Page 181

11. Lamp
11 . L A M P
Overview
• Lamp menu overview
• Lamp power mode
• Lamp power
• Auto dimming when on Pause
• Auto dimming when No Signal
• Auto dimming when Over-temperature
• CLO mode (Constant light output mode)
• CLO targets
• LPS power
• Lamp identification
• Z-axis adjustment
R5905032 HDX SERIES 23/11/2011
177 

Page 182

11. Lamp
11.1 Lamp menu overview
Overview table
Level 1 Level 2 Level 3
Lamp
Power Power mode
Power
Auto dimming when pause
Auto dimming when No Signal
Auto dimming when Overtemperature
CLO mode
CLO targets
LPS Power
Identification
Z-axis Light output
178
R5905032 HDX SERIES 23/11/2011 

Page 183

11. Lamp
11.2 Lamp power mode
What can be done?
The lamp power mode can be switched betweenNormalandEconomic. When playing in Economic mode, the lamp life time will
be higher than in normal mode.
The counter of the lamp life time counts equal for normal or economic mode but the customer will see that the ageing of the lamp is
lower in economic mode.
Normal : maximum allowed power is fed to the lamp. Maximum light output is reached in this way.
Economic : a reduced wattage is fed to the lamp. Reduced...

Page 184

11. Lamp
11.3 Lamp power
What can be done?
Within a certain power mode, the light output of the lamp can be reduced by reducing the lamp power
How to reduce the power
1. PressMenuto activate the menus and selectLamp→Power→Power.
Image 11-4
Main menu, lamp
Image 11-5
Lamp, power
Image 11-6
Lamp power adjustment
2. Use the◄or►key to change the power value.
The value can be changed between 75 and 100%
180
R5905032 HDX SERIES 23/11/2011 

Page 185

11. Lamp
11.4 Auto dimming when on Pause
About auto dimming when on pause
When the projector is switched to pause, the shutter is closed but the lamp is still running on full power. When auto dimming on
pause is activated, then the lamp power will be reduced from its current value to its minimum value. When returning out of pause
the lamp power is restored to its previous value.
How to set up
1. PressMenuto activate the menus and selectLamp→Power→Auto Dimming when Pause.
Image 11-7
Main menu, lamp
Image...

Page 186

11. Lamp
11.5 Auto dimming when No Signal
About auto dimming
When no signal is detected on the selected input the lamp power will be reduced from the current value to its minimum value. When
the input signal is re-detected, the lamp power is restored to its original value.
This function is a duplicate of the Auto dimming in the Input menu.
How to set up
1. PressMenuto activate the menus and selectLamp→Power→Auto Dimming No Signal.
Image 11-10
Main menu, lamp
Image 11-11
Lamp, power
Image 11-12
Auto...

Page 187

11. Lamp
11.6 Auto dimming when Over-temperature
What can happen?
When an over-temperature is detected, the projector starts dimming the lamp so that the projector can cool down.
How to set up
1. PressMenuto activate the menus and selectLamp→Power→Auto Dimming Overtemperature.
Image 11-13
Main menu, lamp
Image 11-14
Lamp, power
Image 11-15
Auto dimming over-temperature
2. PressENTERto toggle between[On]or[Off].
[On] : when temperature is to high, auto dimming is started.
[Off] : when temperature is to...

Page 188

11. Lamp
11.7 CLO mode (Constant light output mode)
What can be done?
Constant Light Output allows to force a constant light output (set in theCLO Target lumensitem) of the projector over a certain
period. This will eliminate uncontrolled light output drop caused by natural aging of the lamp. The light output is checked every 5
minutes, if the target is not met, the lamp power is adjusted.
Setting CLO off means that the lamp will operate at constant power (no power adaptation to meet constant light...

Page 189

11. Lamp
Image 11-18
Main menu, lamp
Image 11-19
Lamp, power
Image 11-20
Power, CLO mode
2. PressENTERto toggle between[On]or[Off].
R5905032 HDX SERIES 23/11/2011
185 

Page 190

11. Lamp
11 . 8 C L O t a r g e t s
What must be done?
The light output target can be set. This value will force the projector to produce the target lumens when the CLO mode is set toOn.
How to set the target
1. PressMenuto activate the menus and selectLamp→Power→CLO mode.
Image 11-21
Main menu, lamp
Image 11-22
Lamp, power
Image 11-23
CLO Target lumens setup
2. Use the◄or►key to change the CLO target lumens.