ATT Merlin Identifier Installation Administration Manual
Here you can view all the pages of manual ATT Merlin Identifier Installation Administration Manual. The ATT manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 21
Installing the MERLIN Identifier System 2. 3. 4. Using the modular cords with RJ11 plugs, bridge each Central Office line to the MERLIN Controller by plugging one end into the MERLIN Identifier Control Unit jacks labeled “TO PBX” and the other end into the MERLIN Controller jacks labeled “LINES” (see Figure 3). Disconnect the station line cords from the MERLIN Controller jacks labeled “STATlONS” and plug them into the corresponding MERLIN Identifier Control Unit jacks labeled “TO STATIONS” (see Figure...
Page 22
Installing the MERLIN Identifier System STEP 4: Mount the MERLIN Identifier Display Units MERLIN Identifier Display units can be mounted directly on a wall or to the MERLIN telephone. Refer to Figure 5 as you follow the instructions to mount the MERLIN Identifier Display units. Figure 5. Mounting the MERLIN Identifier Display Units STEP 4:Mount the MERLIN Identifier Display Units15
Page 23
Installing the MERLIN Identifier System Wall Mounting To mount the MERLIN Identifier Display unit to the wall, follow the instructions below: 1. 2. 3. 4.Position the wall mounting bracket on the wall near the MERLIN telephone and an AC power outlet, and mark points for the pilot holes. Remove the wall mounting bracket, drill pilot holes, and install the plastic screw anchors. Reposition the wall mounting bracket over screw anchors and drive the #6 x 1/2-inch self-tapping screws through the mounting holes...
Page 24
Installing the MERLIN Identifier System STEP 5: Wire the MERLIN Identifier Display Units Refer to Figure 6 as you follow the instructions to connect the MERLIN Identifier Display unit to the MERLIN telephone and to a PC. Figure 6. Wiring the MERLIN Identifier Display Units STEP 5:Wire the MERLIN Identifier Display Units17
Page 25
Installing the MERLIN Identifier System Connecting the Display to a MERLIN Telephone Follow the instructions below to wire MERLIN Identifier Display units to MERLIN telephones: Remove the station cord from the back of the MERLIN telephone and plug it into the MERLIN Identifier Display jack labeled “LINE.” 1. 2. 3. 1. Plug one end of the 18 inch, modular cord with RJ45 plugs into the MERLIN Identifier Display jack labeled “TEL” and the other end into the jack on the back of the MERLIN telephone. Plug the...
Page 26
Installing the MERLIN Identifier System 2. 3. 4. 5. n n Connect one end of the modular cord into the MERLIN Identifier Display jack labeled “RS232” and the other end to the jack in the RJ11-to-DB9 adapter. Connect the DB9 adapter to the PC’s serial port, either COM1 or COM2. Start the PC and either the contact management software application or the asynchronous communications software. If you use the contact management software application, follow the manufacturer’s instructions to set up and operate the...
Page 27
Installing the MERLIN Identifier System Figure 7. Connecting Administrative Components Connecting the Administrative Keyboard and Display To connect the Administrative Keyboard and Display to the MERLIN Identifier Control Unit: 1. 2.Plug the Administrative Keyboard cord to the MERLIN Identifier Control Unit port labeled “Keyboard.” Use the supplied adapter cable if your keyboard cord ends with a 5-pin DIN connector. If no shelf or desk space is available for the Administrative Keyboard, mount the...
Page 28
Installing the MERLIN Identifier System 3. 4. 5. 6. 7. 8.Follow the instructions under “STEP 4” to mount the MERLIN Identifier Display to be used as the Administrative Display. Plug one end of the modular cord into the Administration Display jack labeled “LINE” and the other end into the MERLIN Identifier Control Unit jack labeled “Admin Display.” Slide the Administrative Mode switch to the “Keybd/Display” position. Plug the transformer power cord into the MERLIN Identifier Administration Display port...
Page 29
Installing the MERLIN Identifier System 2. 3. 4. 5.Connect one of the following RJ45 adapters to the Administrative PC’s serial port: n n n nFor a 9-pin COM port, connect the RJ45-to-DB9 adapter labeled “Serial Port PC.” For a 25-pin COM port, connect the RJ45-to-DB25 adapter labeled “Serial Port PC.” Do one of the following: If the Administrative PC is in the same room as the MERLIN Identifier Control Unit, connect a modular cord with RJ45 plugs directly between the “Serial Port Controller” adapter and...
Page 30
Installing the MERLIN Identifier System 6. 7. 8.Set up the Administrative PC’s communications software as a direct connection with the following parameters: Port: COM1 or COM2 to match physical connection Speed: 1200 bps Data length: 8 bits Stop Bits: 1 bit Parity: none Duplex: full Plug the 9 volt 1 ampere transformer power cord into the MERLIN Identifier Control Unit port labeled “9V-DC” and the transformer into an AC power outlet. The MERLIN Identifier Control Unit power LED should light...