    LS1+TIMER 
    ・Fastening operation will start at the time of LS1 input, and the line control timer will also start.   
    When the preset fastening number is attained, COUNT OK will result, and then LS1 input will 
    be accepted only after COUNT OK terminal output (output duration time can be set by using 
    COUNT OK output timer). 
    ・If the line control timer has become time-out before completing the preset fastening number, 
    COUNT NOK will result.  In this case, fastening operation will finish when COUNT OK 
    judgment is given through NOK handling. 
    ・Note that COUNT OK terminal output holding (set value: 0) can not be selected when this 
    function is in use.
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    TIMER 
    ・In this method, Limit Switch will not be provided, and the line control timer gets started by 
    utilizing the initial fastening judgment or QL wrench input. 
    ・COUNT OK judgment will be given when the preset fastening number is attained, and the next 
    coming work fastening operation will become ready when COUNT OK output (output duration 
    time can be set by using COUNT OK output timer) is turned OFF. 
    ・If the line control timer has become time-out before completing the preset fastening number, 
    COUNT NOK will result.  In this case, fastening operation will finish when COUNT OK 
    judgment is given through NOK handling. 
    ・Note that COUNT OK terminal output holding (set value: 0) can not be selected when this 
    function is in use. 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    Work 
    Work flow 
    NOK handling range 
    Line control timer 
    Initial fastening judgment 
    Judgment 
    Operating range
    Work 
    Work flow 
    NOK handling range 
    LS1 
    Line control timer Judgment
    Operating range 
    Alarm output timer 
    Alarm output 
    Alarm output timer 
    Alarm output  
    						
    							 22
     
    W.SELECT 
    ・Fastening operation will start upon WORK SELECT 1~4 input. 
    ・When the preset fastening number is attained, Work No. specific COUNT OK will be output 
    (output duration time can be set by using COUNT OK output timer). 
    ・When the preset fastening number is not attained at the time of WORK switching input OFF 
    condition, COUNT NOK will result.  
     ・  In addition, when WORK SELECT input is turned OFF before attaining the preset fastening 
    number, COUNT NOK will result. 
     
     
     
     
     
     
     
     
     
    WorkWork flow 
    NOK handling 
    range WORK 1 operating range Judgment 
    WORK 4 COUNT OK output
    Preset number completed 
    WORK 4 
    Fastening Operation 
    WORK SELECT 4 input 
    WORK SELECT 1 in
    put
    COUNT OK output timer duration 
    In the case of COUNT OK  In the case of COUNT NOK  
    						
    							 23
     
    W. SEL. TIMING (WORK No. switching timing) 
    Initial Setting  : NO (without timing) 
    ・This setting is common among WORK No. 1~4. 
    Particulars 
    NO (without timing) 
    ・WORK No. switching will take effect immediately after WORK SELECT input condition has been 
    changed. 
    YES (with timing)
     
    ・The following timings will be interposed at the time of WORK No. switching. 
     ①At the time of Front Panel RESET key input 
     ②At the time of RESET terminal input 
     ③At the time when COUNT OK lamp is turned off. 
     
     
    ERROR (refastening at the time of fastening error) 
    Initial Setting  : REFASTENING (fastening NOK will be cleared upon refastening operation 
    start) 
    ・Select refastening at the occasion of fastening errors: 
    ・This setting is common among WORK No. 1~4.
     
    Particulars 
    REFASTENING (Fastening NOK clearing at refastening operation start) 
    ・Fastening error will be cleared at the time of refastening operation start. 
    NO RE-F (refastening will not be accepted until Fastening NOK RESET) 
    ・When a fastening error (initial error/cycle error) occurs under this setting, the next fastening 
    signals cannot be accepted until such error condition has been cleared by inputting Fastening 
    NOK RESET.    When TM Type Tool or Standard Tool is in use, VALVE ON status will be 
    kept ON until such error condition has been cleared, and the next fastening operation cannot 
    be accepted without error cancellation. 
     
    CHECK BZ VOL. (Fastening Operation Check Buzzer Sound) 
    Initial Value  : 5 
    Setting Range  : 0~5 
    ・This buzzer sounds to give operators a count-down signal at the time of Fastening OK or QL 
    input. 
    0: no sound  1: low-volume~5: high-volume 
    ・The buzzer will turn ON for 1-pulse duration at count-down and turn ON for 2-pulse duration at 
    Count OK. 
    ・This setting is common among WORK No. 1~4. 
    ・Be sure to set to Level 5 when you use the low-tone buzzer. 
     
    NOK BZ VOL. (NOK Buzzer Sound) 
    Initial Value  : 5 
    Setting Range  : 0~5 
    ・This buzzer sounds to give operators Fastening NOK or Count NOK signals. 
    0: no sound  1: low-volume~5: high-volume 
    ・This setting is common among WORK No. 1~4. 
    ・Be sure to set to Level 5 when you use the low-tone buzzer. 
      
