Home > Canon > Printer > Canon Imageformula Dr C225 User Guide

Canon Imageformula Dr C225 User Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Canon Imageformula Dr C225 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1335 Canon manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							91
    Adjusting the Reduction Ratio
    ###HOME > Chapter 9 Regular Maintenance > Adjusting the Reduction 
    Ratio###
    As the rollers installed in the scanner wear out, scanned images may 
    become stretched in the vertical direction. If this happens, you can reduce 
    the amount of stretching of the image by adjusting the reduction ratio.
    1Start Windows and log in as a user with administrator privileges.
    2Click the Start button, and then click [All Programs], [Canon 
    DR-C225], and [Canon imageFORMULA Utility].
    imageFORMULA Utility starts.
    3Click [CANON DR-C225 USB] and click [Properties].
    Scanner properties are displayed.
     
    						
    							92
    4Click the [Maintenance] tab and then change the value of [Reduction 
    ratio adjustment].
    The adjustment value can be set within the range from -3.0% to 3.0%.
    5Click [OK] to close the scanner properties.
    1Opens the scanner drivers Detail Settings screen.
    See Select document settings on p.52.
    This will open the advanced settings dialog box for the scanner.
    2Click   to display the [Scanner Information] dialog box.
    3Click [Maintenance] to display the [Maintenance] dialog box.
     
    						
    							93
    4Change the value of [Reduction ratio adjustment].
    The adjustment value can be set within the range from -3.0% to 3.0%.
    5Click   to close the [Maintenance] dialog box. 
     
    						
    							94
    Chapter 10 Replacing Consumable 
    Parts
    ###HOME > Chapter 10 Replacing Consumable Parts ###
    When replacing the separation pad, perform the following steps to detach 
    it from and attach it to the unit. 
    When to replace the consumable parts ............................................ 94
    Opening and Closing the Front Unit ................................................. 95
    Replacing the Feed Roller.................................................................. 96
    Replacing the Retard Roller............................................................... 97
    Resetting the Counters ...................................................................... 98
    Auto Power Off Setting..................................................................... 100
    When to replace the consumable parts
    ###HOME > Chapter 10 Replacing Consumable Parts > When to replace 
    the consumable parts###
    The two rollers (feed roller and retard roller) installed in the scanner are 
    consumable parts. The feed roller and retard roller wear with scanning. If 
    the feed roller and retard roller are worn, documents may not feed 
    correctly and paper jams or double-feed errors may occur.
    When more than 100,000 pages have been fed (total number of pages fed 
    by the scanner), a message prompting you to replace the rollers is 
    displayed when the computer is started.
    If this message begins to be displayed at startup, purchase an exchange 
    roller kit and replace the worn parts with the consumable parts included in 
    the kit (feed roller and retard roller). For details on the exchange roller kit, 
    see Exchange roller kit (product code: 5484B001) on p.113.
     
    						
    							95
    Furthermore, the counter in the scanner that records the number of pages 
    fed also needs to be reset when you replace the rollers. (Resetting the 
    Counters on p.98)Opening and Closing the Front Unit
    ###HOME > Chapter 10 Replacing Consumable Parts > Opening and 
    Closing the Front Unit###
    1Open the document feed tray. Press the OPEN button and pull open 
    the front unit toward you.
    The location of each of the consumable parts is shown below.
     
    						
    							96
    2When closing the front unit, make sure that it is completely closed by 
    gently pressing the left and right until you hear a click.
    3Close the document feed tray.
    Replacing the Feed Roller
    ###HOME > Chapter 10 Replacing Consumable Parts > Replacing the 
    Feed Roller###
    1Open the roller cover.
    2Slide the feed roller to the left, and then remove it.
    3Install the new feed roller. When installing the feed roller, align the 
    notch on the roller with the shaft of the front unit.
     
    						
    							97
    4Slide the roller to the right to secure it.
    5Close the roller cover. Make sure that it is completely closed by 
    pressing until you hear a click.
    Replacing the Retard Roller
    ###HOME > Chapter 10 Replacing Consumable Parts > Replacing the 
    Retard Roller###
    1Open the roller cover.
    2Remove the retard roller and then install the new retard roller. When 
    installing the retard roller, align the notch on the roller with the shaft 
    of the main unit.
    3Close the roller cover. Make sure that it is completely closed by 
    pressing until you hear a click.
     
    						
    							98
    Resetting the Counters
    ###HOME > Chapter 10 Replacing Consumable Parts > Resetting the 
    Counters###
    1Start Windows and log in as a user with administrator privileges.
    2Click the Start button, and then click [All Programs], [Canon 
    DR-C225], and [Canon imageFORMULA Utility].
    imageFORMULA Utility starts.
    3Click [CANON DR-C225 USB] and click [Properties].
    The scanner’s properties appear.
     
    						
    							99
    4Click the [Maintenance] tab, and click [Reset].
    The counter for [Current Rollers] resets.
    5Click [OK] to close the scanner properties.
    1Opens the scanner drivers Detail Settings screen.
    See Select document settings on p.52.
    This will open the advanced settings dialog box for the scanner.
    2Click   to display the [Scanner Information] dialog box.
    3Click [Maintenance] to display the [Maintenance] dialog box.
    4Click [Reset].
    5Click   to close the [Maintenance] dialog box. 
     
    						
    							100
    Auto Power Off Setting
    ###HOME > Chapter 10 Replacing Consumable Parts > Auto Power Off 
    Setting###
    The scanner automatically turns off if 4 hours elapse without scanning or 
    another operation being performed.
    To disable this setting, follow the procedure below.
    1Start Windows and log in as a user with administrator privileges.
    2Click the Start button, and then click [All Programs], [Canon 
    DR-C225], and [Canon imageFORMULA Utility].
    imageFORMULA Utility starts.
    3Click [CANON DR-C225 USB] and click [Properties].
    Scanner properties are displayed.
    The Auto Power Off setting is only available in Windows.
     
    						
    All Canon manuals Comments (0)