      No    Device to be checked  Operation   Note  Page
      1  Batch test 1    2  Test Device : RAM, FLASH, Display,   32
             Print, Time, Drawer  
      2  Batch test 2    3   Test Device : Display, Back light  32
      3  RAM WRITE/READ test n011    33
      4  RAM READ only test  n111    33
      5  FLASH Check SUM test  n512    34
      6 FLASH CLEAR/WRITE/READ test  n612     34
      7  CF-CARD WRITE/READ test  pn013     35
      8  CF-CARD READ only test  pn113     35
      9  CF-CARD CLEAR test  pn213    36
      10 CF-CARD CLEAR&WRITE/READ test pn313     36
      11  LCD test    n021    37
      12  LCD calibration test  221    38
      13  Back light OFF test  121    38
      14  Remote Cust DISP test  bn023    39
      15  External printer print test  x1x2x3n03d     40
      16  RS232C PORT test  xn04d    41
      17  RS232C PORT batch test  40    42
      18  Ethernet test    m0a51    43
      19  MAC Address SET  x0951    44
      20  Time setting   x1x2x3x4x5x60a70     46
      21  Time display    70    46
      22  Drawer open test  xn091    46
      23  Buzzer test    n092    47
      24  OBR test    95    47
      25  MCR test    96    48
      26  Charging test    99    50
    7-5. Check item
       The following test can be checked in the diagnostic test. 
    						
    							
    — 30 —
    7-6. Operation of each test 
    [ 1 ] Batch test 1
    [Function]
      RAM  test,  FLASH  test,  display  test,  test  print,  time  setting  and  drawer  open  test  are  performed 
    continuously.
      Make sure to connect the printer to COM1.
    [Operation]
    Refer to the page for the details of the following tests.
      Operation :  2  ST
    The following tests are performed automatically.
    (1)  RAM test : WRITE/READ all block test
    (2)  FLASH : Check SUM test
    (3)  Test print
    (4)  Times setting : Set the following data.
          Arranged data : 2001 December 31, 23:59’30
    (5)  Drawer open : Opens all drawer.
        Enters the wait mode for the input of [OK] or [NG] by the operator after drawer open.
    (6)  Receipt issuance
    [LCD]
    *When normally printed
    BATC H    2  
    RAM WR    OK
    FLASH CHK SUM  OK
     
    BBBBBBBBBBBBBBBBBBBB     
                 *8,888,88
    DA TE   01/12/31 
    TIME 
      23:59-30  
    DRW ALL    OK 
    END   
    2  Print 
    T
    est
    [Print]
    *When normally printed
    BA TC H    2  
    RAM WR    OK
     
    FLASH CHK SUM  OK
    DATE   01/12/31 
    TIME 
      23:59-30 
    Please Hit Key  OK->1  NG->9  
    DRW ALL    OK 
    END   
    2 
    [Print]
    *When normally printed
    [ 2 ] Batch test 2
    [Function]
      LCD display test and backlight test are performed continuously.
    [Operation]
    Refer to the page for the details of the following tests.
      Operation :  3  ST
    The following tests are performed automatically.
    (1)  LCD test : 
        Enters the wait mode for the input of [OK] or [NG] by the operator after the test.
        "OK" = 1, "NG" = 9
    (2)  Backlight OFF test : 
          Turns the backlight off.
          Enters the wait mode for the input of [OK] or [NG] by the operator after the backlight turns off.
          *Since the backlight is turned off, "Please Hit Key..." cannot be seen.
       "OK" = 1, "NG" = 9
    (3)  Receipt issuance
    [LCD]
    *When normally printed
    BA TCH    3  
    Please Hit Key  OK->1  NG->9 
    LCD   OK
    Please Hit Key  OK->1  NG->9  
    BACK LIGHT  OK 
    END   
    3  Waiting for the input of [OK] o
    r
    [NG] for the LCD test.
    Waiting for the input of [OK] or
    [NG] for the backlight.
    * When this appears, the backlight
    is turned o ff
    .
    BATC H    3  
    LCD   OK 
    BACK LIGHT  OK 
    END   
    3  
    						
