    							A-3
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Appendix A      Power Supply Specifications
      1000 W AC-Input Power Supply
    1000 W AC-Input Power Supply Specifications
    Ta b l e A - 1 lists the specifications for the 1000 W AC-input power supply.
    Table A-1 1000 W AC-Input Power Supply Specifications
    Item Specification
    AC-input type Autoranging input with power factor correction (PFC)
    NotePower factor correction is a standard feature on all Catalyst 4500 
    E-series AC-input power supplies. PFC reduces the reactive 
    component in the source AC current allowing higher power 
    factors (typically 99 percent or better) and lower harmonic 
    current components.
    AC-input voltage
    •Low-line (120 VAC nominal)—85 VAC (min) to 132 VAC (max)
    •High-line (230 VAC nominal)—170 VAC (min) to 264 VAC (max)
    AC-input current
    •12 A @ 120 VAC
    •5A @ 240VAC
    AC-input frequency 50/60 Hz (nominal) (±3 Hz for full range)
    Branch circuit requirement Each chassis power supply should have its own dedicated, fused-branch 
    circuit:
    •For North America—15 A or 20 A
    •For International—Circuits sized to local and national codes
    •All Catalyst 4500 E-series AC-input power supplies require 
    single-phase source AC.
    •All AC power supply inputs are fully isolated.
    –Source AC can be out of phase between multiple power supplies 
    in the same chassis, which means that PS1 can be operating 
    from phase A and PS2 can be operating from phase B.
    –For high-line operation, the power supply operates with the hot 
    conductor wired to a source AC phase and the neutral conductor 
    wired either to ground or to another source AC phase as long as 
    the net input voltage is in the range of 170 to 264 VAC.
    –Source AC can be out of phase between AC inputs on power 
    supplies that are equipped with multiple AC inputs, which 
    means that power cord 1 can be plugged into phase A and 
    power cord 2 can be plugged into phase B. 
    						
    							A-4
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Appendix A      Power Supply Specifications
      1000 W AC-Input Power Supply
    Ta b l e A - 2 lists the 1000 W AC-input power supply LEDs and their meanings.
    1000 W Power Supply AC Power Cords
    Ta b l e A - 3 lists the specifications for the regional AC power cords that are available for the 1000 W 
    AC-input power supply.
    NoteAll 1000 W power supply AC power cords have an IEC60320/C15 appliance plug at one end. Power supply output 
    capacity 1050 W plus 40 W (fan)
    Power supply output 83.4 A @ +12 VDC
    12.2 A @ +3.3 VDC
    Output holdup time 20 ms minimum
    Maximum kVA rating 1.32 kVA
    Max heat dissipation 943 BTUs/hr
    Minimum software 
    requirementCisco IOS Release 12.1(12c)EW
    Power over Ethernet Not supported
    1
    1. A Catalyst 4503 with a Catalyst 4500 series Supervisor Engine II-Plus TS and a 1000 W power supply will be able to provide 
    158.4 W of Power over Ethernet (PoE) to ports on the supervisor engine. Switching modules in the other slots will not be able 
    to provide PoE.
    Table A-1 1000 W AC-Input Power Supply Specifications (continued)
    Item Specification
    Table A-2 1000 W AC-Input Power Supply LEDs
    LED Meaning
    INPUT OK
    •Green—Source AC voltage is OK. (Input voltage is 85 VAC or 
    greater.)
    •Off—Source AC voltage falls below 70 VAC, is not present, or the 
    power supply is turned off.
    FAN OK
    •Green—Power supply fan is operating properly.
    •Off—Power supply fan failure is detected.
    OUTPUT FAIL
    •Red—Problem with one or more of the DC-output voltages of the 
    power supply is detected.
    •Off—DC-output voltage with acceptable margins. 
    						
