Page 241
MAINTENANCE Table 4-B lists the test points (-5 V, +5 V, -48 V, and GND) for the power supply. The test points are located on the upper-right corner at the front of the cabinet. Table 4-C lists the voltages used by the CPs and symptoms voltages are missing. This information is useful in diagnosing power distribution problems. Table 4-B. Power Supply Test Points that occur when power supply or TestVoltageRemarks Points Limits +5+4.80+5. 15The green LED on the power supply monitors this particular voltage...
Page 242
MAINTENANCE Table 4-C.Circuit Pack Voltage–Symptoms Voltage/+5 volts-5 volts-48 Volts Circuit Pack (Notes)No+5 VNo-5 VNo-48 V Call Proc. (ZTN82,xSystem FailurexEIA FailurexETU Activated ZTN1 28) for RI Memory (ZTN81, xSystem Failure---- ZTN1 27) for RI CPU/Memory (ZTN129,xSystem FailurexEIA FailurexETU Activated for R2, ZTN130 for R3) STARLAN (ZTN84)xCP FailurexCP Failure- - Service Ckt (ZTN85 xSystem Failure ---- or ZTN131 (R3) Hybrid Line (ZTN79)xCP FailurexNo VoicexStation OS Tip/Ring (ZTN78)xCP...
Page 243
MAINTENANCE Each power supply has one green LED on its front that can be seen through the fan assembly. The LED is visible through the ventilation slots on the front cover, but the cover must be removed for diagnostic and service purposes. This LED is always lighted when the system is receiving 5.1 volts power. The LED is dark when there is a failure in the +5 volt power supply or power connections, or when there is a short on the backplane. If the green LED on the power supply is dark, first make sure...
Page 244
MAINTENANCE AC DISTRIBUTION UNIT AC CIRDVARISTOR PWB ASSY CM 538A1S1 SW TO 15A 120 VAC OUTLET GROUND BLOCK Figure 4-8.AC Power Schematic 4-68
Page 245
MAINTENANCE Power Supply Protection Power supply outputs are protected from damage when they are subjected to either momentary or sustained short circuits.“Shutdown” current protection is provided at 125 percent (plus or minus 5 percent) of full load for each dc output. Current foldback is provided for the 90 V ac output. Output power is removed when the output voltage exceeds an internally set trip point. The trip point is set at the factory at +6.25, +0.75 V for the +5.1 V output for all rated line and...
Page 246
MAINTENANCE Power Supply Replacement To replace the power supply, follow these steps: Danger:Hazardous voltages are present on some backplane 1. 2. 3. 4. 5. 6. 7. 8. pins. Unplug power cord from the outlet, and wait at least 5 minutes before removing rear cover or power supply. Remove the front cover of the cabinet. Remove the four No. 6-32 screws at the corners of the fan assembly. Unplug the fan assembly from system power by removing the two modular plugs on the left side of the assembly. Set the fan...
Page 247
MAINTENANCE Fan Assembly Trouble The fans should always be operating when the system is receiving ac power and the cabinet switch is turned on. If the fans are not operating, be sure that the system is receiving ac power. if the system is receiving power and the fans are still not operating, the ac power connection to the fan assembly is faulty or the fans themselves are faulty (for example, burned out motors). To check the ac power connection to the fan assembly, first unplug the power cord, and then...
Page 248
MAINTENANCE Overheating Trouble A clogged or dirty air filter can cause the cabinet to overheat. The cabinet air filter rests on the floor of the cabinet under the CP carrier. The air filter should be inspected on any service call and replaced as needed (with air filter comcode 845948348). Caution: To replace the Warning:Check underneath cabinet for paper and other debris that could clog the air filter and cause the cabinet to overheat. air filter, pinch it in the center and pull straight out. To reduce...
Page 249
MAINTENANCE TEST POINT CABLE CONNECTSI HERE. ACCESS VOLTAGE TESTADDRESS PLUG POSITION POINTS FROM FRONT OF (SLOT 08 NOT USED) CABINET. Figure 4-9.System Cabinet Backplane Wiring Side (Sheet 1 of 2) 4-73