Page 31
— 29 — No Device to be checked Operation Note Page 1 Batch test 1 2 Test Device : RAM, FLASH, Display, 32 Print, Time, Drawer 2 Batch test 2 3 Test Device : Display, Back light 32 3 RAM WRITE/READ test n011 33 4 RAM READ only test n111 33 5 FLASH Check SUM test n512 34 6 FLASH CLEAR/WRITE/READ test n612 34 7 CF-CARD WRITE/READ test pn013 35 8 CF-CARD READ only test pn113 35 9 CF-CARD CLEAR test pn213 36 10 CF-CARD...
Page 32
— 30 — 7-6. Operation of each test [ 1 ] Batch test 1 [Function] RAM test, FLASH test, display test, test print, time setting and drawer open test are performed continuously. Make sure to connect the printer to COM1. [Operation] Refer to the page for the details of the following tests. Operation : 2 ST The following tests are performed automatically. (1) RAM test : WRITE/READ all block test (2) FLASH : Check SUM test (3) Test print (4) Times setting : Set the following...
Page 33
— 31 — [ 3 ] RAM WRITE/READ test [Function] WRITE/READ test for RAM is performed. A counter is displayed for RAM test as follows. [Operation] Operation : n 0 1 1 ST n: 01 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) [LCD] RAM n011 RAM WR OK END n011 [PRINT] NOTE: Prints the address of the error in case the test ended with an error. Prints the address of the error in case the test ended with an error. RAM n011 RAM...
Page 34
— 32 — [ 5 ] FLASH Check SUM test [Function] This test will check SUM test for FLASH is performed. [Operation] Operation : n 5 1 2 ST n: 01 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) [LCD] [PRINT] FLASH 512 FLASH CHK SUM OK END 512 FLASH 512 FLASH CHK SUM OK END 512 [ 6 ] FLASH CLEAR WRITE/READ test [Function] The CLEAR & WRITE/READ test for FLASH is performed. After deleting the memory by CLEAR, WRITE/READ test is...
Page 35
— 33 — [ 7 ] CF-CARD WRITE/READ test [Function] This test will check the write/read test (connection test) for CF-CARD. Perform the CF-CARD clear test, before start of this test. Note that this test does not ensure the data inside the CF-CARD as well as its performance. [Operation] Operation : p n 0 1 3 ST p : designates PCMCIA SLOT 0 = CF 1 = PCMCIA n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) [LCD] NG and the...
Page 36
— 34 — [ 9 ] CF-CARD CLEAR test [Function] This test will check the clear test for CF-CARD. Note that this test does not ensure the data inside the CF-CARD as well as its performance. [Operation] Operation : p n 2 1 3 ST p: designates PCMCIA SLOT 0 = CF 1 = PCMCIA n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) [LCD] NG and the address are displayed if CLEAR cannot be done normally. NG and the address are printed if...
Page 37
— 35 — [ 11 ] LCD test [Function] This test will check the LCD display. In case of one time check only, the test can be ended by the judgment (OK or NG) of the opera- tor. The display can be switched by the touch of the panel. The display will not change to the next one unless the panel is touched. [Operation] Press [OK] key or [NG] key to end the test when performing one time check. "OK" = 1, "NG" = 9 Operation : n 0 2 1 ST n: 0 = One time check (can...
Page 38
— 36 — [ 13 ] LCD Backlight OFF test [Function] This is a test for the LCD backlight. The test ends upon judgment of the operator between [OK] and [NG]. [Operation] Press [OK] key or [NG] key to end the test when performing one time check. "OK" = 1, "NG" = 9 Operation : 1 2 1 ST [LCD] [PRINT] BACK LIGHT 121 BACK LIGHT OK END 121 BACK LIGHT 121 BACK LIGHT OK END 121 [ 12 ] LCD calibration test [Function] This will test the calibration of the LCD (touch panel)....
Page 39
— 37 — [ 14 ] Remote Cust DISP test [Function] This test will check whether REMOTE DISP can be displayed. Make sure to connect REMOTE DISP to COM3. In case of one time check only, the test can be ended by the judgment (OK or NG) of the opera- tor. Pastel green (white plus green) appears as the backlight, which turns off upon the end of the test. * When changing the baud rate, make sure to change the REMOTE DISP setting. [Operation] Press [OK] key or [NG] key to end the test...
Page 40
— 38 — [ 15 ] External printer print test [Function] This test will check the print test for the RS232C I/F printer. Connect the printer to the COM which is to be tested. [Operation] Operation : x1 x2 x3 n 0 3 d ST X1: Print test pattern (0 = A pattern, 1 = B pattern) X2: Port selection (1 = COM1, 2 = COM2, 3 = COM3) X3: Baud rate selection (1 = 4800 bps, 2 = 9600 bps, 3 = 19.2 kbps) n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC"...