    						
    							 24
     
     
    KEY BZ VOL. (Buzzer Sound at Key Operation) 
    Initial Value  : 5 
    Setting Range  : 0~5 
    ・This buzzer sounds to give operators power-on and/or key-in signals. 
    0: no sound  1: low-volume~5: high-volume 
    ・This setting is common among WORK No. 1~4. 
    ・Be sure to set to Level 5 when you use the low-tone buzzer. 
     
     
    DISPLAY (LCD Display Selection) 
    Select any of the following LCD display options to view under Operation Mode: 
    Selections: Standard (initial setting) or Fas. time   
     
    Standard 
    ・Items on display 
     WORK No., Pressure Detecting Status, Current Pressure Value, Judgment, Fastening Time and 
    Pulse No. 
     [Example] 
     
     
     
     
     
    Fas. Time (Fastening time) 
    ・Items on display 
     Only fastening time will be displayed at full scale using all 4 lines. 
    [Example] 
     
     
     
     
     
     
     
    Display switching is allowable also under Operation Mode.    Switch to “Fas. Time” by pressing 
     for longer than 2 seconds and switch to “Standard” by pressing  for longer than 2 
    seconds. 
     
     
     
    WORK  No.1 
    P1:○  P2:○ 
    P.VALUE:    0.00    MPa 
    OK      1234msec    10PLS 
    						
    							 25
    AUTOMATIC SET UP (automatic setting) 
    This Automatic Set Up function performs automatic pressure setting by utilizing the pressure 
    variation obtained through Tool free running and practical fastening operation. 
     
    (1)Tool Selection
     
     
     
     
     
     
     
    ①Select Tool you will use and press  key. 
    (2)Measurement of Pressure at Free Running
     
     
     
     
     
     
     
    ①Run your Tool for 2~3 seconds under no-load, and then release the lever. 
     (Run your Tool with the socket and bit removed from Tool end.) 
    ②The buzzer sounds when the controller has read pressure value, and the measured pressure 
    value will be on display. 
    ③Run your Tool again under no-load when re-measurement is necessary. 
    ④Press 
      key when pressure value is obtained normally. 
    (3)Measurement of Blow Pressure / Shut-off Pressure (in the case of SHUT-OFF selection) 
     
     
     
     
     
     
    ①Start fastening operation with a bolt seated.  In the case that Shut-off Tool is in use, 
    perform fastening operation until shut-off. 
    ②The buzzer sounds when the controller has read pressure values, and the measured 
    pressure values will be on display. 
    ③Return to ① when re-measurement is necessary, and press 
      key when pressure 
    values are obtained normally. 
    (4)Set Value Display 
     
     
     
     
     
    ①Pressing   key will call up the previous screen (Blow/Shut-off Pressure Measurement). 
    ②Pressing 
      key will call up MENU screen upon rewriting the setting values. 
    ③You may perform re-measurement also at this stage by repeating fastening operation.
     
    *  AUTOMATIC  SET  UP  * 
    Air  Pat  Free  Running 
    0.00  Mpa 
     
    *  AUTOMATIC  SET  UP  * 
    ■SHUT-OFF 
      TM  TYPE 
    NON-SHUT  TYPE
     
    *  AUTOMATIC  SET  UP  * 
    Air  P‘s  during  Blows 
    0.00Mpa~0.00Mpa 
    0.00Mpa
     
    Blow Pressure Range 
    Shut-off Pressure 
    LEVER  ON  :  0.**    Mpa 
    SHUT-OFF  :  0.**    Mpa 
    PULSE  LV  :  0.***  Mpa 
    1-PULSE    :  ****    msec
      
    						
    							 26  
    TIMER 
     
     
     
     
     
     
     
     
     
     
     
     
     
    ①INITIAL. E [msec] (initial error detection timer) 
    Initial Value  : 0 
    Setting Range  : 0~9999 (0 setting when you do not use this function) 
    Functions 
    ・Timer will start at the time when the pressure attained the preset fastening start pressure, and 
    error will be detected when the preset shut-off pressure is attained before time-out. 
    ・This is on-a-WORK No. basis setting. 
     
    ②CYCLE. E. [msec] (cycle error detection timer) 
    Initial Value  : 0 
    Setting Range  : 0~9999 (0 setting when you do not use this function.) 
    Functions 
    ・Timer will start at the time when the pressure attained the preset fastening start pressure, and 
    cycle error will be detected before the preset shut-off pressure is attained. 
    ・This is on-a-WORK No. basis setting. 
     
    ③L. CONTR. [sec] (line control timer) 
    Initial Value  : 100 
    Setting Range  : 1~999 
    Functions 
    ・This function is used to effect fastening number count operation based on timer control. 
    ・This is on-a-WORK No. basis setting. 
     
