Home > Cisco > Ethernet Switch > Cisco 4507re Manual

Cisco 4507re Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Cisco 4507re Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 53 Cisco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							  
    1-11
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Chapter 1      Product Overview
    Catalyst 4507R-E Switch
    Table 1-5 Catalyst 4507R-E Switch Features
    Feature Description
    Chassis Seven horizontal slots. Slots are numbered from 1 (top) to 7 (bottom).
    Supervisor engines
    •Supports the following supervisor engines:
    –Supervisor Engine 8L-E1
    –Supervisor Engine 8-E1 
    –Supervisor Engine 7L-E
    –Supervisor Engine 7-E
    NoteRefer to your software release notes for the minimum software 
    release versions required to support the supervisor engines.
    •Supervisor engines must be installed in slot 3 and in slot 4.
    •Supervisor engine redundancy is supported in this chassis.
    NoteThe Catalyst 4507R-E switch supports 1+1 supervisor-engine 
    redundancy for integrated resiliency. Redundant supervisor engines 
    help minimize network downtime. With the support of stateful 
    switchover (SSO), the secondary supervisor engine serves as a 
    backup to immediately take over after a primary supervisor failure. 
    During the switchover, Layer 2 links are maintained transparently 
    without the need to renegotiate sessions. 
    Modules
    •Supports up to five Catalyst 4500 series modules.
    •Some Catalyst 4500 series modules may:
    –Not be supported
    –Require that you install a specific supervisor engine
    –Have chassis slot restrictions
    –Require a specific software release level to operate
    •Check your software release notes for specific support information.
    Backplane 24 Gbps full duplex per slot (240 Gbps).
    Fan tray
    •The chassis supports a single hot-swappable fan tray. One fan tray model 
    is available:
    –WS-X4597-E
    NoteThe Catalyst 4507R-E switch and the Catalyst 4507R+E switch use 
    the same fan tray.
    •The fan tray contains eight individual fans. The individual fans are not 
    field replaceable; you must replace the fan tray in the event of a fan 
    failure.
    •Air is drawn in on the right side of the chassis and exhausted on the left 
    side of the chassis.
    •Fan tray STATUS LED (located on the fan tray front panel)
    –Red—One or more individual fans have failed.
    –Green—Fan tray is operating normally. 
    						
    							  
    1-12
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Chapter 1      Product Overview
    Catalyst 4507R-E Switch
    Ta b l e 1 - 6 lists the environmental and physical specifications of the Catalyst 4507R-E switch. Power supply
    •Supports one or two power supplies. The following power supplies are 
    supported:
    –1000 W AC-input power supply (PWR-C45-1000AC)
    –1400 W AC-input power supply (PWR-C45-1400AC)
    –1300 W AC-input power supply (PWR-C45-1300ACV)
    –2800 W AC-input power supply (PWR-C45-2800ACV)
    –4200 W AC-input power supply (PWR-C45-4200ACV)
    –6000 W AC-input power supply (PWR-C45-6000ACV)
    –9000 W AC-input power supply (PWR-C45-9000ACV)
    –1400 W DC-input power supply, triple-input (PWR-C45-1400DC)
    –1400 W DC-input power supply with integrated PEM 
    (PWR-C45-1400DC-P)
    –External AC power shelf (WS-P4502-1PSU)
    •All Catalyst 4500 series AC-input power supplies require single-phase 
    source AC. 
    •Source AC can be out of phase between multiple power supplies or 
    multiple AC-power plugs on the same power supply because all AC 
    power supply inputs are isolated.
    •Single power supplies are installed in the left power supply bay. The 
    second power supply is installed in the right power supply bay.
    NoteFor proper operation of the power supply OUTPUT FAIL LED, 
    systems with single power supplies must be configured with a 
    minimum of one fan tray and one supervisor engine. Systems with 
    dual power supplies must have a minimum configuration of one fan 
    tray, one supervisor engine, and one additional module. Failure to 
    meet these minimum configuration requirements can cause a false 
    power supply output fail signal.
    1. To support Supervisor Engine 8-E and 8L-E, the Cisco Catalyst 4507R-E Switch chassis must have hardware revision 2.0 or higher. 
    Note that the hardware revision is with reference to the chassis and not the supervisor engine.
    Table 1-5 Catalyst 4507R-E Switch Features (continued)
    Feature Description
    Table 1-6 Catalyst 4507R-E Switch Specifications
    Item Specification
    Temperature, ambient
    •Operating: 32° to 104°F (0° to 40°C)
    •Nonoperating and storage: –40° to 167°F (–40° to 75°C)
    Humidity (RH), ambient 
    (noncondensing)
    •Operating: 10% to 90%
    •Nonoperating and storage: 5% to 95%
    Altitude,
    operating and nonoperating–196 to 6561 ft (–60 to 2000 m) 
    						
