    							Section 6: Specifications
    Roadie HD+35K User Manual6-5020-100340-02 Rev. 1  (01-2010)
    6.4.6  GPIO Input
    6.4.7 Control Port (From Ballast)
    6.4.8 Ballast Ports
    6.5 Power
    6.5.1 Projection head
    Number of I/O lines 7, each assignable as input or output
    Connector type 9-pin subminiature D (male)
    Type of connection Dry contact
    Output sink current 
    (logic low)100 mA @ 1V
    Maximum power output +12VDC @ 200 mA
     
    NOTE:  Shared with 9-pin RS422 port.
    Number of connectors 1
    Interface RS232
    Connector type 9-pin subminiature D (male)
    Number of connectors 1
    Interface +5V TTL-compatible
    NOTE:  Opto-isolated at ballast end.
    Connector type 9-pin subminiature D (female)
    Number and type of outputs 1 – lamp enable (low = enable lamp)
    4 – safety interlocks (high = disable lamp)
    1 – +5VDC for opto-isolated interface
    Projection Compartment AC (near Panel B, at front)
    Connector type & rating (1) IEC 320-compatible, 10 A rating
    Voltage range, nominal 200 – 240 VAC ±10% 
    Line frequency, nominal 50 – 60 Hz
    AC input rating 10 A
    Max. inrush current 
     35 A
    Max. current consumption 
     3 A
    Max. power consumption 
     700 W 
    						
    							6-6Roadie HD+35K User Manual020-100340-02 Rev. 1   (01-2010)
    Section 6: Specifications
    6.5.2 7 kW 3-Phase Ballast (38-814001-51)
    6.6 Lamps
    Replace before times:
    NOTES: 1) Current range shown includes “over-drive”, which is 10% more than the original lamp rating. 
    2) Optimized brightness requires CDXL lamp.
    Lamp (DC)
    Max. operating voltage 46 VDC 
    Max. start-up voltage 155 VDC
    Max. current consumption 180 A
    Max. power consumption 6600 W
    Connector type Female CAM Lock receptacle (+red)
    Male CAM Lock receptacle (–black)
    Input Ratings 200-230 V 3~ +PE, 24 A, 50-60 Hz/380-415V 3~ +N +PE, 
    16 A, 50-60 Hz
    Inrush current (max.) 
    note: excluding lamp
    						
    							Section 6: Specifications
    Roadie HD+35K User Manual6-7020-100340-02 Rev. 1  (01-2010)
    6.7 Reflectors
    10,000 hours
    6.8 Audible Noise
    67.2 dBA maximum 
    6.9 Safety
    • CAN/CSA C22.2  No. 60950-1-07,  2nd Edition 
    • UL 60950-1, 2
    nd Edition 
    • IEC 60950-1, 2
    nd Edition (2005)
    6.10 EMC Emissions
    • FCC CFR47, Part 15, Subpart B, Class A – Unintentional Radiators
    • CISPR 22: EN55022: Class A – Radio disturbance characteristics for Information Technology Equipment 
    (ITE)
    6.11 EMC Immunity
    • CISPR 24/ EN55024: All parts for immunity characteristics for Information Technology Equipment (ITE)
    6.12 Operating Environment 
    6.12.1 Non-Operating Environment
    Temperature 10°C to 35°C (50°F to 95°F)
    Humidity (non-condensing) 20% to 80%
    Altitude 0 – 3000 meters
    Tilt, any angle 15° max.
    Temperature -25C to 65°C (-13°F to 149°F)
    Humidity (non-condensing) 0% to 95%  
    						
    							6-8Roadie HD+35K User Manual020-100340-02 Rev. 1   (01-2010)
    Section 6: Specifications
    6.12.2 Weight & Size
    NOTES: 1) Only applies to the product dimensions, but not to the product weight (since the installed weight of the 
    product includes the heaviest lens, and all accessories). 
    2) Excludes lens and cabling. 3) All weights and 
    dimensions subject-to-change.
    Standard Dimensions (Refer to Section 6: Specifications)
    Shipping Weights
    Installed Weight
     Figure 6-1 Overall Size Dimension Product dimensions (W x L x H) without lens 
    (including feet at minimum height position) 
    and without handles1257 mm x 684 mm x 577 mm
    49.5” x 26.5” x 22.7”
    Product dimensions (W x L x H) without lens 
    (including feet at minimum height position) 
    and handles1362 mm x 800 mm x 577 mm
    53.6” x 31.5” x 22.7”
    Packaging dimensions (W x L x H) , shipped 
    without lens attached1650 mm x 1040 mm x 890 mm
    65” x 41” x 35”
    Projection Head 535 lb (242.7 kg)
    Ballast 145 lb (66 kg)
    FredFrame™ 166 lb (76 kg)
    Projection Head 460 lb (209.1 kg)
    Ballast 110 lb (50 kg)
    FredFrame™ 110 lb (50 kg) 
    						
