn off.
EN-31 Compatibility Modes Computer: ModeResolution fH (kHz) fV (Hz) Timing 480P640 x 480 31.46 59.9 60Hz VGA 640 x 480 37.86 72.860Hz VGA 640 x 480 37.5 75.075Hz VGA 640 x 480 43.2 85.085Hz VGA 720 x 400 31.5 70.060Hz VGA 720 x 400 37.9 85.085Hz SVGA 800 x 600 35.1 56.256Hz SVGA 800 x 600 37.8 60.360Hz SVGA 800 x 600 48.0 72.172Hz SVGA 800 x 600 46.8 75.075Hz XGA 1024 x 768 48.3 60.060Hz XGA 1024 x 768 56.4 70.070Hz XGA 1024 x 768 60.0 75.075Hz XGA 1024 x 768 68.8 84.985Hz Mac16”832 x 624 49.7 74.5 60Hz SXGA1280 x 1024 63.98 60.0 60Hz SXGA1280 x 1024 79.9 75.0 75Hz 720P1280 x 720 45.0 60.0 60Hz XGA 1024 x 768 48.3 60.060Hz XGA 1024 x 768 60.2 75.060Hz SXGA 1152 x 870 68.6 75.0 75Hz SXGA 1152 x 864 67.5 75.0 75Hz Mac 480-66A 640 x 48035.0 66.7 66Hz Video: Signals Horizontal Frequency (kHz) Vertical Frequency (Hz) 480p31.5 kHz 60 Hz 720p45.0 kHz 60 Hz 1080i 33.7 kHz 30 Hz
EN-32 Troubleshooting Refer to the symptoms and measures listed below before sending the projector for repairs. If the problem persists, contact your dealer or service center. Please refer to “LED Indicator Messages” (p.30) as well.Symptom No power. Power goes out during use. No image appears on screen. Partial, scrolling or incorrectly displayed image. Image is unstable or flickering. Image has vertical flickering bar. Image is out of focus. Cause The AC power cord is not plugged in. The AC power cord is not connected to the projector. The lamp cover is loose. The temperature is too high. The ventilation holes are blocked. The projector is not turned on. The connections setup is not correctly. The connected devices are not functioning properly. Lens cap is not removed. “Blank” function is activated. The input signal is not supported by the projector. The signal timing of the display does not synchronize with the graphic card. The display data frequency does not match the frequency of your computer’s graphic card. The lens focus is not adjusted optimally. The projection distance is not within the projector’s supported range. Solution Plug in the AC power card. Connect the AC power cord to the projector correctly. Tighten the screws on the lamp cover. Unplug the AC power cord and wait for a short while, then turn the power back on. Place the projector so that the ventilation holes are not blocked. Turn the projector on. Check that all connections are setup correctly. Check that all connected devices are functioning properly. Remove the lens cap and turn the projector on. Cancel “Blank” function. Press remote control’s “Auto” button. Use “Phase” to correct it. Refer to Display section. Change the monitor color setting from your computer. Use “Tracking” to make an adjustment. Refer to Display section. Check and reconfigure the display mode of your graphic card to make it compatible with the product. Adjust the focus with the focus ring. Place the projector within the supported range.
EN-33 Symptom Remote control doesn’t work.Cause The battery could be weak. The remote control is not being used within the effective range. There are some obstructions between the remote control and projector. There are some fluorescent or other bright lights shining at the projector’s infrared remote sensor. Solution Replace with a new battery. Use the remote control within the effective range. Check that there are not obstructions between the remote control and projector. Check that there are not any fluorescent or other bright lights shining at the projector’s infrared remote sensor. Terminal : D-sub 9-pin SERVICE PORT CONNECTOR ---RX1ATX1---GND ------ --- Serial12345678 9 COMPUTER INPUT/COMPONENT INPUT TERMINAL (ANALOG) Terminal : Analog RGB (Mini D-sub 15 pin) 512341096781514131112 Red (R/Cr) Input / Output Ground (Horiz.sync.) Green (G/Y) Input / Output -----Blue (B/Cb) Input / Output Ground (Red)Ground (Green)Ground (Blue) 1 5 2 43 678 5V Horiz. sync. Input/Output (Composite H/V sync.) DSUB_PLUG DDC data----- Vert. sync.DDC clock 9 13 10 1211 1415 ---1 2 3 48976 5 Configurations of Ter minals
U.S.A. EIKI International, Inc. 30251 Esperanza Rancho Santa Margarita CA 92688-2132 U.S.A. Tel : 800-242-3454 (949)-457-0200 Fax : 800-457-3454 (949)-457-7878 E-Mail : [email protected] Deutschland & Österreich EIKI Deutschland GmbH Am Frauwald 12 65510 Idstein Deutschland Tel : 06126-9371-0 Fax : 06126-9371-14 E-Mail : [email protected] China EIKI (Shanghai) Co.,LTD 1. Dapu Road, Golden Magnolia Plaza #2109 Shanghai, 200023 China Tel : 86-21-5396-0088 Fax : 86-21-5396-031 E-Mail : [email protected] Canada EIKI CANADA -Eiki International, Inc. P.O. Box 156, 310 First St. - Unit 2, Midland, ON, L4R 4K8, Canada Tel : 800-563-3454 (705)-527-4084 Fax : 800-567-4069 (705)-527-4087 E-Mail : [email protected] Eastern Europe EIKI CZECH spol. s.r.o. Umelecka 15 170 00 Praha 7 Czech Republic Tel : +42 02 20570024 +42 02 20571413 Fax : +42 02 20571411 E-Mail : [email protected] Japan & Worldwide EIKI Industrial Company Limited. 4-12 Banzai-Cho, Kita-Ku, Osaka, 530-0028 Japan Tel : +81-6-6311-9479 Fax : +81-6-6311-8486 WorldWide Website http://www.eiki.com 03/2007 Eiki International, Inc.