1-11 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 1 Product Overview Catalyst 4507R-E Switch Table 1-5 Catalyst 4507R-E Switch Features Feature Description Chassis Seven horizontal slots. Slots are numbered from 1 (top) to 7 (bottom). Supervisor engines •Supports the following supervisor engines: –Supervisor Engine 8L-E1 –Supervisor Engine 8-E1 –Supervisor Engine 7L-E –Supervisor Engine 7-E NoteRefer to your software release notes for the minimum software release versions required to support the supervisor engines. •Supervisor engines must be installed in slot 3 and in slot 4. •Supervisor engine redundancy is supported in this chassis. NoteThe Catalyst 4507R-E switch supports 1+1 supervisor-engine redundancy for integrated resiliency. Redundant supervisor engines help minimize network downtime. With the support of stateful switchover (SSO), the secondary supervisor engine serves as a backup to immediately take over after a primary supervisor failure. During the switchover, Layer 2 links are maintained transparently without the need to renegotiate sessions. Modules •Supports up to five Catalyst 4500 series modules. •Some Catalyst 4500 series modules may: –Not be supported –Require that you install a specific supervisor engine –Have chassis slot restrictions –Require a specific software release level to operate •Check your software release notes for specific support information. Backplane 24 Gbps full duplex per slot (240 Gbps). Fan tray •The chassis supports a single hot-swappable fan tray. One fan tray model is available: –WS-X4597-E NoteThe Catalyst 4507R-E switch and the Catalyst 4507R+E switch use the same fan tray. •The fan tray contains eight individual fans. The individual fans are not field replaceable; you must replace the fan tray in the event of a fan failure. •Air is drawn in on the right side of the chassis and exhausted on the left side of the chassis. •Fan tray STATUS LED (located on the fan tray front panel) –Red—One or more individual fans have failed. –Green—Fan tray is operating normally.
1-12 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 1 Product Overview Catalyst 4507R-E Switch Ta b l e 1 - 6 lists the environmental and physical specifications of the Catalyst 4507R-E switch. Power supply •Supports one or two power supplies. The following power supplies are supported: –1000 W AC-input power supply (PWR-C45-1000AC) –1400 W AC-input power supply (PWR-C45-1400AC) –1300 W AC-input power supply (PWR-C45-1300ACV) –2800 W AC-input power supply (PWR-C45-2800ACV) –4200 W AC-input power supply (PWR-C45-4200ACV) –6000 W AC-input power supply (PWR-C45-6000ACV) –9000 W AC-input power supply (PWR-C45-9000ACV) –1400 W DC-input power supply, triple-input (PWR-C45-1400DC) –1400 W DC-input power supply with integrated PEM (PWR-C45-1400DC-P) –External AC power shelf (WS-P4502-1PSU) •All Catalyst 4500 series AC-input power supplies require single-phase source AC. •Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. •Single power supplies are installed in the left power supply bay. The second power supply is installed in the right power supply bay. NoteFor proper operation of the power supply OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. 1. To support Supervisor Engine 8-E and 8L-E, the Cisco Catalyst 4507R-E Switch chassis must have hardware revision 2.0 or higher. Note that the hardware revision is with reference to the chassis and not the supervisor engine. Table 1-5 Catalyst 4507R-E Switch Features (continued) Feature Description Table 1-6 Catalyst 4507R-E Switch Specifications Item Specification Temperature, ambient •Operating: 32° to 104°F (0° to 40°C) •Nonoperating and storage: –40° to 167°F (–40° to 75°C) Humidity (RH), ambient (noncondensing) •Operating: 10% to 90% •Nonoperating and storage: 5% to 95% Altitude, operating and nonoperating–196 to 6561 ft (–60 to 2000 m)
1-13 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 1 Product Overview Catalyst 4507R-E Switch Sound pressure level•One PS: 63.6 dBA at low speed and 68.3 dBA at full speed •Two PS: 65.4 dBA at low speed and 68.4 dBA at full speed Dimensions (H x W x D) and rack units (RU) •19.19 x 17.31 x 12.50 in. (48.74 x 43.97 x 31.70 cm) •11 RU Weight •44.5 lbs (20.19 kg) minimum weight •100 lbs (45.4 kg) maximum weight Airflow Chassis fan tray: Right to left Power supply fan: Front to back NoteWe recommend that you maintain a minimum air space of 6 inches (16 cm) between walls and the chassis air vents and a minimum horizontal separation of 12 inches (30.5 cm) between two chassis to prevent overheating. Table 1-6 Catalyst 4507R-E Switch Specifications (continued) Item Specification