    ④WARNING [sec] (alarm output timer) 
    Initial Value  : 0 
    Setting Range  : 0~999 
    ・Use this function when an alarm output before line control timer time-out timing is necessary. 
    ・Terminal outputs allocated to alarm outputs will turn ON before the alarm output timer preset 
    time from the line control timer time-out.    Alarm outputs will turn OFF at the time of line 
    control timer time-out timing or at the time of Count OK (line control judgment).   
    ・This is on-a-WORK No. basis setting.
     
     
    *  *  *  TIMER  *  *  * 
    ■INITIAL.E.:   0msec
    CYCLE.E.:        0  msec
    L.CONTR.:    100  sec 
    WARNING  :        0  msec
    ON            :    700  msec
    OFF          :    800  msec
     OK      : 1000  msec
    COUNT  OK:  1000  msec
    1-PULSE  :  10.0  msec
    QL  time  :    100  msec 
    						
    							 27  
    ⑤ON [msec] (ON Timer) 
    Initial Value  : 0 
    Setting Range  : 0~9999 
    ・This is on-a-WORK No. basis setting. 
     
    ⑥OFF [msec] (OFF Timer) 
    Initial Value  : 0 
    Setting Range  : 0~9999 
    ・This is on-a-WORK No. basis setting. 
     
    ⑦OK [msec] (Fastening OK Output Timer) 
    Initial Value  : 1000 
    Setting Range  : 0~9999(Output will be held up to the next fastening start point in the case of   
    0 setting.) 
    Functions 
    ・This is fastening OK terminal’s output time 
    ・Output will be turned OFF even before time-out timing in the case that the next fastening 
    operation gets started during Fastening OK Output. 
    ・This is on-a-WORK No. basis setting. 
     
    ⑧COUNT OK [msec] (Count OK Output Timer) 
    Initial Value  : 1000 
    Setting Range  : 0~9999 (Output will be held up to the next fastening start point in the case of 
    0 setting.)
     
    Functions 
    ・This is Count OK terminal’s output time 
    ・Output time will be 1000msec at the maximum when the next fastening operation got started 
    during Count OK output or when Count OK resulted after Count NOK.    (In the case of less 
    than 1000msec settings, Turn OFF at the time when the preset time has been attained.) 
    ・This is on a WORK No. basis setting 
    ⑨1-PULSE [msec] (Lowest Pulse Range) 
    Setting Range  : 0~9999 
    Functions 
    ・This is Pulse Detection Timer. 
    ・Pulses with a pulse fall time of longer than 1-pulse will be judged as a pulse. 
    ・Perform setting works under Auto Setting or by referring to waveforms saved on PC. 
    ※Pulse detection will sometimes become impossible in the case that Tool of less pneumatic 
    pressure fluctuation type at pulsation (small tool or the like to be more specific) is in use or 
    depending on work conditions. 
    ⑩QL time [msec] (QL Wrench Anti-chattering Timer) 
    Setting Range  : 0~9999 
    Functions 
    ・This setting is specifically designed to avoid duplicate count at one time QL due to chattering 
    during QL wrench operation. 
    ・Even though Input is turned ON within the preset time after QL terminal Input is turned OFF, 
    countdown will not be performed.  
      
    						
    							 28
    TERMINAL ALLOCATION(Terminal Block Input/Output Alternatives) 
    (1) Choice among terminal block input alternatives 
    ・Choose input signal alternatives for use in Input Terminal Block IN1~6. 
    ・This setting is common among WORK No. 1~4. 
    Initial Setting 
    IN1:LS1  IN2:RESET         IN3:NOK RESET 
    IN4:QL    IN5:WORK SELECT A   IN6:WORK SELECT B 
    Alternatives (Pick up 6 among the following alternatives) 
     ●LS1          ●LS2         ●LS3         ●RESET  ●NOK  RESET     
    ●QL            ●PASS       ●W.SEL.A  ●W.SEL.B 
    ●W.SEL.1  ~  W.SEL.4         ●PS 
    Particulars 
    LS1/LS2/LS3 
    ・Limit Switch 1~3.    These inputs are used for line control.    Refer to P16~19 for more details on 
    Line Control. 
    RESET 
    ・Count balance/judgment, fastening judgment and others will be cleared entirely and System 
    will be placed in the initial state at power-on. 
    NOK RESET 
    ・Fastening NOK status will be cleared.    Fastening error conditions like an initial error and 
    cycle error will be cleared. 
    QL 
    ・ Fastening numbers remained due to Tool breakdown or inadvertent fastening omission will 
    be counted down when additional fastening operation has been performed with a 
    micro-switch installed Torque Wrench connected to QL terminal. 
    ・ It will be counted down regardless of operating range. 
    PASS 
    ・Inputting PASS will forcefully bring about COUNT OK status. 
    WORK SELECT A    WORK SELECT B 
    ・These inputs are used to allow work number selection and useful to switch 4 types of works 
    with 2 inputs. 
    ・WORK No. Selection Patterns 
    WORKSELECT-Input Status WORK  No. 
    A  B 
    1  OFF  OFF 
    2  ON  OFF 
    3  OFF  ON 
    4  ON  ON 
    WORK SELECT 1~4 
    ・These inputs are used to allow work number selection and useful to switch 4 types of works 
    with 4 inputs. 
    ・WORK№ Selection Patterns 
    WORKSELECT-Input Status WORK No.
    1 2 3 4 
    1 ON OFF OFF OFF 
    2 OFF ON OFF OFF 
    3 OFF OFF ON OFF 
    4 OFF OFF OFF ON 
    PS・For Air-electric Relay signal inputting.  
    						
