MAINTENANCE ERROR MESSAGE AND DESCRIPTIONPOSSIBLE SOLUTION DCFailTransientRecord:No action required; this error Indicates a dc power failure.display is a record of the start time of the failure. DC Power Failed: Indicates theCheck the +5 V dc voltage level absence of +5 V dc on a cabinet.on the power supply (see Figure Each cabinet has its own power4-2). supply; therefore, this may not cause a warm start. DC Power Restored:IndicatesIt is possible to produce this error that +5 V dc has been restored.when...
Page 212
MAINTENANCE ERROR MESSAGE AND DESCRIPTIONPOSSIBLE SOLUTION DXS Reset; The DXS console hasRecoverable; no action required. been reset. ElectronicPowerFeed Off, Check the wiring for shorts from Overcurrent:A Hybrid Linethe backplane/SIP up to the (ZTN79) port EPF chip shut down.phone jack. Check the ATL set at Two ports are effected, for the SIP. Try swapping ATL sets. example, 1-2,3-4,5-6,7-8. Error removed if Audit passed and short removed. Audit runs every 4 minutes. Electronic Power Feed Overload:Check...
Page 213
MAINTENANCE ERROR MESSAGE AND DESCRIPTIONPOSSIBLE SOLUTION External Stack Full: (STARLANIf the reset is not successful Interface CP) This error resets thereseat board. If the reseat fails, CP. replace the board. Fault onOutgoingSeizure: Check trunk for slow dial tone; ZTN76/TN747 CO ground was notmore than 10 seconds. Perform detected within a predeterminedtrunktestcall per“Trunk time-frame.ZTN77/747loopTroubles”procedure in this current was not detected within asection.If the problem persists,...
Page 214
MAINTENANCE ERROR MESSAGE AND DESCRIPTIONPOSSIBLE SOLUTION Illegal Instruction: This error isThe Problem could be with the logged when an illegal instructionROM on the CPU/Memory CP. If is encountered by the CPU.the problem persists, check or replace CP. Illegal Interrupt: CPU/Memory CPThe CP may still pass the power- problem.up test for the ROM. Check or replace the CPU/Memory CF. Illegal Port Command: (STARLANRecoverable; no action required. Interface CP) This error is an isolated transient condition....
Page 215
MAINTENANCE ERROR MESSAGE AND DESCRIPTION POSSIBLE SOLUTION Invalid Message Length: The portIf the problem persists, check or CP sent an up-link message that replace the port CP. is not in the expected message set. Invalid Port Board:(Other thanRemove or replace CP with a CPU or Memory) Port CP not board that is supported by System supported by system.25. Invalid Port Message: The port If problem persists, check or CP sent an up-link message that replace the port CP. is not in the expected message set....
Page 216
MAINTENANCE ERROR MESSAGE AND DESCRIPTIONPOSSIBLE SOLUTION Memory Management Error: BusPossible software error.If error that occurs while accessingproblem persists,check or the “other than protected” RAM.replace CPU/Memory CP. A A warm start is logged after thiswarm start or retranslation of the error. system could be a possible fix for this problem. Memory ROM Checksum Error:If this problem persists, replace Memory has failed the ROM test.CPU/Memory CP. Message Corruption: (Other thanIf consistent error...
Page 217
MAINTENANCE ERROR MESSAGE AND DESCRIPTIONPOSSIBLE SOLUTION On-HookBeforeReady To Receive Digits: For a tie trunk with delay dial or winkstart—after the handshake is complete, a 50-ms guard time must pass before digits are received. If the far-end goes on-hook before guard time elapses, this message is logged. On-Hook Before Wink: For a tie trunk with delay dial or wink start—if the far end goes on-hook (possibly indicating the beginning of a rotary dial digit) before the wink handshake is completed, the...
Page 218
MAINTENANCE ERROR MESSAGE AND DESCRIPTIONPOSSIBLE SOLUTION Port CPMissingButCheck CP slot; reseat CP; change “Administered:(OtherthanCP; orremoveCP from CPU/Memory) Translated port CPtranslations. If CP does not pass that CPU cannot access.power-up, replace CP. Port CP Out Of Service: (OtherIf the CP has not been removed thanCPU/Memory)Messageand the problem persists, check occurs when a CP is removed or replace the port CP. from a cabinet. Error removed when the CP passes power-up. Port CP ROM Checksum...
Page 219
MAINTENANCE ERROR MESSAGE AND DESCRIPTIONPOSSIBLE SOLUTION Received Incorrect Number of DID Digits: This error indicates that the CO is set up to send a number of DID digits different from what the switch has been administered to receive.Ensure that trunks are properlytranslated.Notify local CO to verify the correct number of digits to be sent. Test trunk per Figure 4-3. RIMS Insane:Service Circuit or Tone Detector CP problem.If an “RIMS Sane” occurred, the system will remove this error from the...
Page 220
MAINTENANCE ERROR MESSAGE AND DESCRIPTIONPOSSIBLE SOLUTION ServiceCircuitTestFailed: Check TDM bus terminator and Service Circuit demand test failedcabinet interconnect cables. If the on the DTMF receivers.problem persists, replace ZTN85 or ZTN131 (R3). Signaling Lead Fault: AuxiliaryCheckwiring of external Trunk CP is expecting a groundequipment per Figure 4-7. from external equipment but none is detected. SlotConfigurationError:This condition can be resolved by (STARLAN Interface CP) Thismoving the...