    							
    — 31 —
    [ 3 ] RAM WRITE/READ test
    [Function]
      WRITE/READ test for RAM is performed.
      A counter is displayed for RAM test as follows.
    [Operation]
      Operation :  n  0  1  1  ST
    n:  01 = One time check (can be omitted)
      not 0 = Continuous check (To stop the test, press "ESC" key)
    [LCD]
    RAM    n011 
    RAM WR       OK 
    END   
    n011
    [PRINT]
    NOTE:  Prints the address of the error in case the test ended 
    with an error.
    Prints the address of the error in case the test ended with an 
    error.
    RAM  n011
    RAM WR       N
    G
    END   
    n011
    [ 4 ] RAM READ ONLY test
    [Function]
      READ ONLY test for RAM is performed
      Note that WRITE test (n011) must be performed right before this test.
    [Operation]
      Operation :  n  1  1  1  ST
    n:  01 = One time check (can be omitted)
      not 0 = Continuous check (To stop the test, press "ESC" key)
    [LCD]
    RAM    n111 
    RAM RD       OK 
    END   
    n111
    RAM    n111
    RAM RD       O
    K
    END   
    n111
    NOTE:  Prints the address of the error in case the test ended 
    with an error.
    Prints the address of the error in case the test ended with an 
    error.
    [PRINT] 
    						
    							
    — 32 —
    [ 5 ] FLASH Check SUM test
    [Function]
      This test will check SUM test for FLASH is performed.
    [Operation]
      Operation :  n  5  1  2  ST
    n:  01 = One time check (can be omitted)
      not 0 = Continuous check (To stop the test, press "ESC" key)
    [LCD]
    [PRINT]
    FLASH  512
    FLASH CHK SUM  OK
     
    END   
    512
    FLASH  512
    FLASH CHK SUM  OK
    END   
    512
    [ 6 ] FLASH CLEAR WRITE/READ test
    [Function]
      The CLEAR & WRITE/READ test for FLASH is performed.
      After deleting the memory by CLEAR, WRITE/READ test is performed.
      Note: since this test cannot backup the program, you need to perform IPL again after the test. 
    When the memory in the FLASH memory is cleared (by the CLEAR test), the program is 
    cleared also. 
    [Operation]
      Operation :  n  6  1  2  ST
    n:  01 = One time check (can be omitted)
      not 0 = Continuous check (To stop the test, press "ESC" key)
    [LCD]
    NG  and  the  address  are  displayed  if  WRITE  cannot  be  done 
    normally.
    NG  and  the  address  are  printed  if  WRITE  cannot  be  done 
    normally.
    [PRINT]
    FLASH     612
    FLASH WR ERASE PGM  OK
     
    END     
    612
    FLASH    612
    FLASH WR ERASE PGM  OK
     
    END     
    612 
    						
    							
    — 33 —
    [ 7 ] CF-CARD WRITE/READ test
    [Function]
      This test will check the write/read test (connection test) for CF-CARD.
      Perform the CF-CARD clear test, before start of this test.
      Note that this test does not ensure the data inside the CF-CARD as well as its performance.
    [Operation]
      Operation :  p  n  0  1  3  ST
    p :  designates PCMCIA SLOT
      0 = CF
      1 = PCMCIA
    n:  0 = One time check (can be omitted)
      not 0 = Continuous check (To stop the test, press "ESC" key)
    [LCD]
    NG  and  the  address  are  displayed  if  WRITE  cannot  be  done 
    normally.
    [PRINT]
    CF-CARD  pn013
    CF WR    OK 
    END   
    pn013
    CF   pn013
    CF WR    OK 
    END   
    pn013
    NG  and  the  address  are  printed  if  WRITE  cannot  be  done 
    normally.
    [ 8 ] CF-CARD READ ONLY test
    [Function]
      This test will check the read only test for CF-CARD.
      Perform the CF-CARD write test, before start of this test.
      Note that this test does not ensure the data inside the CF-CARD as well as its performance.
    [Operation]
      Operation :  p  n  1  1  3  ST
    p:  designates PCMCIA SLOT
      0 = CF
      1 = PCMCIA
    n:  0 = One time check (can be omitted)
      not 0 = Continuous check (To stop the test, press "ESC" key)
    [LCD]
    NG  and  the  address  are  displayed  if  READ  cannot  be  done 
    normally.
    NG  and  the  address  are  printed  if  WRITE  cannot  be  done 
    normally.
    CF-CARD  pn1 13
    CF RD    OK 
    END   
    pn1 13
    CF-CARD  pn113
    CF RD    OK 
    END   
    pn1 13
    [PRINT] 
    						
