— 29 — No Device to be checked Operation Note Page 1 Batch test 1 2 Test Device : RAM, FLASH, Display, 32 Print, Time, Drawer 2 Batch test 2 3 Test Device : Display, Back light 32 3 RAM WRITE/READ test n011 33 4 RAM READ only test n111 33 5 FLASH Check SUM test n512 34 6 FLASH CLEAR/WRITE/READ test n612 34 7 CF-CARD WRITE/READ test pn013 35 8 CF-CARD READ only test pn113 35 9 CF-CARD CLEAR test pn213 36 10 CF-CARD CLEAR&WRITE/READ test pn313 36 11 LCD test n021 37 12 LCD calibration test 221 38 13 Back light OFF test 121 38 14 Remote Cust DISP test bn023 39 15 External printer print test x1x2x3n03d 40 16 RS232C PORT test xn04d 41 17 RS232C PORT batch test 40 42 18 Ethernet test m0a51 43 19 MAC Address SET x0951 44 20 Time setting x1x2x3x4x5x60a70 46 21 Time display 70 46 22 Drawer open test xn091 46 23 Buzzer test n092 47 24 OBR test 95 47 25 MCR test 96 48 26 Charging test 99 50 7-5. Check item The following test can be checked in the diagnostic test.
— 30 — 7-6. Operation of each test [ 1 ] Batch test 1 [Function] RAM test, FLASH test, display test, test print, time setting and drawer open test are performed continuously. Make sure to connect the printer to COM1. [Operation] Refer to the page for the details of the following tests. Operation : 2 ST The following tests are performed automatically. (1) RAM test : WRITE/READ all block test (2) FLASH : Check SUM test (3) Test print (4) Times setting : Set the following data. Arranged data : 2001 December 31, 23:59’30 (5) Drawer open : Opens all drawer. Enters the wait mode for the input of [OK] or [NG] by the operator after drawer open. (6) Receipt issuance [LCD] *When normally printed BATC H 2 RAM WR OK FLASH CHK SUM OK BBBBBBBBBBBBBBBBBBBB *8,888,88 DA TE 01/12/31 TIME 23:59-30 DRW ALL OK END 2 Print T est [Print] *When normally printed BA TC H 2 RAM WR OK FLASH CHK SUM OK DATE 01/12/31 TIME 23:59-30 Please Hit Key OK->1 NG->9 DRW ALL OK END 2 [Print] *When normally printed [ 2 ] Batch test 2 [Function] LCD display test and backlight test are performed continuously. [Operation] Refer to the page for the details of the following tests. Operation : 3 ST The following tests are performed automatically. (1) LCD test : Enters the wait mode for the input of [OK] or [NG] by the operator after the test. "OK" = 1, "NG" = 9 (2) Backlight OFF test : Turns the backlight off. Enters the wait mode for the input of [OK] or [NG] by the operator after the backlight turns off. *Since the backlight is turned off, "Please Hit Key..." cannot be seen. "OK" = 1, "NG" = 9 (3) Receipt issuance [LCD] *When normally printed BA TCH 3 Please Hit Key OK->1 NG->9 LCD OK Please Hit Key OK->1 NG->9 BACK LIGHT OK END 3 Waiting for the input of [OK] o r [NG] for the LCD test. Waiting for the input of [OK] or [NG] for the backlight. * When this appears, the backlight is turned o ff . BATC H 3 LCD OK BACK LIGHT OK END 3
— 31 — [ 3 ] RAM WRITE/READ test [Function] WRITE/READ test for RAM is performed. A counter is displayed for RAM test as follows. [Operation] Operation : n 0 1 1 ST n: 01 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) [LCD] RAM n011 RAM WR OK END n011 [PRINT] NOTE: Prints the address of the error in case the test ended with an error. Prints the address of the error in case the test ended with an error. RAM n011 RAM WR N G END n011 [ 4 ] RAM READ ONLY test [Function] READ ONLY test for RAM is performed Note that WRITE test (n011) must be performed right before this test. [Operation] Operation : n 1 1 1 ST n: 01 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) [LCD] RAM n111 RAM RD OK END n111 RAM n111 RAM RD O K END n111 NOTE: Prints the address of the error in case the test ended with an error. Prints the address of the error in case the test ended with an error. [PRINT]