1-14 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 1 Product Overview Catalyst 4510R-E Switch Catalyst 4510R-E Switch The Catalyst 4510R-E switch is a 10-slot horizontal chassis supporting redundant power supplies, redundant supervisor engines, and slots for up to nine modules. Figure 1-4 shows a front view of the Catalyst 4510R-E switch with the chassis major features identified. Figure 1-4 Catalyst 4510R-E Switch Chassis (Front View) Ta b l e 1 - 7 describes the features of the Catalyst 4510R-E switch. 1Fan tray assembly3Supervisor engines (primary in slot 5 and secondary in slot 6) 2Switching modules (slots 1–4 and 7–10)4Power supplies RE MO VE LABEL FOR SYS TE M GROUNDMinimum Cat4500 Software Requi rement V ersi on: IO S: 12.2(37) SG 1 2231953 4506 2 3 4 1 S TAT U S12 1 1 10 9 8 7 6 5 4 3 2 114 1 316 1528 27 26 25 24 23 22 21 20 19 1 8 1730 2 932 3144 43 42 4 1 40 39 38 37 36 35 34 3 34 6 4548 4 7 10/ 100BAS E- TX E T HERN ETM UL T I-S PE ED G IG ABI T E T HERN ET S WIT CHING MODU L E S TAT U S12 1 1 10 9 8 7 6 5 4 3 2 114 1 316 1528 27 26 25 24 23 22 21 20 19 18 1730 2 932 3144 43 42 4 1 40 39 38 37 36 35 34 3 34 6 4548 4 7 10/ 100BAS E- TX E T HERN ETM UL T I-S PE ED G IG ABI T E T HERN ET S WIT CHING MODU L E
1-15 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 1 Product Overview Catalyst 4510R-E Switch Table 1-7 Catalyst 4510R-E Switch Features Feature Description Chassis Ten horizontal slots. Slots are numbered from 1 (top) to 10 (bottom). Supervisor engines •Supports the following supervisor engines: –Supervisor Engine 8-E –Supervisor Engine 7-E NoteRefer to your software release notes for the minimum software release versions required to support the supervisor engines. •Supervisor engines must be installed in slot 5 or in slot 6. •Supervisor engine redundancy is supported in this chassis. NoteThe Catalyst 4510R-E switch supports 1+1 supervisor-engine redundancy for integrated resiliency. With the support of stateful switchover (SSO), the secondary supervisor engine serves as a backup to immediately take over after a primary supervisor failure. During the switchover, Layer 2 links are maintained transparently without the need to renegotiate sessions. Modules •Supports up to eight Catalyst 4500 series modules. •Some Catalyst 4500 series modules may: –Not be supported –Require that you install a specific supervisor engine –Have chassis slot restrictions –Require a specific software release level to operate •Check your software release notes for specific support information. Backplane 24 Gbps full duplex per slot on five slots, plus 12 Gbps full duplex per slot on three slots (276 Gbps) with Supervisor Engine 6-E Fan tray •The chassis supports one hot-swappable fan tray. One fan tray model is available: –WS-X4582-E (located on the fan tray front panel) NoteThe Catalyst 4510R-E and the Catalyst 4510R+E switches use the same fan tray. •The fan tray contains ten individual fans. The individual fans are not field replaceable; you must replace the fan tray in the event of a fan failure. •Air is drawn in on the right side of the chassis and exhausted on the left side of the chassis. •Fan tray STATUS LED (located on the fan tray front panel) –Red—One or more individual fans have failed. –Green—Fan tray is operating normally.
1-16 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 1 Product Overview Catalyst 4510R-E Switch Power supply•Supports one or two power supplies. The following power supplies are supported: –1000 W AC-input power supply (PWR-C45-1000AC) –1400 W AC-input power supply (PWR-C45-1400AC) –1300 W AC-input power supply (PWR-C45-1300ACV) –2800 W AC-input power supply (PWR-C45-2800ACV) –4200 W AC-input power supply (PWR-C45-4200ACV) –6000 W AC-input power supply (PWR-C45-6000ACV) –9000 W AC-input power supply (PWR-C45-9000ACV) –1400 W DC-input power supply, triple-input (PWR-C45-1400DC) –1400 W DC-input power supply with integrated PEM (PWR-C45-1400DC-P) –External AC power shelf (WS-P4502-1PSU) •All Catalyst 4500 series AC-input power supplies require single-phase source AC. •Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. •Single power supplies are installed in the left power supply bay. The second power supply is installed in the right power supply bay. NoteFor proper operation of the power supply OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. Table 1-7 Catalyst 4510R-E Switch Features (continued) Feature Description
1-17 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 1 Product Overview Catalyst 4510R-E Switch Ta b l e 1 - 8 lists the environmental and physical specifications of the Catalyst 4510R-E switch. Table 1-8 Catalyst 4510R-E Switch Specifications Item Specification Temperature, ambient •Operating: 32° to 104°F (0° to 40°C) •Nonoperating and storage: –40° to 167°F (–40° to 75°C) Humidity (RH), ambient (noncondensing) •Operating: 10% to 90% •Nonoperating and storage: 5% to 95% Altitude, operating –196 to 6561 ft (–60 to 2000 m) Sound pressure level •One PS—63.6 dBA at low speed and 68.3 dBA at full speed •Two PS—65.4 dBA at low speed and 68.4 dBA at full speed Dimensions (H x W x D) and rack units (RU) •24.35 x 17.31 x 12.50 in. (61.84 x 43.97 x 31.70 cm) •14 RU Weight •54.5 lbs (24.77 kg) minimum •108 lbs (45.4 kg) maximum Airflow •Chassis fan tray: Right to left •Power supply fan: Front to back NoteWe recommend that you maintain a minimum air space of 6 inches (16 cm) between walls and the chassis air vents and a minimum horizontal separation of 12 inches (30.5 cm) between two chassis to prevent overheating.
