Home > Christie > Projector > Christie Projector CP2230 User Manual

Christie Projector CP2230 User Manual

Here you can view all the pages of manual Christie Projector CP2230 User Manual. The Christie manuals for Projector are available online for free. You can easily download all the documents as PDF.

Page 151

Appendix B: Serial API
CP2230 User ManualB-5020-100430-07 Rev. 1 (05-2014)
BLUVSet or query the blue vertical EDC value. 
RSET Set all six EDC values to their default value.
EXAMPLES:
(EDC?) Get all six EDC values
(EDC 0 3 1 2 2 3) Set all six EDC values at once. Set red horizontal to 0,  green horizontal to 3, blue horizontal to 1, red vertical 
to 2, green vertical to  2 and blue vertical to 3.
(EDC+REDH?) Set the re d horizontal EDC value
(EDC+REDH 2) Set the red horizontal EDC value to 2
(EDC+BLUV?)...

Page 152

B-6CP2230 User Manual020-100430-07 Rev. 1 (05-2014)
Appendix B: Serial API
RNGPMotor moving range in posit ive direction. Read-only.
RSET Move motor to the center flag then move back to current position. Only valid parameter for this command 
is 1. SET only command.
STRT Start motor moving in specified dire ction, where direction can be (-1, 1). Write-only for v1.3 or newer.
STOP Stops the motor. Write-only for v1.3 or newer.
MOVR Moves the motor a given number of steps based on th e current location....

Page 153

Appendix B: Serial API
CP2230 User ManualB-7020-100430-07 Rev. 1 (05-2014)
Lamp History (HIS)
Retrieve the history of installed lamp entries, including the current lamp. There is an individual entry for each lamp 
in the history. The format for  each entry is: (HIS!AAA “BBBB/BB/BB”  “C” “D” EEE FFF GGG HHH III JJJ 
KKK).
A = Lamp Number
B = Date Installed
C = Serial Number 
D = Type
E = Strikes
F = Failed Strikes
G = Failed Restrikes
H = Unexpected Lamp Off
I = Pre-installed Hours (will always re turn...

Page 154

B-8CP2230 User Manual020-100430-07 Rev. 1 (05-2014)
Appendix B: Serial API
FCOPNot supported.
FREN Not supported.
EXAMPLES:
(ICP+FSET “ones4K_LE.LUT -SCC”) Copies the “ones4K_LE.L UT-SCC” PCT file from the TPC’s ftproot directory to the 
LUT-SCC directory on the ICP.
(ICP+FSET “Nominal.MCGD”) Copy the “Nominal.MCGD” MC GD file from ftproot to the MCGD directory on the ICP.
(ICP+FDEL “Nominal.MCGD”) Deletes the “Nominal.MCGD” file from the ICP. 
ILS File (ILF)
Set or get the current ILS file fo r the...

Page 155

Appendix B: Serial API
CP2230 User ManualB-9020-100430-07 Rev. 1 (05-2014)
RSETMove motor to center flag and then move back to  current position. Only valid parameter for this command 
is 5. SET only command.
RSTS Motor reset status (0-100%)
EXAMPLES:
(ILS 1) Enable ILS, lens  will be moved to the position in each channel
(ILS 0) Disable ILS, position da ta in each channel will not be used. Moving lens will no t affect any channel setting 
(ILS+CALB 5) Calibrate all axes  of the lens. Set only command...

Page 156

B-10CP2230 User Manual020-100430-07 Rev. 1 (05-2014)
Appendix B: Serial API
STUPAdd test pattern from full list of defi ned test patterns to the user list
USER Select test pattern from user  defined test pattern list
EXAMPLES:
(ITP ?) Get current test  pattern, 0 means no test pattern is used.
(ITP 4) or (ITP “ “) Use number  or string to set test pattern
(ITP+USER 4) or (ITP+USER “ “) Use number or string  to set test pattern from user’s test pattern list.
(ITP+FULL 1) Use full screen size
(ITP+FULL 0)...

Page 157

Appendix B: Serial API
CP2230 User ManualB-11020-100430-07 Rev. 1 (05-2014)
Link Decrypter Bypass (LDB)
Setting LD bypass to TRUE (1) will bypass the link decrypter (LD). Only use if marriage is broken and content being played is 
not CineLink 2 encrypted  (non D-Cinema content).
SUBCODEDESCRIPTION OF USE
Cxxx Replace xxx with the channel num ber. Valid range is 101 - 164.
NONE Set to 1 to bypass and 0 to not bypass.
EXAMPLES:
(LDB+C108 1) Bypass link decrypter on channel 108.
(LCT 0) Use link decr ypter...

Page 158

B-12CP2230 User Manual020-100430-07 Rev. 1 (05-2014)
Appendix B: Serial API
Lens Horizontal Position Adjustment (LHO)
Adjust lens offset to specific horizontal position with a specified direction. NOTE: This command can only be 
used to update the current ILS file . Changing the horizontal offset for the current channel will change the horizon-
tal offset for any channel using the same ILS file.
Use command wi thout subcode:
• If ILS is ON, motor will move to specified  steps and save data to the active...

Page 159

Appendix B: Serial API
CP2230 User ManualB-13020-100430-07 Rev. 1 (05-2014)
LampLOC™ Module (LLM)
Allows adjustment of lamp position to optimize intensity and uniformity of the optical system. This is referred to 
as the LampLOC™ feature and can be done automatically or manually.
SUBCODEDESCRIPTION OF USE
AUTO Set to 1 to do LampLOC™ automatically. It will do calibration first, then move the X, Y, Z-motors to find 
the maximum brightness. Set to 0 to cancel auto adjustment and restore the previous...

Page 160

B-14CP2230 User Manual020-100430-07 Rev. 1 (05-2014)
Appendix B: Serial API
Lamp Changed (LPC)
Record current lamp information into the lamp history, then start a new entry. Set lamp information of a new lamp 
type ID, serial number, and pre-used hours. When the values are set, use the (LPC 1) command to add the record.
SUBCODEDESCRIPTION OF USE
LPID Set lamp type ID for the new lamp
NONE Save lamp information to lamp history
PREV Set lamp previous lamp hours for the new lamp
SERL Set lamp serial number...