Casio Qt 6100 Service Manual
Here you can view all the pages of manual Casio Qt 6100 Service Manual. The Casio manuals for Cash Register are available online for free. You can easily download all the documents as PDF.
Page 2
CONTENTS QT-6100 PAGE 1. SPECIFICATIONS .........................................................................................1 2. INITIALIZATION ............................................................................................5 3. DISASSEMBLY .............................................................................................9 4. ASSEMBLY .................................................................................................15 5. OPTION INSTALLATION...
Page 3
— 1 — 1. SPECIFICATIONS 1-1. Electrical Specifications 1-2. Environmental specifications 1-3. Main LSI specifications • CPU Name HD6417751RF240 (SH-4) Number of control bit 32 bits • I/O controller Name D784215AGC2728EUA Number of control bit 16 bits • Gate array Name UPD65945GJ-P16-JEU • SDRAM Name HY5V52ALFP-H-C Capacity 256 Mbits • Flash ROM Name 29PL127J60TFI13004 Capacity 128 Mbits • Display controller Name SM712GX04LF02-BA • Ethernet controller Name LAN91C113-NE...
Page 4
— 2 — 1-5. I/O Ports COM port (D sub 9pin) x 3 LAN port (Ethernet 10BASE-T/100BASE-TX) x 1 CF CARD slot x 1 Drawer port x 2 • LCD Display Name NL8060BC31-27 Size 12.1 inch SVGA TFT panel Resolution 800 x 600 Interface CMOS 6 bits Colors 262,144 colors • Touch Panel Name N010-0550-T711 Size 12.1 inch • Panel brightness control 1 x VR controller • Power supply External adaptor "ADP820AA" • Cleck key Magnetic ibutton prove "94-J-04" 1-4. Devices...
Page 5
— 3 — DEVICE NAME MODEL NOTE • Magnet i-Button QT-6011DLS • Display set for customer QT-6060D Connect to Com 3 • Display cable for customer QT-6061CB (for mounting to the base) • Display 5-meter cable for customer QT-6062CB • Slip printer SP-1300 Connect to Com 2, 3 • Slip printer cable PRT-CB-8C Length 1.5m • Remote printer UP-250 Connect to Com 2, 3 • Remote printer UP-350 Connect to Com 2, 3 • Remote printer SA-3015 Connect to Com 2, 3 • Remote printer UP-360 Connect to Com...
Page 6
— 4 — CAUTION Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacture’s instructions. VORSICHT ! Explosionsgefahr bei unsachgemäßem Austausch der Batterie. Ersatz nur durch denselben oder einen vom Hersteller empfohlenen gleichwertigen Typ. Entsorgung gebrauchter Batterien nach Angaben des Herstellers. ADVARSEL ! Lithiumbatteri - Eksplosionsfare ved fejlagtig...
Page 7
— 5 — Copyright(C) 2004 CASIO COMPUTER CO.,LTD. All rights reserved. ROM VER.xxxxxx xxxx CREATE xxxx-xx-xx xx:xx QT-6100 x.xx APL VER. xxxxxx xxxx Version INITC 7 8 9 4 5 6 1 2 3 0 OK 2. INITIALIZATION 2-1. MACHINE INITIALIZATION 2-1-1. How to initialize the terminal Preparation: 1. All peripheral devices and terminals should be turned off. 2. Connect all of the peripheral devices (such as printer, display etc.) to terminal. • In case of wire inline: 3. Connect all terminals by inline....
Page 8
— 6 — • Case 2: Terminal ID = “2” ~ “32” * The IP address of each terminal should be the unique number from 192.168. 0. 1 to 192.168.255.255. Declare terminal configuration ———Enter date if it is wrong. ——— Enter time if it is wrong. ——— Within 12 characters ——— Master / Backup master / Satellite / Self master ——— “Check Cluster ID” is always 0 ——— No printer / UP-350 / UP-360 / SA-3015 / UP-250 for R/J or Order printer. ——— No printer / SA-3015 / SP-1300 ——— Press to...
Page 9
— 7 — 2-1-3. How to flag clear the terminal (or INIT2) Preparation: 1. All peripheral devices and this terminal should be turned off. 2. Check the connection of all peripheral devices (such as printer, display etc.) of this terminal. 3. Check the connection of this terminal to inline. Operation: 4. Turn on all peripheral devices of this terminal. 5. Turn on this terminal with pressing the key. 6. Press key. FC Copyright(C)2004 CASIO COMPUTER CO.,LTD. All rights...
Page 10
— 8 — 2-2-2. IPL Operation xxxxxxx xxxxxxx xxxxxxx xxxxxxx xxxxxxx xxxxxxx xxxxxxx xxxxxxxIPL :CF CARD IPL :COM1 PORT xxxxxxx xxxxxxx xxxxxxx IPL :COM1 PORT 115200 bps 57600 bps 56000 bps 34800 bps 19200 bps 9 600 bps CANCEL xxxxxxx xxxxxxx xxxxxxx xxxxxxx xxxxxxx CANCEL START 2. If you choose COM port or IN LINE port, select baud rate of the IPL source device. 3. Press the key to proceed, in case of downloading via inline, automatic ID definition is made by this timing. So press...