    							Installing the MERLIN Identifier System
    2.
    3.
    4.
    Using the modular cords with RJ11 plugs, bridge each
    Central Office line to the MERLIN Controller by plugging
    one end into the MERLIN Identifier Control Unit jacks
    labeled “TO PBX” and the other end into the MERLIN
    Controller jacks labeled “LINES” (see Figure 3).
    Disconnect the station line cords from the MERLIN
    Controller jacks labeled “STATlONS” and plug them into
    the corresponding MERLIN Identifier Control Unit jacks
    labeled “TO STATIONS” (see Figure 4).
    Figure 4.
    Rerouting the Station Lines
    Using the modular cords with RJ45 plugs, bridge each
    station line to the MERLIN Controller by plugging one end
    into the MERLIN Identifier Control Unit jacks labeled
    “FROM PBX” and the other end into the MERLIN Controller
    jacks labeled “STATIONS” (see Figure 4).
    14STEP 3:Wire the MERLIN Identifier Control Unit 
    						
    							Installing the MERLIN Identifier System
    STEP 4:
    Mount the MERLIN
    Identifier Display Units
    MERLIN Identifier Display units can be mounted directly on a wall
    or to the MERLIN telephone. Refer to Figure 5 as you follow the
    instructions to mount the MERLIN Identifier Display units.
    Figure 5.
    Mounting the MERLIN Identifier Display Units
    STEP 4:Mount the MERLIN Identifier Display Units15 
    						
    							Installing the MERLIN Identifier System
    Wall Mounting
    To mount the MERLIN Identifier Display unit to the wall, follow the
    instructions below:
    1.
    2.
    3.
    4.Position the wall mounting bracket on the wall near the
    MERLIN telephone and an AC power outlet, and mark
    points for the pilot holes.
    Remove the wall mounting bracket, drill pilot holes, and
    install the plastic screw anchors.
    Reposition the wall mounting bracket over screw anchors
    and drive the #6 x 1/2-inch self-tapping screws through the
    mounting holes and into the anchors.
    Align the slots on the back of the MERLIN Identifer Display
    with the three prongs on the wall mounting bracket, and
    snap the MERLIN Identifier Display into place.
    Telephone Mounting
    To mount the MERLIN Identifier Display unit to a MERLIN
    telephone, follow the manufacturer’s instructions included with the
    telephone mounting bracket.
    16STEP 4:Mount the MERLIN Identifier Display Units 
    						
    							Installing the MERLIN Identifier System
    STEP 5:
    Wire the MERLIN
    Identifier Display Units
    Refer to Figure 6 as you follow the instructions to connect the
    MERLIN Identifier Display unit to the MERLIN telephone and to
    a PC.
    Figure 6.
    Wiring the MERLIN Identifier Display Units
    STEP 5:Wire the MERLIN Identifier Display Units17 
    						
    							Installing the MERLIN Identifier System
    Connecting the Display to a
    MERLIN Telephone
    Follow the instructions below to wire MERLIN Identifier Display
    units to MERLIN telephones:
    Remove the station cord from the back of the MERLIN
    telephone and plug it into the MERLIN Identifier Display
    jack labeled “LINE.”
    1.
    2.
    3.
    1.
    Plug one end of the 18 inch, modular cord with RJ45 plugs
    into the MERLIN Identifier Display jack labeled “TEL” and
    the other end into the jack on the back of the MERLIN
    telephone.
    Plug the 9 volt 200 milliampere transformer power cord into
    the MERLIN Identifier Display port labeled “9V-DC” and the
    transformer into an AC power outlet.
    The MERLIN Identifier Display should display the following
    to show that it is powered on:
    MERLIN IDENTIFIER
    Connecting the Display to a PC
    A PC running a purchased, Windows™-based contact
    management software application or asynchronous
    communications software can be used to capture Caller ID
    information from a MERLIN Identifier Display. The MERLIN
    Identifier Displays come with a modular cord and an RJ11-to-DB9
    adapter. If your PC’s serial port requires a DB25 connection, you
    must purchase a DB9-to-DB25 adapter.
    To connect a PC to a MERLIN Identifier Display, refer to Figure 6
    and follow the steps below:
    Unplug the the MERLIN Identifier Display power cord and
    switch off the PC.
    18STEP 5:Wire the MERLIN Identifier Display Units 
    						
    							Installing the MERLIN Identifier System
    2.
    3.
    4.
    5.
    n
    n
    Connect one end of the modular cord into the MERLIN
    Identifier Display jack labeled “RS232” and the other end to
    the jack in the RJ11-to-DB9 adapter.
    Connect the DB9 adapter to the PC’s serial port, either
    COM1 or COM2.
    Start the PC and either the contact management software
    application or the asynchronous communications software.
    If you use the contact management software
    application, follow the manufacturer’s instructions to
    set up and operate the software.
    If you use your own communications software, set up
    the PC’s communications software as a direct
    connection with the parameters as given under
    “Connecting the Administrative PC” in “STEP 6,” and
    start the communications program capture feature.
    Reconnect the MERLIN Identifier Display power cord.
    STEP 6:Connecting
    Administrative Components
    You can administer the MERLIN Identifier system from either an
    Administrative Display using a PC Keyboard or from an
    Administrative PC running asynchronous communications
    software. Refer to Figure 7 as you follow the instructions to
    connect your administrative components.
    WARNING:
    To prevent damage to the MERLIN Identifier Control Unit and
    equipment you connect to it, remove their power cords before
    connecting them.
    STEP 6:
    Connecting Administrative Components19 
    						