1-18 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 1 Product Overview Catalyst 4507R+E Switch Catalyst 4507R+E Switch The Catalyst 4507R+E switch is a 7-slot horizontal chassis supporting redundant power supplies, redundant supervisor engines, and slots for up to five modules. Figure 1-5 shows a front view of the Catalyst 4507R+E switch with the chassis major features identified. Figure 1-5 Catalyst 4507R+E Switch Chassis Ta b l e 1 - 9 describes the features of the Catalyst 4507R+E switch. 1Fan tray3Supervisor engines (primary in slot 3 and secondary in slot 4) 2Switching modules (slots 1, 2, 5, 6, 7)4Power supplies 279246 +E S er i esRE MO VE LABEL FO R SYS TEM G ROUNDMinimum Cat45 00 Software Requi rement V ersi on: I OS: 12.2(37 )SG4506 +E Series 2 3 4 1
1-19 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 1 Product Overview Catalyst 4507R+E Switch Table 1-9 Catalyst 4507R+E Switch Features Feature Description Chassis Seven horizontal slots. Slots are numbered from 1 (top) to 7 (bottom). Supervisor engines •Supports the following supervisor engines: –Supervisor Engine 9-E –Supervisor Engine 8L-E –Supervisor Engine 8-E –Supervisor Engine 7L-E –Supervisor Engine 7-E NoteRefer to your software release notes for the minimum software release versions required to support the supervisor engines. •Supervisor engines must be installed in slot 3 or in slot 4. •Supervisor engine redundancy is supported in this chassis. NoteThe Catalyst 4507R+E switch supports 1+1 supervisor-engine redundancy. With the support of stateful switchover (SSO), the secondary supervisor engine serves as a backup to immediately take over after a primary supervisor failure. During the switchover, Layer 2 links are maintained transparently without the need to renegotiate sessions. Modules •Supports up to five Catalyst 4500 series modules. •Some Catalyst 4500 series modules may: –Not be supported –Require that you install a specific supervisor engine –Have chassis slot restrictions –Require a specific software release level to operate •Check your software release notes for specific support information. Backplane 48 Gbps full duplex per slot Fan tray •The chassis supports a single hot-swappable fan tray. One fan tray model is available: –WS-X4597+E •The fan tray contains eight individual fans. The individual fans are not field replaceable; you must replace the fan tray in the event of a fan failure. •Air is drawn in on the right side of the chassis and exhausted on the left side of the chassis. •Fan tray STATUS LED (located on the fan tray front panel) –Red—One or more individual fans have failed. –Green—Fan tray is operating normally.
1-20 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 1 Product Overview Catalyst 4507R+E Switch Power supply•Supports one or two power supplies. The following power supplies are supported: –1000 W AC-input power supply (PWR-C45-1000AC) –1400 W AC-input power supply (PWR-C45-1400AC) –1300 W AC-input power supply (PWR-C45-1300ACV) –2800 W AC-input power supply (PWR-C45-2800ACV) –4200 W AC-input power supply (PWR-C45-4200ACV) –6000 W AC-input power supply (PWR-C45-6000ACV) –9000 W AC-input power supply (PWR-C45-9000ACV) –1400 W DC-input power supply, triple-input (PWR-C45-1400DC) –1400 W DC-input power supply with integrated PEM (PWR-C45-1400DC-P) –External AC power shelf (WS-P4502-1PSU) •All Catalyst 4500 series AC-input power supplies require single-phase source AC. •Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. •Single power supplies are installed in the left power supply bay. The second power supply is installed in the right power supply bay. NoteFor proper operation of the power supply OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. Table 1-9 Catalyst 4507R+E Switch Features (continued) Feature Description