Page 221
MAINTENANCE ERROR MESSAGE AND DESCRIPTIONPOSSIBLE SOLUTION Trunk Call Dropped: A call thatNormally, no action required; had been up on a trunk for morehowever, ifproblem persists, than 9 hours has been detectedperform trunk test call per Trunk by an audit and dropped. TheTroubles procedure in this Part. port associated with the errorAlso, check the CO disconnect identifies the trunk in question.and trunk timing. Trunk Call Too Long: An auditThis error is removed when a found a call that had been up on...
Page 222
MAINTENANCE ERROR MESSAGE AND DESCRIPTIONPOSSIBLE SOLUTION Unrecognized Command:Recoverable; no action required. (STARLAN Interface CP) This error is anisolated transient condition. User Forced Warm Start: SystemRecoverable; no action required. was warm started through the SAT. Warm Start: Power supply may be out of System was restarted for someregulation (see Figure 4-2). Check reason; translations are okay.remaining errors in the alarm tables for associated problems. Wink Too Short For Valid...
Page 230
MAINTENANCE NOTES : 1. PC should be running NAUCOM, Session, CAM and/or any STARLAN NETWORK compatible emulating program. 2. The green LED lights when the STARLAN CP passes power up. Figure 4-5.Clearing STARLAN Interface Troubles