    							A-5
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Appendix A      Power Supply Specifications
      1000 W AC-Input Power Supply
    Table A-3 1000 W AC Power Supply Power Cords
    LocalePower Cord Part 
    Number Length Cordset Rating Plug Type
    Japan, North 
    America CAB-US515-C15-US= 
    (was CAB-7KAC=)8.2 ft (2.5 m) 15 A, 125 VAC NEMA 5-15P
    Australia, 
    New ZealandCAB-AS3112-C15-AU= 
    (was CAB-7ACA=)8.2 ft (2.5 m) 15 A, 250 VAC AS/NZS 3112-1993
    Europe (except 
    Italy)CAB-CEE77-C15-EU= 
    (was CAB-7ACE=)8.2 ft (2.5 m) 16 A, 250 VAC CEE 7/7
    Italy CAB-C2316-C15-IT= 
    (was CAB-7ACI=)8.2 ft (2.5 m) 16 A, 250 VAC 1/3/16 CEI 23-16
    United 
    KingdomCAB-BS1363-C15-UK= 
    (was CAB-7ACU=)8.2 ft (2.5 m) 13 A, 250 VAC BS 1363/A
    1
    1. Plug contains a 13 A fuse.
    Argentina CAB-IR2073-C15-AR= 
    (was CAB-7KACR=)8.2 ft (2.5 m) 10 A, 250 VAC IRAM 2073
    120354
    120356
    120357
    120358
    120359
    120356 
    						
    							A-6
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Appendix A      Power Supply Specifications
      1300 W AC-Input Power Supply
    1300 W AC-Input Power Supply
    The 1300 W AC-input power supply (PWR-C45-1300ACV), shown in Figure A-2, is supported in the 
    following Catalyst 4500 E-series switches:
    •Catalyst 4503-E
    •Catalyst 4506-E
    •Catalyst 4507R-E
    •Catalyst 4507R+E
    •Catalyst 4510R-E (the 1300 W AC-input power supply can be installed in the Catalyst 4510R-E 
    switch chassis; however power management is required)
    •Catalyst 4510R+E (the 1300 W AC-input power supply can be installed in the Catalyst 4510R+E 
    switch chassis; however power management is required)
    Figure A-2 1300 W AC-Input Power Supply Features
    1300 W AC-Input Power Supply Specifications
    Ta b l e A - 4 lists the specifications for the 1300 W AC-input power supply. 1AC-input receptacle3Captive installation screws
    2Power on/off switch
    2313751
    2
    3 
    						
    							A-7
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Appendix A      Power Supply Specifications
      1300 W AC-Input Power Supply
    Table A-4 1300 W AC-Input Power Supply Specifications
    Item Specification
    AC-input type Autoranging input with power factor corrector
    NotePower factor correction is a standard feature on all Catalyst 4500 
    E-series AC-input power supplies. PFC reduces the reactive 
    component in the source AC current allowing higher power 
    factors (typically 99 percent or better) and lower harmonic 
    current components.
    AC-input voltage
    •Low-line (120 VAC nominal)—85 VAC (min) to 132 VAC (max)
    •High-line (230 VAC nominal)—170 VAC (min) to 264 VAC (max)
    AC-input current
    •16 A @ 100 VAC
    •7A @ 240VAC
    AC-input frequency 50/60 Hz (nominal) (±3 Hz for full range)
    Branch circuit requirement Each chassis power supply should have its own dedicated, fused-branch 
    circuit:
    •For North America—15 A or 20 A
    •For International—Circuits sized to local and national codes
    •All Catalyst 4500 E-series AC-input power supplies require 
    single-phase source AC.
    •All AC power supply inputs are fully isolated.
    –Source AC can be out of phase between multiple power supplies 
    in the same chassis, which means that PS1 can be operating 
    from phase A and PS2 can be operating from phase B.
    –For high-line operation, the power supply operates with the hot 
    conductor wired to a source AC phase and the neutral conductor 
    wired either to ground or to another source AC phase as long as 
    the net input voltage is in the range of 170 to 264 VAC.
    –Source AC can be out of phase between AC inputs on power 
    supplies that are equipped with multiple AC inputs, which 
    means that power cord 1 can be plugged into phase A and 
    power cord 2 can be plugged into phase B.
    Power supply output 
    capacity
    •1300 W maximum 
    •1050 W+ 40 W redundant mode (data)
    •1667 W maximum in combined mode (data)
    •800 W maximum each in redundant mode (PoE)
    •1333 W maximum in combined mode (PoE) 
    						