    							 29
     
    (1) Choice among terminal block output alternatives 
    ・Choose output signal alternatives for use in Output Terminal Block OUT1~5. 
    ・This setting is common among WORK No. 1~4. 
    Initial Setting 
    OUT1:
    COUNT OK 
    OUT2:
    COUNT NOK 
    OUT3:OK    (Fastening
     OK) 
    OUT4:NOK  (Fastening
     NOK) 
    OUT5:BUZZER  (
    Buzzer Output) 
    Alternatives (Pick up 5 among the following alternatives) 
    ●
    COUNT OK    ●COUNT NOK ●OK     ●NOK 
    ●BUZZER
        ●WARNING      
    ●W.1.C.OK ●W.2.C.OK ●W.3.C.OK ●W.4.C.OK 
      ●CYCLE  COUNT  1  ●CYCLE  COUNT  2 
      ●PULSE  NOS.1      ●PULSE  NOS.2 
    Particulars 
    COUNT OK 
    ・COUNT OK  external output signal 
    ・Output duration can be set on Count OK Output Time Timer. 
    COUNT NOK 
    ・COUNT NOK  external output signal.    This signal will be output when the predetermined 
    fastening number has not been attained before judgment.  
    ・This output signal will be kept on during COUNT NOK. 
    ・This output signal remains on until the remaining fastening number has been cleared by 
    adding fastening operation or OK condition has resulted by using PASS or NOK status has 
    been cleared by RESET inputting. 
    OK 
    ・Fastening OK external output signal 
    ・Output duration can be set on Fastening OK Output Time Timer. 
    NOK (Fastening NOK) 
    ・This signal will be output at the time of an initial or cycle error. 
    ・This output signal remains on until Fastening OK will be given by performing additional 
    fastening operation or error conditions have been cleared by RESET or Fastening NOK 
    RESET inputting. 
    BUZZER(output for Buzzer) 
    ・Use this option when an external buzzer will be used. 
    ・Signal output ON timing is the same as the buzzer mounted on System.    This buzzer does not 
    produce sound at the time of key operation. 
    WARNING(alarm output) 
    ・This signal will be output from the Warning Output Timer’s time-out to Count OK or to Line 
    Control Timer’s time-out. 
    W.※.C.OK  (WORK ※ COUNT OK)    ※:1~4 
    ・Select this output when COUNT OK output becomes necessary on a Work No. basis. 
    CYC.COUNT  1/2    PULS.NOS.  1/2 
    ・This signal will be output when Cycle Count or Cumulative Pulse attained the value preset 
    using Tool management OUT SET. 
      
    						
    							 30
    WIRING DIAGNOSIS(Terminal Block Wiring Diagnosis) 
     
    Wiring diagnosis will be performed through monitoring input status of external wires mated to 
    UTM-1500 Input Terminal Block and through Output Terminal Block forced output. 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    (1)Input Wiring Diagnosis 
    ・○  indicate the absence of Terminal Block input 
    ・●  indicate the presence of Terminal Block input 
     
     
    (2)Output Wiring Diagnosis 
    ・Select any of the terminals by touching .    The selected terminal will accompany “_“ at 
    the bottom. 
    ・Press 
     key to switch between the selected output terminal’s ON/OFF. 
    ・At the start of WIRING DIAGNOSIS screen, OUT 1~5 will be under OFF “○” state and VALVE 
    will be under ON “●” status. 
     
     
     
     
     
    WIRING  DIAGNOSIS 
         1 2 3 4 5 6 V
    IN  :  ○  ○  ●  ●  ○  ○  
    OUT:  ●  ○
     ● ○ ●   ●
    Display Layout 
    1~6:Terminal Block No.(IN1~6・OUT1~5) 
    V:VALVE Terminal 
    ○:Terminal’s input or output is OFF condition. 
    ●:Terminal’s input or output is ON condition.  
    						