— 32 — [ 5 ] FLASH Check SUM test [Function] This test will check SUM test for FLASH is performed. [Operation] Operation : n 5 1 2 ST n: 01 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) [LCD] [PRINT] FLASH 512 FLASH CHK SUM OK END 512 FLASH 512 FLASH CHK SUM OK END 512 [ 6 ] FLASH CLEAR WRITE/READ test [Function] The CLEAR & WRITE/READ test for FLASH is performed. After deleting the memory by CLEAR, WRITE/READ test is performed. Note: since this test cannot backup the program, you need to perform IPL again after the test. When the memory in the FLASH memory is cleared (by the CLEAR test), the program is cleared also. [Operation] Operation : n 6 1 2 ST n: 01 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) [LCD] NG and the address are displayed if WRITE cannot be done normally. NG and the address are printed if WRITE cannot be done normally. [PRINT] FLASH 612 FLASH WR ERASE PGM OK END 612 FLASH 612 FLASH WR ERASE PGM OK END 612
— 33 — [ 7 ] CF-CARD WRITE/READ test [Function] This test will check the write/read test (connection test) for CF-CARD. Perform the CF-CARD clear test, before start of this test. Note that this test does not ensure the data inside the CF-CARD as well as its performance. [Operation] Operation : p n 0 1 3 ST p : designates PCMCIA SLOT 0 = CF 1 = PCMCIA n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) [LCD] NG and the address are displayed if WRITE cannot be done normally. [PRINT] CF-CARD pn013 CF WR OK END pn013 CF pn013 CF WR OK END pn013 NG and the address are printed if WRITE cannot be done normally. [ 8 ] CF-CARD READ ONLY test [Function] This test will check the read only test for CF-CARD. Perform the CF-CARD write test, before start of this test. Note that this test does not ensure the data inside the CF-CARD as well as its performance. [Operation] Operation : p n 1 1 3 ST p: designates PCMCIA SLOT 0 = CF 1 = PCMCIA n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) [LCD] NG and the address are displayed if READ cannot be done normally. NG and the address are printed if WRITE cannot be done normally. CF-CARD pn1 13 CF RD OK END pn1 13 CF-CARD pn113 CF RD OK END pn1 13 [PRINT]
— 34 — [ 9 ] CF-CARD CLEAR test [Function] This test will check the clear test for CF-CARD. Note that this test does not ensure the data inside the CF-CARD as well as its performance. [Operation] Operation : p n 2 1 3 ST p: designates PCMCIA SLOT 0 = CF 1 = PCMCIA n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) [LCD] NG and the address are displayed if CLEAR cannot be done normally. NG and the address are printed if WRITE cannot be done normally. CF-CARD pn213 CF CLR OK END pn213 CF-CARD pn213 CF CLR OK END pn213 [PRINT] [ 10 ] CF-CARD CLEAR WRITE/READ test [Function] The CLEAR & WRITE/READ test for CF-CARD is performed. After deleting the memory by CLEAR, WRITE/READ test (connection test) is performed. Note that this test does not ensure the data inside the CF-CARD as well as its performance. [Operation] Operation : p n 3 1 3 ST p: designates PCMCIA SLOT 0 = CF 1 = PCMCIA n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) [LCD] NG and the address are displayed if WRITE cannot be done normally. [PRINT] CF-CARD pn313 CF CLR&WR OK END pn313 CF-CARD pn313 CF CLR&WR OK END pn313 NG and the address are printed if WRITE cannot be done normally.
