Page 71
— 69 — ActionMeaningPrompt message E140 Wrong menu. E141 Press twice before finalization. E145 Arrangement syntax er- ror. E150 Incorrect value entry. E151 Incorrect Key Pressed. E152 PGM File or Memory number does not Exist. E164 Employee No. is not Found in the Employee File. E165 Employee No. is not Clocking-in. E166 Employee No. is Occu- pied. E167 Incorrect Job code. E168 Your Operation is out of Schedule. Please Call Manager. E169 Work Hours Exceeded. Please Call Manager....
Page 72
— 70 — ActionMeaningPrompt message E200 Insert CF Card. E201 Format error. E203 Insufficient memory. E205 The file already exists. Do you replace? YES:Replace the file. NO :Input new name. E240 Customer No. is occu- pied. E241 Customer memory full. E242 Customer not found. E243 Illegal Site ID. E244 Credit limit over. E251 Magnetic card error. E252 Enter customer name. E253 Enter address. E254 Enter phone number. CF card is not inserted to the slot. CF card data or formats illegal....
Page 73
— 71 — Data cannot be printed out. Backup to R/J printer? Do you want to clear data? Cancel OK? Please wait. Item Consolidation Mode Non Consolidation Mode REG Mode REFUND Mode REG- Mode Training REG2 Mode Please Sign on. Enter Check/Table Number. Enter Table Number. Enter Number of covers. Enter Seat Number. Perform Slip Printing. Issue Guest Receipt. Perform Validation Printing. Perform Check Printing. Perform Check Endorsement. Operation Code? Re_configuration... Re_configuration end Clock-in OK?...
Page 74
— 72 — 9-3 System error code All error codes are contained in the list below. These error codes are displayed or printed on error log report. Error code Meaning 0010 Handler access error (software) 0011 Cannot execute handler (system configuration) 0012 Break by PC 0013 Break by ECR 0014 DSR off before receiving command packet 0015 Receive illegal command number of command packet 0016 Receive illegal character 0017 Send error (hardware) 0018 Receive error (hardware) 0019...
Page 75
— 73 — 0079 Z lock release error on satellite terminal 0081 Check tracking master is removed from system. 0082 Check tracking backup master is removed from system. 0128 Parameter error / Maximum length of send error 0130 Error drive 0134 Network parameter error 0138 Detect error in core system 0140 Parameter error (record length exceeds work buffer) 0141 EOF over 0144 Calculation overflow 0145 Undefined value of n_open () mode 0146 Mismatch of type when closing network...
Page 76
— 74 — 9-4. OS Fatal Error When a fatal error occurs during an operation of the operating system, normal operation becomes im- possible afterwards. Therefore, the OS displays a message as shown below and stops the operation of ECR. Such errors include errors of the OS (ITRON) itself, driver system errors, etc. The values of Error No. and Error Code vary according to errors. * These are intentional system halting errors to prevent a system runaway due to software. Types of errors may be increased in...
Page 77
— 75 — Description of Errors (1) Semaphore acquisition error Error No. -1 / -4 / -6 Description of phenomenon: This is a system error in ITRON. This phenomenon may occur when the exclusion function of ITRON is used. Possible causes: A software bug or an illegal operation of ITRON. (2) Mailbox creation error Error No. -2 / -3 / -5 / -7 / -21 Description of phenomenon: This is a system error in ITRON. This phenomenon may occur when a function of ITRON called Mailbox is used. Possible causes: A software...
Page 78
— 76 — error point: Indicates the point on the memory where the operation instruction that causes the above general exception is located (program counter). However, an illegal address may be displayed depending on the exception code. access adrs: Indicates the address that is accessed according to the operation instruction that causes the above general exception. However, the address is 0 (zero) and has no meaning if the access is not the cause. Error Code Correspondence...
Page 79
— 77 — (8) error no. 180: Reservation instruction code exception (9) error no. 1A0: Slot illegal instruction exception Description of phenomenon: These exceptions occur when an illegal instruction is performed. Possible causes: It is hard to think that this phenomenon is caused by software, because these errors occur due to an internal operation of the CPU. This phenomenon is apt to occur when backup of RAM is not performed normally and the memory has been changed. It is possible that the...
Page 80
— 78 — 10. IC DATA ■ MAIN PCB (E820-1 PCB) 1. ALVCH16244 (IC13, 17) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 1OE 1Y1 1Y2 GND 1Y3 1Y4 VCC2Y1 2Y2 GND 2Y3 2Y4 3Y1 3Y2 GND 3Y3 3Y4 VCC4Y1 4Y2 GND 4Y3 4Y4 4OE 2OE 1A1 1A2 GND 1A3 1A4 VCC2A1 2A2 GND 2A3 2A4 3A1 3A2 GND 3A3 3A4 VCC4A1 4A2 GND 4A3 4A4 3OE 1OE 1A1 1A2 1A3 1A41Y1 1Y2 1Y3 1Y4 1 47 46 44 43 2 3 5 6 2OE 2A1 2A2 2A3 2A42Y1 2Y2 2Y3 2Y4 48 41 40 38 37 8 9 11...