    							  
    1-13
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Chapter 1      Product Overview
    Catalyst 4507R-E Switch
    Sound pressure level•One PS: 63.6 dBA at low speed and 68.3 dBA at full speed
    •Two PS: 65.4 dBA at low speed and 68.4 dBA at full speed
    Dimensions (H x W x D) and 
    rack units (RU)
    •19.19 x 17.31 x 12.50 in. (48.74 x 43.97 x 31.70 cm)
    •11 RU
    Weight
    •44.5 lbs (20.19 kg) minimum weight 
    •100 lbs (45.4 kg) maximum weight
    Airflow Chassis fan tray: Right to left
    Power supply fan: Front to back
    NoteWe recommend that you maintain a minimum air space of 6 inches 
    (16 cm) between walls and the chassis air vents and a minimum 
    horizontal separation of 12 inches (30.5 cm) between two chassis to 
    prevent overheating.
    Table 1-6 Catalyst 4507R-E Switch Specifications (continued)
    Item Specification 
    						
    							  
    1-14
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Chapter 1      Product Overview
    Catalyst 4510R-E Switch
    Catalyst 4510R-E Switch
    The Catalyst 4510R-E switch is a 10-slot horizontal chassis supporting redundant power supplies, 
    redundant supervisor engines, and slots for up to nine modules. Figure 1-4 shows a front view of the 
    Catalyst 4510R-E switch with the chassis major features identified.
    Figure 1-4 Catalyst 4510R-E Switch Chassis (Front View)
    Ta b l e 1 - 7 describes the features of the Catalyst 4510R-E switch.  1Fan tray assembly3Supervisor engines (primary in slot 5 and 
    secondary in slot 6)
    2Switching modules (slots 1–4 and 7–10)4Power supplies
    RE
    MO
    VE 
    LABEL 
    FOR
    SYS
    TE
    M 
    GROUNDMinimum 
    Cat4500 Software Requi
    rement
    V
    ersi
    on: IO
    S: 12.2(37)
    SG
    1
    2231953
    4506
    2
    3
    4
    1
    S
    TAT
    U
    S12 1
    1 10 9 8 7 6 5 4 3 2 114 1
    316 1528 27 26 25 24 23 22 21 20 19 1
    8 1730 2
    932 3144 43 42 4
    1 40 39 38 37 36 35 34 3
    34
    6 4548 4
    7
    10/
    100BAS
    E-
    TX
    E
    T
    HERN
    ETM
    UL
    T
    I-S
    PE
    ED
    G
    IG
    ABI
    T E
    T
    HERN
    ET
    S
    WIT
    CHING 
    MODU
    L
    E
    S
    TAT
    U
    S12 1
    1 10 9 8 7 6 5 4 3 2 114 1
    316 1528 27 26 25 24 23 22 21 20 19 18 1730 2
    932 3144 43 42 4
    1 40 39 38 37 36 35 34 3
    34
    6 4548 4
    7
    10/
    100BAS
    E-
    TX
    E
    T
    HERN
    ETM
    UL
    T
    I-S
    PE
    ED
    G
    IG
    ABI
    T E
    T
    HERN
    ET
    S
    WIT
    CHING 
    MODU
    L
    E 
    						
    							  
    1-15
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Chapter 1      Product Overview
    Catalyst 4510R-E Switch
    Table 1-7 Catalyst 4510R-E Switch Features
    Feature Description
    Chassis Ten horizontal slots. Slots are numbered from 1 (top) to 10 (bottom).
    Supervisor engines
    •Supports the following supervisor engines:
    –Supervisor Engine 8-E
    –Supervisor Engine 7-E
    NoteRefer to your software release notes for the minimum software 
    release versions required to support the supervisor engines.
    •Supervisor engines must be installed in slot 5 or in slot 6.
    •Supervisor engine redundancy is supported in this chassis.
    NoteThe Catalyst 4510R-E switch supports 1+1 supervisor-engine 
    redundancy for integrated resiliency. With the support of stateful 
    switchover (SSO), the secondary supervisor engine serves as a 
    backup to immediately take over after a primary supervisor failure. 
    During the switchover, Layer 2 links are maintained transparently 
    without the need to renegotiate sessions. 
    Modules
    •Supports up to eight Catalyst 4500 series modules.
    •Some Catalyst 4500 series modules may:
    –Not be supported
    –Require that you install a specific supervisor engine
    –Have chassis slot restrictions
    –Require a specific software release level to operate
    •Check your software release notes for specific support information.
    Backplane 24 Gbps full duplex per slot on five slots, plus 12 Gbps full duplex per slot 
    on three slots (276 Gbps) with Supervisor Engine 6-E 
    Fan tray
    •The chassis supports one hot-swappable fan tray. One fan tray model is 
    available:
    –WS-X4582-E (located on the fan tray front panel)
    NoteThe Catalyst 4510R-E and the Catalyst 4510R+E switches use the 
    same fan tray.
    •The fan tray contains ten individual fans. The individual fans are not 
    field replaceable; you must replace the fan tray in the event of a fan 
    failure.
    •Air is drawn in on the right side of the chassis and exhausted on the left 
    side of the chassis.
    •Fan tray STATUS LED (located on the fan tray front panel)
    –Red—One or more individual fans have failed.
    –Green—Fan tray is operating normally. 
    						