— 35 — [ 11 ] LCD test [Function] This test will check the LCD display. In case of one time check only, the test can be ended by the judgment (OK or NG) of the opera- tor. The display can be switched by the touch of the panel. The display will not change to the next one unless the panel is touched. [Operation] Press [OK] key or [NG] key to end the test when performing one time check. "OK" = 1, "NG" = 9 Operation : n 0 2 1 ST n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) [LCD] GreenBlueReverse checkRedWhiteBlackTo uch any placein the panel. Touch any place in the panel. Touch any placein the panel.Touch any place in the panel.Touch any placein the panel.Touch any placein the panel. Check (blackand white) Shows the following colors and patterns in the display in the order of black, white, red, green, blue, check and reverse check. Returns to the normal display after the test, and waits for the input of [OK] or [NG] by the operator (in case of one time check). In case of continuous check, the test is ended manually upon the input of [ESC] key. LCD n021 LCD OK END n021 [PRINT] LCD n021 LCD OK END n021
— 36 — [ 13 ] LCD Backlight OFF test [Function] This is a test for the LCD backlight. The test ends upon judgment of the operator between [OK] and [NG]. [Operation] Press [OK] key or [NG] key to end the test when performing one time check. "OK" = 1, "NG" = 9 Operation : 1 2 1 ST [LCD] [PRINT] BACK LIGHT 121 BACK LIGHT OK END 121 BACK LIGHT 121 BACK LIGHT OK END 121 [ 12 ] LCD calibration test [Function] This will test the calibration of the LCD (touch panel). * Perform the calibration in the diagnostic mode even when the product is in the market. Make sure to backup the register data when necessary. [Operation] A cross appears at the following four coordinates in the panel one by one. When a cross at a certain coordinate is touched, the next coordinate will show another cross there. (X,Y) = (100,100), (100,500), (700,100), (700,500) Operation : 2 2 1 ST [LCD] T OUCH ST ART 221 (X1,Y1) : (XXX,XXX) (X2,Y2) : (XXX,XXX) (X3,Y3) : (XXX,XXX) (X4,Y4) : (XXX,XXX) END 221 [PRINT] T OUCH ST ART 221 (X1,Y1) : (XXX,XXX) (X2,Y2) : (XXX,XXX) (X3,Y3) : (XXX,XXX) (X4,Y4) : (XXX,XXX) END 221 Displays data 1 for calibration Displays data 2 for calibration Displays data 3 for calibration Displays the position of the forth coordinate (performs cali- bration)
— 37 — [ 14 ] Remote Cust DISP test [Function] This test will check whether REMOTE DISP can be displayed. Make sure to connect REMOTE DISP to COM3. In case of one time check only, the test can be ended by the judgment (OK or NG) of the opera- tor. Pastel green (white plus green) appears as the backlight, which turns off upon the end of the test. * When changing the baud rate, make sure to change the REMOTE DISP setting. [Operation] Press [OK] key or [NG] key to end the test when performing one time check. "OK" = 1, "NG" = 9 Operation : b n 0 2 3 ST b: Baud rate selection 0 = 19.2 Kbps, 1 = 9600 bps n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) When performing continuous check, the same test character data is sent at a certain interval. When the test is ended manually upon the input of [ESC] key, the display is cleared and the backlight turns off. In case of one time check, the display is cleared and the backlight turns off after the judgment ([OK] or [NG]) of the operator. [LCD] REMOTE DISP na23 REMOTE DISP OK END na23 REMOTE DISP na23 REMOTE DISP OK END na23 [REMOTE DISP] ABCDEFGHIJKLMNOP QRSTUVWXYZabcdef 0,1,2,3,4,5,6,7,8,9, [PRINT]
— 38 — [ 15 ] External printer print test [Function] This test will check the print test for the RS232C I/F printer. Connect the printer to the COM which is to be tested. [Operation] Operation : x1 x2 x3 n 0 3 d ST X1: Print test pattern (0 = A pattern, 1 = B pattern) X2: Port selection (1 = COM1, 2 = COM2, 3 = COM3) X3: Baud rate selection (1 = 4800 bps, 2 = 9600 bps, 3 = 19.2 kbps) n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) d: Printer type selection (1 = RJ, 2 = SLIP) Note that some printers cannot use certain baud rates. Refer to the list below. When changing the baud rate, make sure to change the setting for the printer also. A patternB pattern 19.2 Kbps 9600 bps 4800 bps SLIP PRINTER (SP1300) RJ PRINTER (UP250/350/360) BBBBBBBBBBBBBBBBBBBBB *8,888,88BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB [LCD] PR T xxxn03d END xxxn03d Error display When the printer is not connected NON PRINTER ERR [PRINT] Printing pattern is the following 2 types. The number of lines : 40 lines for RJ and 35 lines for SLIP.