Page 273
MAINTENANCE Figure 4-13.Clearing Switched 3 of 5)Loop Attendant Console Troubles (Sheet 4-96
Page 275
MAINTENANCE NOTES : 1. (a) System defaults to a DTAC when first powered up. (b) You have to remove the DTAC before you can administer the SLAC . (c) System 25 can support 1 or 2 DTAC or 1 or 2 SLAC but not a combination of both. 2. ID names can be assigned for PDCs,Trunks, FPDCs, and DGC groups. (a) (b) (c) (d) 3. You Under Menu =1 or 2 (Port/PDC) Action =90 Assign/Remove IDs 11 characters Under Menu =1 (Port-Trunk Administration) Action= 90 Assign/Remove Trunk IDs 11 characters Under Menu= 5 (FPDC)...
Page 276
MAINTENANCE Special Port Circuit Options for Stations and Trunks Tables 4-E and 4-F provide the special port circuit options that are administered in the system. System defaults and associated action codes applicable to the various port CPS are also shown.Procedures are available in the Administration Manual for logging onto the system and accessing the information shown in Table 4-E. The administrable items shown in Table 4-E should not be changed unless CO and maintenance personnel agree that an item...
Page 277
MAINTENANCE Table 4-F.Applicable Actions for Circuit Pack Options ACTIONS FOR CIRCUIT PACK OPTIONS (See Circuit Pack Options—Table 4-E) CIRCUITCPACTIONS PACKTYPE32 333435363738, ZTN76GS Boardllll ZTN77LS Trunklll l ZTN78Tip/Ring Linell TN742Analog Linellll TN753 DID Trunkllll TN760BTie Trunklllll TN763Aux Trunkll TN767DS1 Interfacellll Note: TN747 same as ZTN76 and ZTN77. TN746B same as TN742. Data Line Troubles Symptoms: Data terminals connected through the Data Line CP (TN726) are dead or are not...
Page 278
6. 7. 8. 9. 10. 11. 12. 13. 14. If +7 volts are not present, the ADU is not receiving enough power from the data terminal and must be locally powered. If the ADU is powered from a local transformer, make sure that a 3- pair or 2-pair modular cord is connected between the transformer and the ADU. Using a 4-pair modular jack breakout ac voltage between pins 7 and 8 is about 28 volts for an open circuit.box, check to be sure that the about 14 volts under load or Even with alternate power, the data terminal...
Page 279
MAINTENANCE Multiple Troubles or Trouble That Cannot Be Diagnosed Symptoms: Red LED is lighted on all port CPs. SAT displays this message: “FAIL: CPU:ARCHANGELINSANE:CHECK ZTN85: TERMINATOR?”. Procedures: 1. 2. 3. 4. 5. Check that the TDM bus terminator card(s) is installed in the rear pin field(s). Note:The CPU/Memory CP provides built-inbus termination circuitry for one end of the bus, and the TDM bus termination card is used to terminate the other end. Reseat the CPU/Memory and Service CPs (see...
Page 280
MAINTENANCE Symptoms: Red LED is lighted cm several port CPs. Procedures: 1. 2. 3. 4. . Check the power supply to be sure that it is providing correct voltages (see “Power Supply Trouble’ ‘). Check the frontplane connector and the CPU/Memory CP, and replace any faulty unit(s). Reseat any CPs where the red LED is still lighted. After reseating a CP, if the red LED remains lighted, replace the CP. If troubles persist, check the backplane for signs of shorts or other troubles. A port CP with trouble may be...