    							  
    1-16
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Chapter 1      Product Overview
    Catalyst 4510R-E Switch
    Power supply•Supports one or two power supplies. The following power supplies are 
    supported:
    –1000 W AC-input power supply (PWR-C45-1000AC)
    –1400 W AC-input power supply (PWR-C45-1400AC)
    –1300 W AC-input power supply (PWR-C45-1300ACV)
    –2800 W AC-input power supply (PWR-C45-2800ACV)
    –4200 W AC-input power supply (PWR-C45-4200ACV)
    –6000 W AC-input power supply (PWR-C45-6000ACV)
    –9000 W AC-input power supply (PWR-C45-9000ACV)
    –1400 W DC-input power supply, triple-input (PWR-C45-1400DC)
    –1400 W DC-input power supply with integrated PEM 
    (PWR-C45-1400DC-P)
    –External AC power shelf (WS-P4502-1PSU)
    •All Catalyst 4500 series AC-input power supplies require single-phase 
    source AC. 
    •Source AC can be out of phase between multiple power supplies or 
    multiple AC-power plugs on the same power supply because all AC 
    power supply inputs are isolated.
    •Single power supplies are installed in the left power supply bay. The 
    second power supply is installed in the right power supply bay.
    NoteFor proper operation of the power supply OUTPUT FAIL LED, 
    systems with single power supplies must be configured with a 
    minimum of one fan tray and one supervisor engine. Systems with 
    dual power supplies must have a minimum configuration of one fan 
    tray, one supervisor engine, and one additional module. Failure to 
    meet these minimum configuration requirements can cause a false 
    power supply output fail signal.
    Table 1-7 Catalyst 4510R-E Switch Features (continued)
    Feature Description 
    						
    							  
    1-17
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Chapter 1      Product Overview
    Catalyst 4510R-E Switch
    Ta b l e 1 - 8 lists the environmental and physical specifications of the Catalyst 4510R-E switch.
    Table 1-8 Catalyst 4510R-E Switch Specifications
    Item Specification
    Temperature, ambient
    •Operating: 32° to 104°F (0° to 40°C)
    •Nonoperating and storage: –40° to 167°F (–40° to 75°C)
    Humidity (RH), ambient 
    (noncondensing)
    •Operating: 10% to 90%
    •Nonoperating and storage: 5% to 95%
    Altitude, operating –196 to 6561 ft (–60 to 2000 m)
    Sound pressure level
    •One PS—63.6 dBA at low speed and 68.3 dBA at full speed
    •Two PS—65.4 dBA at low speed and 68.4 dBA at full speed
    Dimensions (H x W x D) and 
    rack units (RU)
    •24.35 x 17.31 x 12.50 in. (61.84 x 43.97 x 31.70 cm)
    •14 RU
    Weight
    •54.5 lbs (24.77 kg) minimum
    •108 lbs (45.4 kg) maximum
    Airflow
    •Chassis fan tray: Right to left
    •Power supply fan: Front to back
    NoteWe recommend that you maintain a minimum air space of 6 inches 
    (16 cm) between walls and the chassis air vents and a minimum 
    horizontal separation of 12 inches (30.5 cm) between two chassis to 
    prevent overheating. 
    						