    							Section 6: Specifications
    Roadie HD+35K User Manual6-9020-100340-02 Rev. 1  (01-2010)
    6.13 Standard and Optional Components
    6.13.1 Standard (Sold with Product)
    6.13.2 Optional 
    (Sold Separately)
    Projection head with built-in keypad and standard IR remote (configured for IR operation, batteries included)
    25 ft cable for conversion of standard IR remote to wired operation
    Line Cord, 10-foot, 15 amp, North American 220V
    Face shield (required for lamp handling)
    Dual SD/HD-SDI input module (38-804656-xx)
    Roadie HD+35K User Manual
    Misc. hardware, including Allen Keys
    Projection Lenses
    The projection head is compatible with the following optional lenses:
    0.8:1 fixed throw ratio lens 113-104106-XX
    1:1 fixed throw ratio lens  38-809071-XX
    1.25 – 1.45:1  38-809073-XX
    1.45 – 1.8:1  38-809074-XX
    1.8 – 2.4:1  38-809075-XX
    2.2 – 3.0:1  38-809076-XX
    3.0 – 4.3:1  38-809077-XX
    4.3 – 6.0 :1  38-809072-XX
    5.5 – 8.5 :1  38-809078-XX
    Motorized Auxillary Lens Mount   38-813019-XX
    1.26x Anamorphic Lens   38-809054-XX
    Lamp Ballasts
    Remote Lamp ballast (7 kW)    38-814001-XX
    Ballast (Remote) Cable Kits
    2 meters (6½ ft.)   38-814003-XX
    7.5 meters (25 ft.)   38-814004-XX
    15 meters (50 ft.)   38-814005-XX
    30 meters (100 ft.)   38-814006-XX 
    						
    							6-10Roadie HD+35K User Manual020-100340-02 Rev. 1   (01-2010)
    Section 6: Specifications
    Other
    Remote IR Sensor - communication cables  Ethernet, RS-232, and RS-422
    Compact/Lite remote 03-900566-XX
    Christie  TWIST Module for arbitrary image warping and edge blending  108-103001-XX
    FredFrame™ Rigging Frame   38-814007-XX
    Rigging Clamps for flying projection head by handles  113-102101-XX
    10-Bit KoRE Librarian Setup Software Website download (password 
    required)
    High-contrast internal aperture kit  38-813028-XX
    Analog and Digital Input Modules   Refer to  Section Appendix D: 
    Optional Input Modules
    Xenon Lamp  2 kW, 3 kW,  4.5 kW, and 6 kW
    Service Manual 020-100341-XX 
    						
    							Roadie HD+35K User ManualA-1020-100340-02 Rev. 1 (01-2010)
    Appendix A:  Serial Communication Cables
    A.1 Serial Links to Projector
    A.1.1General Communications
    A serial link of RS-232 or RS-422 enables ASCII communication with the projector so that it can be controlled 
    remotely from a PC or other controller. From a PC, connect a standard 9-wire RS-232 serial cable to the RS232 IN port 
    located on the side of the projection head. Or, for long-distance (>100 ft.) links with an RS-422-compatible PC or 
    controller, connect RS-422 cable to an RS422 port located on the side or rear panel of the projection head.
    A.1.2Software Downloads
    Downloading new software to the projector requires RS-232 or RS-422 connected to the 9-pin connectors on the side 
    of the projector only—do not download using either of the 6-pin XLR RS-422 ports located at the rear of the projector.
    NOTE:Using a rear RS-422 port (6-pin XLR) or Ethernet link for downloading new software to 
    the projector is not supported.
    A.1.3 RS-422 Connections
    Depending on your RS-422-compatible device or RS-232 – RS-444 converter, the cabling wiring can vary, and may 
    require a custom cable. There is no single standard pinout for RS-422.
    Shielded Multi-conductor Cable
    MALE FEMALE 
    From projector to computer (RS-232)
    Standard RS-232 cable, with 9-Pin D-connectors
    Projector
    RS-232 IN
    (female)Computer
    (male)
    For computers having a 9-pin AT type serial port
    ShieldShield
    22
    5
    4
    3
    2
    13 5
    3
    5GNDGND
    TxRx
    RxTx
    PROJ 1 
    						
