    							 31
     
    MEMORY 
     
     
     
     
     
     
    WORK 
    Make a choice among 1, 2, 3, 4, and ALL alternatives by using 
      keys and specify WORK 
    No. to call up on DISPLAY column. 
    When ALL is selected, data pertaining to WORK 1~4 will be displayed altogether. 
    Numbers to be shown in ( )  indicate data number. 
     
    DISPLAY 
    Select any of the items to call up. 
    DATA        :Numeric data in memory will be displayed. 
    ANALSIS  :Mean values and/or sigma values will be displayed. 
    ・When 
      is pressed down, the particulars of the item selected at DISPLAY column according 
    to the Work No. selected at WORK column will be displayed. 
     
    ERASE 
    Make a choice among 1, 2, 3, 4, and ALL (1~4 all inclusive) by using 
      keys and specify 
    WORK No. of which memory data you intend to erase. 
    When 
     is pressed, memory data corresponding to the selected WORK No. will be erased. 
     
     
     
    BAUD  RATE(transmission speed) 
     
     
     
     
     
    Set data transmission speed matching PC you will use. 
     
    Initial Value  : 38400 [bps] 
    Setting Values  : 19200, 38400, 57600, 115200 
     
     
    *  *  *  MEMORY  *  *  * 
    ■WORK    :  1(125) 
    DISPLAY  :  DATA 
    ERASE      :    1 
    *  *  BAUD  RATE  *  * 
     
    BAUD  RATE  :  38400bps  
    						
    							 32
    Tool management(tool management) 
     
    This function is specifically designed to notify operators of Tool maintenance timing, and when the 
    preset Cycle Count or Cumulative Count has been attained, the timing will be notified through the 
    means of LCD display, Buzzer and Terminal Block output. 
    Cycle Count    : Current total fastening number of Tool now in use. 
    “CYC. COUNT” will be indicated on LCD display. 
    Cumulative Count  : Current total pulse number of Tool now in use. 
    “PULS. NOS.” will be indicated on LCD display.
     
     
     
     
     
     
     
    (1)TOOL 
    Make entries necessary to specify Tool; including Tool No. and Model. 
     
     
     
     
     
     
     
    How to make entries 
    ・Put the cursor on any alphanumeric, space, “-”and “.”character arranged on the 3
    rd and 4th lines 
    by moving the arrow key and press 
        key.    Then the character you selected will be put on 
    the cursor position on the TOOL column on the 2
    nd line. 
    ・To erase the last character of TOOL column, touch RESET key. 
    ・To return to Tool Management MENU screen, press 
      key while putting the cursor on END. 
    ・Up to 15 characters can be entered. 
    (2)OUT  SET 
    Enter Cycle Count and Cumulative Pulse Number intended for maintenance works. 
     
     
     
     
     
     
     
    CYC.COUNT1  : Cycle Count 1 
    CYC.COUNT2  : Cycle Count 2 
    Setting Range    : 0~999999 
    You must make setting CYC. COUNT1
    						
    							 33
     
    PULS.NOS.1  : Cumulative Pulse 1 
    PULS.NOS.2  : Cumulative Pulse 2 
    Setting Range    : 0~9999999 pulses 
    You must make setting PULS. NOS. 1 
    						
    							 34  
    (3)CUMULATIVE  COUNT  
    Current Cycle Count and Cumulative Pulse Number Display and Clear: 
     
     
     
     
     
    CYC.COUNT : Current cycle count 
    PULS.NOS. : Current cumulative pulse number 
    CLEAR   : Cycle count and cumulative pulse number clearing 
    ・Selecting CLEAR will call up the following window. 
    ・Selecting YES will clear the current cycle count and cumulative pulse number and then call back 
    CUMULATIVE COUNT screen. 
    ・Selecting NO will call back CUMULATIVE COUNT screen without clearing the numbers. 
     