    							
    — 34 —
    [ 9 ] CF-CARD CLEAR test
    [Function]
      This test will check the clear test for CF-CARD.
      Note that this test does not ensure the data inside the CF-CARD as well as its performance.
    [Operation]
      Operation :  p  n  2  1  3  ST
    p:  designates PCMCIA SLOT
      0 = CF
      1 = PCMCIA
    n:  0 = One time check (can be omitted)
      not 0 = Continuous check (To stop the test, press "ESC" key)
    [LCD]
    NG and the address are displayed if CLEAR cannot be done 
    normally.
    NG  and  the  address  are  printed  if  WRITE  cannot  be  done 
    normally.
    CF-CARD  pn213
    CF CLR    OK 
    END   
    pn213
    CF-CARD  pn213
    CF CLR    OK 
    END   
    pn213
    [PRINT]
    [ 10 ] CF-CARD CLEAR WRITE/READ test
    [Function]
      The CLEAR & WRITE/READ test for CF-CARD is performed.
      After deleting the memory by CLEAR, WRITE/READ test (connection test) is performed.
      Note that this test does not ensure the data inside the CF-CARD as well as its performance.
    [Operation]
      Operation :  p  n  3  1  3  ST
    p:  designates PCMCIA SLOT
      0 = CF
      1 = PCMCIA
    n:  0 = One time check (can be omitted)
      not 0 = Continuous check (To stop the test, press "ESC" key)
    [LCD]
    NG  and  the  address  are  displayed  if  WRITE  cannot  be  done 
    normally.
    [PRINT]
    CF-CARD  pn313
    CF CLR&WR  OK
     
    END   
    pn313
    CF-CARD  pn313
    CF CLR&WR  OK
     
    END   
    pn313
    NG  and  the  address  are  printed  if  WRITE  cannot  be  done 
    normally. 
    						
    							
    — 35 —
    [ 11 ] LCD test
    [Function]
      This test will check the LCD display.
      In case of one time check only, the test can be ended by the judgment (OK or NG) of the opera-
    tor.
      The  display  can  be  switched  by  the  touch  of  the  panel. The  display  will  not  change  to  the  next 
    one unless the panel is touched.
    [Operation]
      Press [OK] key or [NG] key to end the test when performing one time check.
     "OK" = 1, "NG" = 9
      Operation :   n  0  2  1  ST
    n:  0 = One time check (can be omitted)
      not 0 = Continuous check (To stop the test, press "ESC" key)
    [LCD]
    GreenBlueReverse 
    checkRedWhiteBlackTo
    uch any placein the panel. Touch any place
    in the panel. Touch any placein the panel.Touch any place
    in the panel.Touch any placein the panel.Touch any placein the panel.
    Check (blackand white)    
      Shows  the  following  colors  and  patterns  in  the  display  in  the  order  of  black,  white,  red,  green, 
    blue, check and reverse check.
      Returns to the normal display after the test, and waits for the input of [OK] or [NG] by the operator (in 
    case of one time check).
      In case of continuous check, the test is ended manually upon the input of [ESC] key.
    LCD  n021
    LCD 
      OK 
    END   
    n021
    [PRINT]
    LCD  n021
    LCD    OK 
    END   
    n021 
    						