    							Installing the MERLIN Identifier System
    Figure 7.
    Connecting Administrative Components
    Connecting the Administrative
    Keyboard and Display
    To connect the Administrative Keyboard and Display to the
    MERLIN Identifier Control Unit:
    1.
    2.Plug the Administrative Keyboard cord to the MERLIN
    Identifier Control Unit port labeled “Keyboard.” Use the
    supplied adapter cable if your keyboard cord ends with a
    5-pin DIN connector.
    If no shelf or desk space is available for the Administrative
    Keyboard, mount the keyboard wall mounting brackets on
    the wall near the MERLIN Identifier Control Unit using the
    #6 x 1/2-inch self-tapping screws (supplied) and plastic
    wall anchors.
    20STEP 6:
    Connecting Administrative Components 
    						
    							Installing the MERLIN Identifier System
    3.
    4.
    5.
    6.
    7.
    8.Follow the instructions under “STEP 4” to mount the MERLIN
    Identifier Display to be used as the Administrative Display.
    Plug one end of the modular cord into the Administration
    Display jack labeled “LINE” and the other end into the
    MERLIN Identifier Control Unit jack labeled “Admin
    Display.”
    Slide the Administrative Mode switch to the “Keybd/Display”
    position.
    Plug the transformer power cord into the MERLIN Identifier
    Administration Display port labeled “9V-DC” and the
    transformer into an AC power outlet.
    The MERLIN Identifier Control Unit power LED should light
    and the 
    ENTER PASSWORD prompt should display on the
    Administrative Display screen.
    Switch on the power to the MERLIN Identifier Control Unit.
    Install the MERLIN Identifier Control Unit cover by sliding it
    into position from the top.
    Connecting the Administrative PC
    The Administrative PC can be situated in the same room as the
    MERLIN Identifier Control Unit or located in another room. If you
    want to locate the Administrative PC in another room, you will
    need to install a jack near the MERLIN Identifier Control Unit and
    another jack near the Administrative PC, and run an inside wire
    between the two jacks before using the procedure that follows.
    To connect an Administrative PC to the MERLIN Identifier Control
    Unit:
    1.
    labeled “RS232 Admin.”
    Connect the RJ45-to-DB9 adapter labeled “Serial Port
    Controller” to the MERLIN Identifier Control Unit port
    STEP 6:Connecting Administrative Components
    21 
    						
    							Installing the MERLIN Identifier System
    2.
    3.
    4.
    5.Connect one of the following RJ45 adapters to the
    Administrative PC’s serial port:
    n
    n
    n
    nFor a 9-pin COM port, connect the RJ45-to-DB9
    adapter labeled “Serial Port PC.”
    For a 25-pin COM port, connect the RJ45-to-DB25
    adapter labeled “Serial Port PC.”
    Do one of the following:
    If the Administrative PC is in the same room as the
    MERLIN Identifier Control Unit, connect a modular
    cord with RJ45 plugs directly between the “Serial
    Port Controller” adapter and the “Serial Port PC”
    adapter.
    If the Administrative PC is in a separate room,
    connect a modular cord with RJ45 plugs directly
    between the “Serial Port Controller” adapter on the
    MERLIN Identifier Control Unit and its designated
    wall jack. Then connect a modular cord with RJ45
    plugs directly between the “Serial Port PC” adapter
    on the Administrative PC’s serial port and its
    designated wall jack.
    Slide the MERLIN Identifier Control Unit Administrative Mode
    switch to the “RS232 Admin” position.
    Start the Administrative PC and the communications
    software.
    22STEP 6:Connecting Administrative Components 
    						
    							Installing the MERLIN Identifier System
    6.
    7.
    8.Set up the Administrative PC’s communications software as
    a direct connection with the following parameters:
    Port:   COM1 or COM2 to match physical connection
    Speed:   1200 bps
    Data length:   8 bits
    Stop Bits:   1 bit
    Parity:   none
    Duplex:   full
    Plug the 9 volt 1 ampere transformer power cord into the
    MERLIN Identifier Control Unit port labeled “9V-DC” and
    the transformer into an AC power outlet.
    The MERLIN Identifier Control Unit power LED should light
    and the 
    ENTER PASSWORD prompt should display on the
    Administrative PC screen.
    Install the MERLIN Identifier Control Unit cover by sliding
    into position from the top.
    Connecting a Serial Printer
    Depending on your MERLIN Identifier system requirements, you
    may also want to connect a serial printer to the MERLIN Identifier
    Control Unit to collect Caller ID information.
    The serial printer can be situated in the same room as the
    MERLIN Identifier Control Unit, or located in another room. If you
    want to locate the serial printer in another room, you will need to
    install a jack near the MERLIN Identifier Control Unit and another
    jack near the serial printer, and run an inside wire between the
    two jacks before using the procedure that follows.
    To connect the serial printer to the MERLIN Identifier Control Unit,
    refer to Figure 7 and follow the steps below:
    1.
    Unplug the the MERLIN Identifier Control Unit power cord
    and the printer’s or PC’s power cord.
    STEP 6:Connecting Administrative Components23 
    						