    							A-2Roadie HD+35K User Manual020-100340-02 Rev. 1 (01-2010)
    Appendix A: Serial Communication Cables
    Shielded Multi-conductor Cable
    MALE 
    2 1
    3
    4
    56
    8 7
    9
    Projector
    RS-422 IN
    (female)
    Wiring
    From projector (side) to RS-422 compatible computer
    • Wiring from your controller (or RS-232-to-RS-422
    adapter) may vary. Consult the documentation
    for your device.
    • Connect Tx+  to Rx+
    • Connect Tx- to Rx-
    • Connect Rx+  to Tx+
    • Connect Rx- to Tx-
    1  TXD+
    2  RXD+
    3  TXD-
    4  RXD-
    5  n/c6  +12V
    7  n/c
    8  GND
    9  n/c
    PROJ 1
    From projector (rear) to RS-422 compatible computer
    Wiring
    Shielded Multi-conductor Cable
    FEMALE 
    Projector
    RS-422
    (male)
    Rx+
    +12V
    GNDTx+
    Rx – Tx –
    1
    2
    345 6
    1
    2
    3
    4
    5
    6
    Male proj. port 1
    • 
    • Wiring varies among computers. Consult
    the documentation for your device.
    Generally, the +12V (pin 5) is not connected. 
    Consult the documentation for your device.
    • Connect Tx+  to Rx+
    • Connect Tx- to Rx-
    • Connect Rx+  to Tx+
    • Connect Rx- to Tx-
    Not for software downloads.IMPORTANT
    PROJ 1 
    						
    							Appendix A: Serial Communication Cables
    Roadie HD+35K User ManualA-3020-100340-02 Rev. 1 (01-2010)
    Shielded Multi-conductor Cable
    MALE FEMALE 
    From projector to projector via RS-232
    Standard RS-232 cable,with 9-Pin D Connectors
    Projector
    RS-232 OUT
    (male)Projector
    RS-232 IN
    (female)
    ShieldShield
    22
    5
    4
    3
    2
    13 5
    3
    5GNDGND
    Tx
    Rx
    Rx
    Tx
    PROJ 2PROJ 1
    Shielded Multi-conductor RS-422 Cablewith 6-pin XLR Connectors
    From projector to projector via RS-422
    Projector
    RS-422
    (male)Projector
    RS-422
    (male)
    MALE FEMALE 
    Shield Shield
    toanothercable
    Wiring: Extension cable
    Rx+
    +12 V
    GNDTx+
    Rx – Tx –
    Rx+
    +12 VGNDTx+
    Rx – Tx –1
    2
    3
    4
    5
    6 1
    2
    3
    4
    5
    6
    FEMALE FEMALE 
    Shield Shield
    Wiring: “Swap” cable
    Rx+
    +1 2 V
    GNDTx+
    Rx – Tx –
    Rx+
    +12 VGNDTx+
    Rx – Tx –1
    2
    3
    4
    5
    6 1
    2
    3
    4
    5
    6NOT CONNECTED
    Do not connect +12V at pin 5, or
    damage to equipment may result!WARNINGLUG
    LUG
    LUG
    LUG
    PROJ 1PROJ 2
    RS-422 
    						
    							A-4Roadie HD+35K User Manual020-100340-02 Rev. 1 (01-2010)
    Appendix A: Serial Communication Cables
    Shielded Multi-conductor Cable
    MALE FEMALE 
    From projector to projector via RS-232
    Standard RS-232 cable,with 9-Pin D Connectors
    Projector
    RS-232 OUT
    (male)Projector
    RS-232 IN
    (female)
    ShieldShield
    22
    5
    4
    3
    2
    135
    3
    5GNDGND
    Tx
    Rx
    Rx
    Tx
    PROJ 2PROJ 1 
    						