    							
    — 36 —
    [ 13 ] LCD Backlight OFF test
    [Function]
      This is a test for the LCD backlight.
      The test ends upon judgment of the operator between [OK] and [NG].
    [Operation]
      Press [OK] key or [NG] key to end the test when performing one time check.
      "OK" = 1, "NG" = 9
      Operation :  1  2  1  ST
    [LCD]
    [PRINT]
    BACK LIGHT 121
    BACK LIGHT  OK 
    END   
    121
    BACK LIGHT 121
    BACK LIGHT  OK 
    END   
    121
    [ 12 ] LCD calibration test
    [Function]
      This will test the calibration of the LCD (touch panel).
      * Perform  the  calibration  in  the  diagnostic  mode  even  when  the  product  is  in  the  market.  Make 
    sure to backup the register data when necessary.
    [Operation]
      A  cross  appears  at  the  following  four  coordinates  in  the  panel  one  by  one.  When  a  cross  at  a 
    certain coordinate is touched, the next coordinate will show another cross there.
      (X,Y) = (100,100), (100,500), (700,100), (700,500)
      Operation :   2  2  1  ST
    [LCD]
    T OUCH ST ART 221
    (X1,Y1)  : (XXX,XXX)
    (X2,Y2)  : (XXX,XXX)
    (X3,Y3)  : (XXX,XXX)
    (X4,Y4)  : (XXX,XXX)
    END   
     221
    [PRINT]
    T OUCH ST ART 221
    (X1,Y1)  : (XXX,XXX)
    (X2,Y2)  : (XXX,XXX)
    (X3,Y3)  : (XXX,XXX)
    (X4,Y4)  : (XXX,XXX)
    END   
     221
    Displays data 1 for calibration
    Displays data 2 for calibration
    Displays data 3 for calibration
    Displays  the  position  of  the  forth  coordinate  (performs  cali-
    bration) 
    						
    							
    — 37 —
    [ 14 ] Remote Cust DISP test
    [Function]
      This test will check whether REMOTE DISP can be displayed.
      Make sure to connect REMOTE DISP to COM3.
      In case of one time check only, the test can be ended by the judgment (OK or NG) of the opera-
    tor.
      Pastel  green  (white  plus  green)  appears  as  the  backlight,  which  turns  off  upon  the  end  of  the 
    test.
      * When changing the baud rate, make sure to change the REMOTE DISP setting.
    [Operation]
      Press [OK] key or [NG] key to end the test when performing one time check.
     "OK" = 1, "NG" = 9
      Operation :  b  n  0  2  3  ST
    b:  Baud rate selection
    0 = 19.2 Kbps, 1 = 9600 bps
    n:  0 = One time check (can be omitted)
      not 0 = Continuous check (To stop the test, press "ESC" key)
      When  performing  continuous  check,  the  same  test  character  data  is  sent  at  a  certain  interval. 
    When  the  test  is  ended  manually  upon  the  input  of  [ESC]  key,  the  display  is  cleared  and  the 
    backlight turns off.
      In case of one time check, the display is cleared and the backlight turns off after the judgment ([OK] 
    or [NG]) of the operator.
    [LCD]
    REMOTE DISP na23
    REMOTE DISP  OK 
    END   
    na23
    REMOTE DISP na23
    REMOTE DISP  OK 
    END   
    na23
    [REMOTE DISP]
    ABCDEFGHIJKLMNOP QRSTUVWXYZabcdef
    0,1,2,3,4,5,6,7,8,9,
    [PRINT] 
    						
    							
    — 38 —
    [ 15 ] External printer print test
    [Function]
      This test will check the print test for the RS232C I/F printer.
      Connect the printer to the COM which is to be tested.
    [Operation]
      Operation :   x1  x2  x3  n  0  3  d  ST
    X1: Print test pattern (0 = A pattern, 1 = B pattern)
    X2: Port selection (1 = COM1, 2 = COM2, 3 = COM3)
    X3: Baud rate selection (1 = 4800 bps, 2 = 9600 bps, 3 = 19.2 kbps)
    n:  0 = One time check (can be omitted)
      not 0 = Continuous check (To stop the test, press "ESC" key)
    d:  Printer type selection (1 = RJ, 2 = SLIP)
      Note that some printers cannot use certain baud rates. Refer to the list below.
      When changing the baud rate, make sure to change the setting for the printer also.
    A patternB pattern
    19.2 Kbps 9600 bps 4800 bps
    SLIP PRINTER (SP1300)
    RJ PRINTER (UP250/350/360)
    BBBBBBBBBBBBBBBBBBBBB            *8,888,88BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
    [LCD]
    PR T   xxxn03d
    END    xxxn03d
    Error display
    When the printer is not connected
    NON PRINTER ERR
    [PRINT]
    Printing pattern is the following 2 types.
    The number of lines : 40 lines for RJ and 35 lines for SLIP. 
    						
    All Casio manuals Comments (0)

    Related Manuals for Casio Qt 6100 Service Manual