    							  
    1-18
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Chapter 1      Product Overview
    Catalyst 4507R+E Switch
    Catalyst 4507R+E Switch
    The Catalyst 4507R+E switch is a 7-slot horizontal chassis supporting redundant power supplies, 
    redundant supervisor engines, and slots for up to five modules. Figure 1-5 shows a front view of the 
    Catalyst 4507R+E switch with the chassis major features identified.
    Figure 1-5 Catalyst 4507R+E Switch Chassis
    Ta b l e 1 - 9 describes the features of the Catalyst 4507R+E switch.  1Fan tray3Supervisor engines (primary in slot 3 and 
    secondary in slot 4)
    2Switching modules (slots 1, 2, 5, 6, 7)4Power supplies
    279246
    +E S
    er
    i
    esRE
    MO
    VE LABEL FO
    R
    SYS
    TEM G
    ROUNDMinimum Cat45
    00 Software
     Requi
    rement
    V
    ersi
    on: I
    OS: 12.2(37
    )SG4506
    +E Series
    2
    3
    4
    1 
    						
    							  
    1-19
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Chapter 1      Product Overview
    Catalyst 4507R+E Switch
    Table 1-9 Catalyst 4507R+E Switch Features
    Feature Description
    Chassis Seven horizontal slots. Slots are numbered from 1 (top) to 7 (bottom).
    Supervisor engines
    •Supports the following supervisor engines:
    –Supervisor Engine 9-E
    –Supervisor Engine 8L-E 
    –Supervisor Engine 8-E 
    –Supervisor Engine 7L-E
    –Supervisor Engine 7-E
    NoteRefer to your software release notes for the minimum software 
    release versions required to support the supervisor engines.
    •Supervisor engines must be installed in slot 3 or in slot 4.
    •Supervisor engine redundancy is supported in this chassis.
    NoteThe Catalyst 4507R+E switch supports 1+1 supervisor-engine 
    redundancy. With the support of stateful switchover (SSO), the 
    secondary supervisor engine serves as a backup to immediately take 
    over after a primary supervisor failure. During the switchover, 
    Layer 2 links are maintained transparently without the need to 
    renegotiate sessions. 
    Modules
    •Supports up to five Catalyst 4500 series modules.
    •Some Catalyst 4500 series modules may:
    –Not be supported
    –Require that you install a specific supervisor engine
    –Have chassis slot restrictions
    –Require a specific software release level to operate
    •Check your software release notes for specific support information.
    Backplane 48 Gbps full duplex per slot 
    Fan tray
    •The chassis supports a single hot-swappable fan tray. One fan tray model 
    is available:
    –WS-X4597+E
    •The fan tray contains eight individual fans. The individual fans are not 
    field replaceable; you must replace the fan tray in the event of a fan 
    failure.
    •Air is drawn in on the right side of the chassis and exhausted on the left 
    side of the chassis.
    •Fan tray STATUS LED (located on the fan tray front panel)
    –Red—One or more individual fans have failed.
    –Green—Fan tray is operating normally. 
    						
    							  
    1-20
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Chapter 1      Product Overview
    Catalyst 4507R+E Switch
    Power supply•Supports one or two power supplies. The following power supplies are 
    supported:
    –1000 W AC-input power supply (PWR-C45-1000AC)
    –1400 W AC-input power supply (PWR-C45-1400AC)
    –1300 W AC-input power supply (PWR-C45-1300ACV)
    –2800 W AC-input power supply (PWR-C45-2800ACV)
    –4200 W AC-input power supply (PWR-C45-4200ACV)
    –6000 W AC-input power supply (PWR-C45-6000ACV)
    –9000 W AC-input power supply (PWR-C45-9000ACV)
    –1400 W DC-input power supply, triple-input (PWR-C45-1400DC)
    –1400 W DC-input power supply with integrated PEM 
    (PWR-C45-1400DC-P)
    –External AC power shelf (WS-P4502-1PSU)
    •All Catalyst 4500 series AC-input power supplies require single-phase 
    source AC. 
    •Source AC can be out of phase between multiple power supplies or 
    multiple AC-power plugs on the same power supply because all AC 
    power supply inputs are isolated.
    •Single power supplies are installed in the left power supply bay. The 
    second power supply is installed in the right power supply bay.
    NoteFor proper operation of the power supply OUTPUT FAIL LED, 
    systems with single power supplies must be configured with a 
    minimum of one fan tray and one supervisor engine. Systems with 
    dual power supplies must have a minimum configuration of one fan 
    tray, one supervisor engine, and one additional module. Failure to 
    meet these minimum configuration requirements can cause a false 
    power supply output fail signal.
    Table 1-9 Catalyst 4507R+E Switch Features (continued)
    Feature Description 
    						
    All Cisco manuals Comments (0)

    Related Manuals for Cisco 4507re Manual