Page 21

 21
LS1+TIMER 
・Fastening operation will start at the time of LS1 input, and the line control timer will also start.   
When the preset fastening number is attained, COUNT OK will result, and then LS1 input will 
be accepted only after COUNT OK terminal output (output duration time can be set by using 
COUNT OK output timer). 
・If the line control timer has become time-out before completing the preset fastening number, 
COUNT NOK will result.  In this case, fastening operation will finish when COUNT OK...

Page 22

 22
 
W.SELECT 
・Fastening operation will start upon WORK SELECT 1~4 input. 
・When the preset fastening number is attained, Work No. specific COUNT OK will be output 
(output duration time can be set by using COUNT OK output timer). 
・When the preset fastening number is not attained at the time of WORK switching input OFF 
condition, COUNT NOK will result.  
 ・  In addition, when WORK SELECT input is turned OFF before attaining the preset fastening 
number, COUNT NOK will result....

Page 23

 23
 
W. SEL. TIMING (WORK No. switching timing) 
Initial Setting  : NO (without timing) 
・This setting is common among WORK No. 1~4. 
Particulars 
NO (without timing) 
・WORK No. switching will take effect immediately after WORK SELECT input condition has been 
changed. 
YES (with timing)
 
・The following timings will be interposed at the time of WORK No. switching. 
 ①At the time of Front Panel RESET key input 
 ②At the time of RESET terminal input 
 ③At the time when COUNT OK lamp is turned off....

Page 24

 24
 
 
KEY BZ VOL. (Buzzer Sound at Key Operation) 
Initial Value  : 5 
Setting Range  : 0~5 
・This buzzer sounds to give operators power-on and/or key-in signals. 
0: no sound  1: low-volume~5: high-volume 
・This setting is common among WORK No. 1~4. 
・Be sure to set to Level 5 when you use the low-tone buzzer. 
 
 
DISPLAY (LCD Display Selection) 
Select any of the following LCD display options to view under Operation Mode: 
Selections: Standard (initial setting) or Fas. time   
 
Standard 
・Items on...

Page 25

 25
AUTOMATIC SET UP (automatic setting) 
This Automatic Set Up function performs automatic pressure setting by utilizing the pressure 
variation obtained through Tool free running and practical fastening operation. 
 
(1)Tool Selection
 
 
 
 
 
 
 
①Select Tool you will use and press  key. 
(2)Measurement of Pressure at Free Running
 
 
 
 
 
 
 
①Run your Tool for 2~3 seconds under no-load, and then release the lever. 
 (Run your Tool with the socket and bit removed from Tool end.) 
②The buzzer sounds...

Page 26

 26  
TIMER 
 
 
 
 
 
 
 
 
 
 
 
 
 
①INITIAL. E [msec] (initial error detection timer) 
Initial Value  : 0 
Setting Range  : 0~9999 (0 setting when you do not use this function) 
Functions 
・Timer will start at the time when the pressure attained the preset fastening start pressure, and 
error will be detected when the preset shut-off pressure is attained before time-out. 
・This is on-a-WORK No. basis setting. 
 
②CYCLE. E. [msec] (cycle error detection timer) 
Initial Value  : 0 
Setting Range  :...

Page 27

 27  
⑤ON [msec] (ON Timer) 
Initial Value  : 0 
Setting Range  : 0~9999 
・This is on-a-WORK No. basis setting. 
 
⑥OFF [msec] (OFF Timer) 
Initial Value  : 0 
Setting Range  : 0~9999 
・This is on-a-WORK No. basis setting. 
 
⑦OK [msec] (Fastening OK Output Timer) 
Initial Value  : 1000 
Setting Range  : 0~9999(Output will be held up to the next fastening start point in the case of   
0 setting.) 
Functions 
・This is fastening OK terminal’s output time 
・Output will be turned OFF even before time-out...

Page 28

 28
TERMINAL ALLOCATION(Terminal Block Input/Output Alternatives) 
(1) Choice among terminal block input alternatives 
・Choose input signal alternatives for use in Input Terminal Block IN1~6. 
・This setting is common among WORK No. 1~4. 
Initial Setting 
IN1:LS1  IN2:RESET         IN3:NOK RESET 
IN4:QL    IN5:WORK SELECT A   IN6:WORK SELECT B 
Alternatives (Pick up 6 among the following alternatives) 
 ●LS1          ●LS2         ●LS3         ●RESET  ●NOK  RESET     
●QL            ●PASS       ●W.SEL.A...

Page 29

 29
 
(1) Choice among terminal block output alternatives 
・Choose output signal alternatives for use in Output Terminal Block OUT1~5. 
・This setting is common among WORK No. 1~4. 
Initial Setting 
OUT1:
COUNT OK 
OUT2:
COUNT NOK 
OUT3:OK    (Fastening
 OK) 
OUT4:NOK  (Fastening
 NOK) 
OUT5:BUZZER  (
Buzzer Output) 
Alternatives (Pick up 5 among the following alternatives) 
●
COUNT OK    ●COUNT NOK ●OK     ●NOK 
●BUZZER
    ●WARNING      
●W.1.C.OK ●W.2.C.OK ●W.3.C.OK ●W.4.C.OK 
  ●CYCLE  COUNT  1...

Page 30

 30
WIRING DIAGNOSIS(Terminal Block Wiring Diagnosis) 
 
Wiring diagnosis will be performed through monitoring input status of external wires mated to 
UTM-1500 Input Terminal Block and through Output Terminal Block forced output. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
(1)Input Wiring Diagnosis 
・○  indicate the absence of Terminal Block input 
・●  indicate the presence of Terminal Block input 
 
 
(2)Output Wiring Diagnosis 
・Select any of the terminals by touching .    The selected terminal will accompany “_“...