     
     
     
     
     
     
     
    *  CUMULATIVE  COUNT  *
    ■CYC.COUNT  :   30000
      PULS.NOS.  :    200000
      CLEAR 
    ERASE  COUNT  DATA 
    CONFIRM  AND  GO  ON!
    ■NO 
      YES  
    						
    							 35
    Pressure Value Setting 
    Pressure value setting without using Automatic Setting Function 
     
    (1)In the case of Shut-off Tool (TM) 
        ・Connect Tool in the first place 
        ・Touch 
      key for more than 3 seconds and start “MENU” screen. 
    ・Set TOOL to SHUT-OFF TYPE on “SET UP” screen. 
        ・Then, select “SENSOR”.    Select “NO DISPLAY” when a private pressure sensor will be 
    used and select “DISPLAY” when a digital pressure sensor will be used. 
        ・Return to “MENU” screen by touching 
      key, and touch   key again to return to 
    the measurement screen.   
        ・Read Free Running, Blow and Shut-off pressure values on the measurement screen. 
        ・Enter a midrange value between Free Running and Blow pressures in the “LEVER ON” 
    column on the “SET UP” screen. 
        ・Enter a midrange value between Blow and Shut-off pressures in the “SHUT-OFF” 
    column. 
        ・Check operating conditions on the measurement screen. 
     
      
    (2)In the case of TM Type Tool 
        ・Connect Tool in the first place. 
        ・Touch 
      key for more than 3 seconds and start “MENU” screen. 
    ・Set TOOL to TM TYPE on “SET UP” screen. 
        ・Then, select “SENSOR”. 
        ・Return to “MENU” screen by touching 
      key, and touch   key again to return to 
    the measurement screen. 
        ・Read Free Running and Blow pressure values on the measurement screen. 
        ・Enter a value not exceeding Free Running pressure in LEVER ON column on “SET UP” 
    screen. 
        ・Enter a midrange value between Free Running and Blow pressures in the “BLOW 
    START” column. 
        ・Check operating conditions on the measurement screen. 
     
     
    (3)In the case of Standard Tool 
        ・Connect Tool in the first place. 
        ・Touch 
      key for more than 3 seconds and start “MENU” screen. 
    ・Set TOOL to NON-SHUT TYPE on “SET UP” screen. 
        ・Then, select “SENSOR”. 
        ・Return to “MENU” screen by touching 
      key, and touch   key again to return to 
    the measurement screen. 
        ・Read Tool Stop, Free Running and Blow pressure values on the measurement screen. 
        ・Enter a midrange value between Tool Stop and Blow pressures in the “LEVER ON” 
    column on “SET UP” screen. 
        ・Enter a midrange value between Free Running and Blow pressures in the “BLOW 
    START” column. 
        ・Check operating conditions on the measurement screen.  
    						
    							AIMCO CORPORATE HEADQUARTERS 10000 SE Pine Street 
    Portland, Oregon  97216  
    Phone: (503) 254– 6600 
    Toll Free: 1 -800- 852-1368  
    AIM
    
    CO CHINA  
    Room 607, No. 3998 Hongxin Rd Dibao Plaza  
    Minhang District, Shanghai   
    China  
    Phone: 0086 -21- 34319246  
    Fax: 0086- 21-34319245
      LIT-MA
    N720      Rev. 03/2016  
    Printed in USA  ©2016 AIMCO AIMCO C
    ORPORATION D E
     MEXICO S A DE CV 
    Ave. C ristobal C olon 14529 
    Chihuahua, C hihuahua.  31125 
    Mexico 
    P
    hone: ( 01-614) 380- 1010 
    Fax: (01 -614) 380- 1019 
    AIMCO S PAIN 
    Avenida R ío Gallo, 4 31 
    19174 Galápagos - Guadalajara 
    Spain 
    P
    hone: + 34 673 34 99 25  
    						
    All Aimco Brakes manuals Comments (0)

    Related Manuals for Aimco Brakes Monitor UTM1500 Fastening Counter Manual