Page 151
Appendix C: DMX / ArtNet Mirage M Series User ManualC-3020-100575-02 Rev. 1 (11-2010) Mirage M Series Setup Personality Channel Group Name DescriptionDefault Value Notes 1 Safety Slider Lock0-171 Locked 172-255 Unlocked255No Channel changes will be applied when this control is locked. Channel changes made while the slider is locked will be applied once the slider becomes unlocked. 2VideoFade to/from Black0-85 Black screen (Picture mute ON) 172-255 Live Video (Picture mute OFF)255If you wish to...
Page 152
C-4Mirage M Series User Manual020-100575-02 Rev. 1 (11-2010) Appendix C: DMX / ArtNet Channel Group Name DescriptionDefault Value Notes 14 Input InputInput Selection 0 to 9 Slot 1, Input 1 10 to 19 Slot 1, Input 2 .... 50 to 59 Slot 1, Input 6 60 to 69 Slot 2, Input 1 .... 110 to 119 Slot 2, Input 6 120 to 129 Slot 3, Input 1 .... 170 to 179 Slot 3, Input 6 180 to 189 Slot 4, Input 1 .... 230 to 239 Slot 4, Input 6255 Will not change input on default 15 Image Image Freeze0-85 Unfreeze image 172-255...
Page 153
Appendix C: DMX / ArtNet Mirage M Series User ManualC-5020-100575-02 Rev. 1 (11-2010) Channel Group Name DescriptionDefault Value Notes 24Setup FunctionsTest Pattern0-19 Off 20-39 Grid 40-59 Grey Scale 16 60-79 White 80-99 Flat Grey 100-119 Black 120-139 Checker 140-159 13 Point 160-179 Color Bars 180-199 Aspect Ratio 200-219 Edge Blend 220-239 Boresight0 25 Colormetry Brightness0 to 255 Scaled as % of total control range, which is 0 to 100128 26 Colormetry Contrast0 to 255 Scaled as % of total control...
Page 154
C-6Mirage M Series User Manual020-100575-02 Rev. 1 (11-2010) Appendix C: DMX / ArtNet Channel Group Name DescriptionDefault Value Notes 34 Real Time EventsRTE 10-85 Cancel current running RTE 172-255 Triggers RTE 1128 35Real Time EventsRTE 20-85 Cancel current running RTE 172-255 Triggers RTE 2128 36 Real Time EventsRTE 30-85 Cancel current running RTE 172-255 Triggers RTE 3128 37 ReservedReserved for future expansion No reset 38 ReservedReserved for future expansion No reset Mirage M Series Show...
Page 155
Appendix C: DMX / ArtNet Mirage M Series User ManualC-7020-100575-02 Rev. 1 (11-2010) Channel Group Name DescriptionDefault Value Notes 13 InputChannelProjector Channel Selection 0 to 9 Projector Channel 1 10 to 19 Projector Channel 2 20 to 29 Projector Channel 3 .... 180 to 189 Projector Channel 19 190 to 199 Projector Channel 20255 14 InputInputInput Selection 0 to 9 Slot 1, Input 1 10 to 19 Slot 1, Input 2 .... 50 to 59 Slot 1, Input 6 60 to 69 Slot 2, Input 1 .... 110 to 119 Slot 2, Input 6 120 to...
Page 156
C-8Mirage M Series User Manual020-100575-02 Rev. 1 (11-2010) Appendix C: DMX / ArtNet Channel Group Name DescriptionDefault Value Notes 3 LensLens shift enable0-85 Lens shift disable 172-255 Lens shift enable255 Locks all lens motors 4 LensZoom (Coarse) 0 to 255 Scaled as % of total control range, which is 0 to 2100128 Locked by channel “Lens shift enable”. 5 LensZoom (Fine) 0 6 LensFocus (Coarse) 0 to 255 Scaled as % of total control range, which is 0 to 2100128 Locked by channel “Lens shift...
Page 157
Appendix C: DMX / ArtNet Mirage M Series User ManualC-9020-100575-02 Rev. 1 (11-2010) Channel Group Name DescriptionDefault Value Notes 15 MacroFunctionProjector Orientation 0-9 Front Projection 10-19 Rear Projection 20-29 Front Projection Inverted 30-39 Rear Projection Inverted On Screen Display 40-59 OSD On 50-59 OSD Off 60-69 Lens Calibrate 86 LOAD Test Pattern 100-104 Off 105-109 Grid 110-114 Grey Scale 16 115-119 White 120-124 Flat Grey 125-129 Black 130-134 Checker 135-139 13 Point 140-144 Color...
Page 158
C-10Mirage M Series User Manual020-100575-02 Rev. 1 (11-2010) Appendix C: DMX / ArtNet Channel Group Name DescriptionDefault Value Notes 16Lamp/ PowerLamp/Power functionsLamp Power Scaled as % of total control range,. Examples are given for 350W and 200W lamps: 00 0% 300 Watt / 150 Watt .... 10 310 Watt / 157 Watt .... 20 320 Watt / 164 Watt .... 30 330 Watt / 171 Watt .... 40 340 Watt / 178 Watt .... 50 350...
Page 159
Appendix C: DMX / ArtNet Mirage M Series User ManualC-11020-100575-02 Rev. 1 (11-2010) Channel Group Name DescriptionDefault Value Notes 20 ColormetryVideo Signal/ Color space, Output ColorColor Space 0-9 RGB 10-19 YCbCr SDTV (ITU-R BT.601) 20-29 YCbCr HDTV (ITU-R BT.709) 86 LOAD Output Color 90-99 Max Drives 100-109 Color Temperature (enables 21) 110-119 SD Video 120-129 HD Video 130-139 User setting 1 140-149 User setting 2 150-159 User setting 3 160-169 User setting 4 171 EXECUTE255 21...