    							A-8
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Appendix A      Power Supply Specifications
      1300 W AC-Input Power Supply
    Ta b l e A - 5 lists the 1300 W AC-input power supply LEDs and their meanings.
    1300 W Power Supply AC Power Cords
    Ta b l e A - 6 lists the specifications for the AC power cords that are available for the 1300 W AC-input 
    power supply. The table includes a power plug illustration for each power cord.
    NoteAll 1300 W power supply power cords have an IEC60320/C19 appliance plug at one end. Power supply output 
    •84.7 A @ 12 V @ (data)
    •12.5 A @ 3.3 V (data)
    •16.7 A @ –50 V (PoE)
    Output holdup time 20 ms minimum 
    Maximum kVA rating 1.76 kVA
    Max heat dissipation 1568 BTUs/hr
    Minimum software 
    requirementCisco IOS Release 12.1(12c)EW
    Power over Ethernet (PoE) Supported, up to 800 W (211 Cisco phones in combined mode)
    Table A-4 1300 W AC-Input Power Supply Specifications (continued)
    Item Specification
    Table A-5 1300 W AC-Input Power Supply LEDs
    LED Meaning
    INPUT OK
    •Green—Source AC voltage is OK. (Input voltage is 85 VAC or 
    greater.)
    •Off—Source AC voltage falls below 70 VAC, is not present, or the 
    power supply is turned off.
    FAN OK
    •Green—Power supply fan is operating properly.
    •Off—Power supply fan failure is detected.
    OUTPUT FAIL
    •Red—Problem with one or more of the DC-output voltages of the 
    power supply is detected.
    •Off—DC-output voltage with acceptable margins.
    NoteFor proper operation of the OUTPUT FAIL LED, systems with 
    single power supplies must be configured with a minimum of 
    one fan tray assembly and one supervisor engine. Systems with 
    dual power supplies must have a minimum configuration of one 
    fan tray assembly, one supervisor engine, and one additional 
    module. Failure to meet these minimum configuration 
    requirements can cause a false power supply output fail signal. 
    						
    							A-9
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Appendix A      Power Supply Specifications
      1300 W AC-Input Power Supply
    Table A-6 1300 W AC-Input Power Supply Power Cords
    LocalePower Cord Part 
    Number Length Cordset RatingAC Source Plug 
    Ty p e
    Japan, North 
    America CAB-US520-C19-US= 
    (was CAB-7513AC=)14 ft (4.3 m) 20 A, 125 VAC NEMA 5-20
    Australia, 
    New ZealandCAB-A3112-C19-AUS= 
    (was CAB-7513ACA=)14 ft (4.3 m) 15 A, 250 VAC SAA/3,
    AS/NZZS 3112-1993
    Europe (except 
    Italy)CAB-CEE77-C19-EU= 
    (was CAB-7513ACE=)14 ft (4.3 m) 16 A, 250 VAC CEE 7/7
    Italy CAB-C2316-C19-IT= 
    (was CAB-7513ACI=)14 ft (4.3 m) 16 A, 250 VAC 1/3/16, CEI 23-16
    United 
    KingdomCAB-BS1363-C19-UK= 
    (was CAB-7513ACU=)14 ft (4.3 m) 13 A, 250 VAC BS 89/13
    BS 1363/A
    Argentina CAB-IR2073-C19-AR= 
    (was CAB-7513ACR=)14 ft (4.3 m) 16 A, 250 VAC IRAM 2073
    Japan, North 
    America 
    (locking)
    200–240 VAC 
    operationCAB-AC-2800W-TWLK= 13.6 ft 
    (4.1 m)16 A, 250 VAC NEMA L6-20
    120362
    120356
    120357
    120358
    120359
    120356
    120361 
    						
