Have a look at the manual Aleratec 111 HDD Copy Cruiser HighSpeed WL User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 61 Aleratec manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
www.aleratec.com35 Using the HDD Copy Cruiser High-Speed WL Main Menu Setup - Stop Motor Time This function will allow you to view and set the stop motor time. 1. In the Setup menu, use the arrow buttons (or) to select “Stop Motor Time”. The following screen will be displayed. 2. Press OK to select. The following information will be displayed. 3. Use the arrow buttons () to toggle through the available options. Once you change a configuration option, remember to press OK to save it. ESC OK[ 6. Setup ] 8. Stop Motor Time ESC OK[ Stop Motor Time ] 5 seconds
www.aleratec.com36 Using the HDD Copy Cruiser High-Speed WL Main Menu Setup - Advanced Setup The “Advanced Setup” menu contains additional configuration options for the HDD Copy Cruiser High-Speed WL. ESC OK[ 6. Setup ] 9. Advanced Setup
www.aleratec.com37 Using the HDD Copy Cruiser High-Speed WL Main Menu Setup - Advanced Setup A. Wait HDD Time This function uses the specified wait time before automatically starting the function that was selected. A1. To edit the Wait HDD Time function, select “Wait HDD Time” and press OK. A2. The following information will be displayed. A3. Use the arrow buttons () to toggle through the available options. Once you change a configuration option, remember to press OK to save it. ESC OK[ Advanced Setup ] 1. Wait HDD Time ESC OK[ Wait HDD Time ] 15 seconds
www.aleratec.com38 Using the HDD Copy Cruiser High-Speed WL Main Menu Setup - Advanced Setup B. Copy HPA area The HPA is a hidden data region defined in ATA/ATAPI-4. This area is not usually accessible to the operating system or software applications. The HDD Copy Cruiser High-Speed WL supports the copying of data from this hidden area. B1. To edit the Copy HPA area function, select “Copy HPA area” and press OK. B2. The following options will be displayed. B3. Press OK to select your perfered option. After changing a setting, remember to press OK to save it. ESC OK[ Advanced Setup ] 2. Copy HPA area ESC OK[ Copy HPA Area ] No ESC OK[ Copy HPA Area ] Setting HPA ESC OK[ Copy HPA Area ] Copy and Settings
www.aleratec.com39 Using the HDD Copy Cruiser High-Speed WL Main Menu Setup - Advanced Setup C. Adjust Clock This function will allow you to change the time and date. A1. To edit the Wait HDD Time function, select “Adjust Clock” and press OK. A2. The following information will be displayed. A3. Use the arrow buttons () to toggle through the available options. Once you change a configuration option, remember to press OK to save it. ESC OK[ Advanced Setup ] 3. Adjust Clock ESC OK2014/10/07 09:50:00
www.aleratec.com40 Using the HDD Copy Cruiser High-Speed WL Main Menu Setup - Restore Default The Restore Default function will reset all settings to their original values. 1. In the Setup menu, use the arrow buttons (or) to select “Restore Default”. The following screen will be displayed. 2. Press OK to select. The following screen will be displayed. 3. Press OK to clear the parameter to default settings. ESC OK[ 6. Setup ] 10. Restore Default ESC OKWarning: Clear Parameter To Default?
www.aleratec.com41 Using the HDD Copy Cruiser High-Speed WL Main Menu Log Manager This function will allow you to access the Log Manager’s password protected Advanced Functions. 1. With the source and target HDDs loaded use the arrow buttons (or) to select “Log Manager”. The following screen will be displayed. 2. Press OK to select. The following information will be displayed. Press OK again to access the Advanced Function menu. 3. You will be prompted to enter a password. Select characters by pressing the arrow buttons (or). Press to scroll through numbers first. Press to scroll through letters first. Press OK to move to the next character. Note: The default password is 123456 ESC OK2014/10/07 09:50 7. Log Manager ESC OK[ Log #1 - #32 ] 1. Advanced Function ESC OKEnter Password => _
www.aleratec.com42 Using the HDD Copy Cruiser High-Speed WL Main Menu Log Manager - Advanced Function A. Clear ALL Log This function will allow you to clear all logs. A1. After entering your password, the following screen will be displayed. A2. Press OK to select. The following information will be displayed. A3. Press OK to clear the log, or press ESC to go back. ESC OK[ Advanced Setup ] 1. Wait HDD Time ESC OKWarning: Clear ALL log?
www.aleratec.com43 Using the HDD Copy Cruiser High-Speed WL Main Menu Log Manager - Advanced Function B. Setup Password This function will allow you to set a new password. B1. After entering your password, the following screen will be displayed. B2. To setup a new password, scroll to “Setup Password”. The following screen will be displayed. B3. Press OK to enter a new password. Select characters by pressing the arrow buttons (or). Press to scroll through numbers first. Press to scroll through letters first. Press OK to move to the next character. B4. Once you are finished entering your new password, press OK to save. ESC OKEnter Password => _ ESC OK[ Advanced Setup ] 1. Wait HDD Time ESC OK[ Advanced Setup ] 2. Setup Password
www.aleratec.com44 Using the Aleratec HDD Duplicator Logging Software Please read this Software User Guide thoroughly before using this product. Getting Started 1. Connect your HDD Copy Cruiser High-Speed WL to your computer using the supplied USB cable. 2. Turn on the HDD Copy Cruiser High-Speed WL. 3. Load the Aleratec installation and user guide CD into the DVD/CD Rom drive in your PC. Double click on Aleratec Logging and Monitoring Software from the menu and follow on-screen prompts to install the application. 4. Open the Aleratec Monitoring Software by double-clicking the Aleratec Logging icon either on your desktop or start menu. 5. The main screen of the software is divided into two sections. The empty chart displays the current ongoing process. The Log Data section displays the history of all processes.