Page 111

8. Service
Default : ON
COMMUNICATION
BAUDRATE [115200]
INTERFACE STANDARD[RS232]
RS422 TERMINATION [OFF]
NETWORK
Select with↑or↓
then 
 to return
Menu 8-15
8.5.4 Network Configuration
DHCP
Dynamic host configuration protocol. DHCP is a communications protocol that lets network administrators manage
centrally and automate the assignment of IP addresses in an organization’s network. Using the Internet Protocol, each
machine that can connect to the Internet needs a unique IP address. When an organization...

Page 112

8. Service
4. Repeat the above steps for the subnet mask and the default gateway.
5. SelectAPPLYand pressENTERto install the entered addresses.
If a wrong value for an octet is entered, the value will jump automatically to 255.
NETWORK CONFIGURATION
DHCP [ON]
IP ADDRESS 158.150.160.200
SUBNET MASK 158.150.160.201
DEFAULT GATEWAY
158.150.300.300
MAC ADDRESS 01:01:02:DB:FF:89
APPLY
Select with↑or↓
then 
Reprogram with↑or↓,←or→
or numeric keys
’APPLY’ to confirm
 to return
Menu 8-19
8.6 Date and time setup...

Page 113

8. Service
The lamp overview menu will be displayed. (menu 8-23)
This menu indicates :
- The serial number
- The article number of the lamp
-Theruntime
- The remaining run time for a safe operation
- The number of strikes since thefirst start up
- CLO read out: this function can be used to adjust the Z-axis of the lamp.
SERVICE
IDENTIFICATION
CHANGE PROJECTOR ADDRESS
CHANGE CUSTOMER ID
COMMUNICATION
DATE AND TIME
LAMP
DIMMING/CLO
CONVERGENCE
THOMSON WORLDCAM MODE [OFF]
RESET HARDWARE
FACTORY DEFAULTS...

Page 114

8. Service
Dimming/CLO
	




	

		

 
 !#$
!%&$
Image 8-1
Ta r g e t C L O s e t u p
1. Push the cursor key↑or↓to highlightDimming/CLO. (menu 8-25)
2. PressENTERto select.
TheDimming/CLOmenu will be displayed. (image 8-2)
3. Push the cursor key↑or↓to highlightTarget.
4. PressENTERto select.
5. Use the↑or↓keys to change the value.
6. PressENTER.
SERVICE
IDENTIFICATION
CHANGE PROJECTOR ADDRESS
CHANGE CUSTOMER ID
COMMUNICATION
DATE...

Page 115

8. Service
6. PressENTER.
SERVICE
IDENTIFICATION
CHANGE PROJECTOR ADDRESS
CHANGE CUSTOMER ID
COMMUNICATION
DATE AND TIME
LAMP
DIMMING/CLO
CONVERGENCE
THOMSON WORLDCAM MODE [OFF]
RESET HARDWARE
FACTORY DEFAULTS
DIAGNOSIS
Select with↑or↓
then 
 to return
Menu 8-26
Dimming/CLO
	




	

		

 
 !#$
!%&$
Image 8-3
When Mode on [CLO], dimming value will not be taken into account. When changing this value, the new setting
will only be...

Page 116

8. Service
8.10 Convergence
How to adjust
1. Push the cursor key↑or↓to highlightConvergence. (menu 8-28)
2. PressENTERto select.
A convergence pattern will be displayed.
For more information on how to adjust the convergence physically, consult the service and maintenance documents.
3. PressENTERto switch to other patterns.
SERVICE
IDENTIFICATION
CHANGE PROJECTOR ADDRESS
CHANGE CUSTOMER ID
COMMUNICATION
DATE AND TIME
LAMP
DIMMING/CLO
CONVERGENCE
THOMSON WORLDCAM MODE [OFF]
RESET HARDWARE
FACTORY DEFAULTS...

Page 117

8. Service
The Ethernet communication can be lost since the projector’s IP address will be reset to a default IP address
and the DHCP option is set to OFF.
How to return to the default settings
1. Push the cursor key↑or↓to highlightFactory defaults. (menu 8-31)
2. PressENTERto select.
TheFactory defaults confirmationmenu is displayed. (menu 8-32)
3. PressENTERto confirm the reset to the factory defaults.
PressEXITto return without reset to factory defaults.
SERVICE
IDENTIFICATION
CHANGE PROJECTOR ADDRESS...

Page 118

8. Service
2. PressENTERto select.
TheErrorsoverview window will be displayed. (menu 8-36)
3. Use the↑or↓keys to scroll through the list of displayed errors.
4. PressEXITto return to the Diagnosis menu.
DIAGNOSIS
ERRORS
VOLTAGES
TEMPERATURES
FAN SPEEDS
VERSIONS
Select with↑or↓
then 
 to return
Menu 8-35
ERRORS :
Temp Elcabox low
↑,↓, 0, 8 to scroll,
 to return
Menu 8-36
8.13.3 Voltages
The values, even the min and max values given on the printed menu are only given as an indication.
How to show the...

Page 119

8. Service
4. PressEXITto return to the Diagnosis menu.
DIAGNOSIS
ERRORS
VOLTAGES
TEMPERATURES
FAN SPEEDS
VERSIONS
Select with↑or↓
then 
 to return
Menu 8-39
TEMPERATURES
minmaxRack 0
Lamp house 34
Heats. SMPS 2S 51
Heats. SMPS 2P 53
Heats. SMPS 1S 52
Heats. SMPS 1P 50
Heats. PFC 92
Elco box 0
DMD Red 30
DMD Green 53
DMD Blue 31
↑,↓, 0, 8 to scroll,
 to return
Menu 8-40
8.13.5 Fan speeds
The values, even the min values given on the printed menu are only given as an indication.
How to show the fan speed...

Page 120

8. Service
The version indication contains the version number (major.minor version) (e.g. 1.03) followed by a build num-
ber (e.g. 44)
116R59770014 XLM HD30 25/05/2009 