    							A-10
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Appendix A      Power Supply Specifications
      1400 W AC-Input Power Supply
    1400 W AC-Input Power Supply
    The 1400 W AC-input power supply (PWR-C45-1400AC), shown in Figure A-3, is supported in the 
    following Catalyst 4500 E-series switches:
    •Catalyst 4503-E
    •Catalyst 4506-E
    •Catalyst 4507R-E
    •Catalyst 4507R+E
    •Catalyst 4510R-E
    •Catalyst 4510R+E Japan, North 
    America 
    (nonlocking)
    200–240 VAC 
    operationCAB-AC-2800W-6-20= 13.2 ft 
    (4.0 m)16 A, 250 VAC NEMA 6-20 
    non-locking 
    Europe CAB-AC-2800W-EU= 13.2 ft 
    (4.0 m)16 A, 250 VAC CEE 7/7
    South Africa, 
    IndiaCAB-BS546-C15-SA= 
    (was CAB-7513ACSA)13.6 ft 
    (4.1 m)16 A, 250 VAC BS 456 
    International CAB-AC-2800W-INT= 13.6 ft 
    (4.1 m)16 A, 250 VAC IEC 309
    Israeli CAB-S132-C19-ISRL 14 ft (4.3 m) 16 A, 250 VAC SI32
    UPS 220V CAB-C19-CBN 9 ft (2.74 m) 20 A, 250 VAC IEC-60320-C20
    Table A-6 1300 W AC-Input Power Supply Power Cords (continued)
    LocalePower Cord Part 
    Number Length Cordset RatingAC Source Plug 
    Ty p e
    120355
    120357
    203795
    120360
    130922
    130923 
    						
    							A-11
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Appendix A      Power Supply Specifications
      1400 W AC-Input Power Supply
    Figure A-3 1400 W AC-Input Power Supply Features
    1400 W AC-Input Power Supply Specifications
    Ta b l e A - 7 lists the specifications for the 1400 W AC-input power supply. 1AC-input receptacle3Captive installation screws
    2Power on/off switch
    2313751
    2
    3
    Table A-7 1400 W AC-Input Power Supply Specifications
    Item Specification
    AC-input type Autoranging input with power factor corrector
    NotePower factor correction is a standard feature on all Catalyst 4500 
    E-series AC-input power supplies. PFC reduces the reactive 
    component in the source AC current allowing higher power 
    factors (typically 99 percent or better) and lower harmonic 
    current components.
    AC-input voltage
    •Low-line (120 VAC nominal)—85 VAC (min) to 132 VAC (max)
    •High-line (230 VAC nominal)—170 VAC (min) to 264 VAC (max)
    AC-input current
    •16 A @ 120 VAC 
    •7 A @ 240 VAC
    AC-input frequency 50/60 Hz (nominal) (±3 Hz for full range) 
    						
    							A-12
    Catalyst 4500 E-Series Switches Installation Guide
    OL-13972-02
    Appendix A      Power Supply Specifications
      1400 W AC-Input Power Supply
    Ta b l e A - 8 list the 1400 W AC-input power supply LEDs and their meanings. Branch circuit requirement Each chassis power supply should have its own dedicated, fused-branch 
    circuit: 
    •For North America—15 A or 20 A
    •For International—Circuits sized to local and national codes
    •All Catalyst 4500 E-series AC-input power supplies require 
    single-phase source AC.
    •All AC power supply inputs are fully isolated.
    –Source AC can be out of phase between multiple power supplies 
    in the same chassis, which means that PS1 can be operating 
    from phase A and PS2 can be operating from phase B.
    –For high-line operation, the power supply operates with the hot 
    conductor wired to a source AC phase and the neutral conductor 
    wired either to ground or to another source AC phase as long as 
    the net input voltage is in the range of 170 to 264 VAC.
    –Source AC can be out of phase between AC inputs on power 
    supplies that are equipped with multiple AC inputs, which 
    means that power cord 1 can be plugged into phase A and 
    power cord 2 can be plugged into phase B.
    Power supply output  2473 W maximum 
    1360 W + 40 W redundant mode (data)
    Power supply output (AC 
    supply)113.4 A @ +12 V 
    12.2 A @ +3.3 V (data)
    Output holdup time 20 ms minimum 
    Max heat dissipation 1048 BTUs/hr
    Maximum kVA rating 1.76 kVA
    Minimum software 
    requirementCisco IOS Release 12.2(18)EW
    Power over Ethernet Not supported
    1
    1. A Catalyst 4503-E with a Catalyst 4500 E-series Supervisor Engine II-Plus TS and a 1400W AC power supply provides 158.4 
    W of PoE to ports on the supervisor engine. Switching modules in other slots will not be able to provide PoE.
    Table A-7 1400 W AC-Input Power Supply Specifications (continued)
    Item Specification 
    						
    All Cisco manuals Comments (0)