Aimco Brakes Monitor UTM1500 Fastening Counter Manual
Have a look at the manual Aimco Brakes Monitor UTM1500 Fastening Counter Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 85 Aimco Brakes manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
31 MEMORY WORK Make a choice among 1, 2, 3, 4, and ALL alternatives by using keys and specify WORK No. to call up on DISPLAY column. When ALL is selected, data pertaining to WORK 1~4 will be displayed altogether. Numbers to be shown in ( ) indicate data number. DISPLAY Select any of the items to call up. DATA :Numeric data in memory will be displayed. ANALSIS :Mean values and/or sigma values will be displayed. ・When is pressed down, the particulars of the item selected at DISPLAY column according to the Work No. selected at WORK column will be displayed. ERASE Make a choice among 1, 2, 3, 4, and ALL (1~4 all inclusive) by using keys and specify WORK No. of which memory data you intend to erase. When is pressed, memory data corresponding to the selected WORK No. will be erased. BAUD RATE(transmission speed) Set data transmission speed matching PC you will use. Initial Value : 38400 [bps] Setting Values : 19200, 38400, 57600, 115200 * * * MEMORY * * * ■WORK : 1(125) DISPLAY : DATA ERASE : 1 * * BAUD RATE * * BAUD RATE : 38400bps
32 Tool management(tool management) This function is specifically designed to notify operators of Tool maintenance timing, and when the preset Cycle Count or Cumulative Count has been attained, the timing will be notified through the means of LCD display, Buzzer and Terminal Block output. Cycle Count : Current total fastening number of Tool now in use. “CYC. COUNT” will be indicated on LCD display. Cumulative Count : Current total pulse number of Tool now in use. “PULS. NOS.” will be indicated on LCD display. (1)TOOL Make entries necessary to specify Tool; including Tool No. and Model. How to make entries ・Put the cursor on any alphanumeric, space, “-”and “.”character arranged on the 3 rd and 4th lines by moving the arrow key and press key. Then the character you selected will be put on the cursor position on the TOOL column on the 2 nd line. ・To erase the last character of TOOL column, touch RESET key. ・To return to Tool Management MENU screen, press key while putting the cursor on END. ・Up to 15 characters can be entered. (2)OUT SET Enter Cycle Count and Cumulative Pulse Number intended for maintenance works. CYC.COUNT1 : Cycle Count 1 CYC.COUNT2 : Cycle Count 2 Setting Range : 0~999999 You must make setting CYC. COUNT1
33 PULS.NOS.1 : Cumulative Pulse 1 PULS.NOS.2 : Cumulative Pulse 2 Setting Range : 0~9999999 pulses You must make setting PULS. NOS. 1
34 (3)CUMULATIVE COUNT Current Cycle Count and Cumulative Pulse Number Display and Clear: CYC.COUNT : Current cycle count PULS.NOS. : Current cumulative pulse number CLEAR : Cycle count and cumulative pulse number clearing ・Selecting CLEAR will call up the following window. ・Selecting YES will clear the current cycle count and cumulative pulse number and then call back CUMULATIVE COUNT screen. ・Selecting NO will call back CUMULATIVE COUNT screen without clearing the numbers. * CUMULATIVE COUNT * ■CYC.COUNT : 30000 PULS.NOS. : 200000 CLEAR ERASE COUNT DATA CONFIRM AND GO ON! ■NO YES
35 Pressure Value Setting Pressure value setting without using Automatic Setting Function (1)In the case of Shut-off Tool (TM) ・Connect Tool in the first place ・Touch key for more than 3 seconds and start “MENU” screen. ・Set TOOL to SHUT-OFF TYPE on “SET UP” screen. ・Then, select “SENSOR”. Select “NO DISPLAY” when a private pressure sensor will be used and select “DISPLAY” when a digital pressure sensor will be used. ・Return to “MENU” screen by touching key, and touch key again to return to the measurement screen. ・Read Free Running, Blow and Shut-off pressure values on the measurement screen. ・Enter a midrange value between Free Running and Blow pressures in the “LEVER ON” column on the “SET UP” screen. ・Enter a midrange value between Blow and Shut-off pressures in the “SHUT-OFF” column. ・Check operating conditions on the measurement screen. (2)In the case of TM Type Tool ・Connect Tool in the first place. ・Touch key for more than 3 seconds and start “MENU” screen. ・Set TOOL to TM TYPE on “SET UP” screen. ・Then, select “SENSOR”. ・Return to “MENU” screen by touching key, and touch key again to return to the measurement screen. ・Read Free Running and Blow pressure values on the measurement screen. ・Enter a value not exceeding Free Running pressure in LEVER ON column on “SET UP” screen. ・Enter a midrange value between Free Running and Blow pressures in the “BLOW START” column. ・Check operating conditions on the measurement screen. (3)In the case of Standard Tool ・Connect Tool in the first place. ・Touch key for more than 3 seconds and start “MENU” screen. ・Set TOOL to NON-SHUT TYPE on “SET UP” screen. ・Then, select “SENSOR”. ・Return to “MENU” screen by touching key, and touch key again to return to the measurement screen. ・Read Tool Stop, Free Running and Blow pressure values on the measurement screen. ・Enter a midrange value between Tool Stop and Blow pressures in the “LEVER ON” column on “SET UP” screen. ・Enter a midrange value between Free Running and Blow pressures in the “BLOW START” column. ・Check operating conditions on the measurement screen.
AIMCO CORPORATE HEADQUARTERS 10000 SE Pine Street Portland, Oregon 97216 Phone: (503) 254– 6600 Toll Free: 1 -800- 852-1368 AIM CO CHINA Room 607, No. 3998 Hongxin Rd Dibao Plaza Minhang District, Shanghai China Phone: 0086 -21- 34319246 Fax: 0086- 21-34319245 LIT-MA N720 Rev. 03/2016 Printed in USA ©2016 AIMCO AIMCO C ORPORATION D E MEXICO S A DE CV Ave. C ristobal C olon 14529 Chihuahua, C hihuahua. 31125 Mexico P hone: ( 01-614) 380- 1010 Fax: (01 -614) 380- 1019 AIMCO S PAIN Avenida R ío Gallo, 4 31 19174 Galápagos - Guadalajara Spain P hone: + 34 673 34 99 25