Aimco Brakes Monitor UTM1500 Fastening Counter Manual
Here you can view all the pages of manual Aimco Brakes Monitor UTM1500 Fastening Counter Manual. The Aimco Brakes manuals for Monitors are available online for free. You can easily download all the documents as PDF.
Page 11
11 Exterior Features (1)Front Side ①Power Switch |:ON ○:OFF ②Power Lamp(green) The green LED lamp lights up when the power switch is turned ON. ③Buzzer The volume of fastening recognition, NOK and Key Operation sound can be adjusted each independently. Low-tone buzzer can also be used alternatively. (Always use the low-tone buzzer at the maximum 5 volume setting as the buzzer does not produce audible sound with low settings.) Part Name:...
Page 12
12 ⑤2-digit, 7-segment LED Display Remaining fastening number will be indicated. (”WORK No.” will be indicated if “on a WORK No. basis setting” has been specified on MENU screen.) ⑥LCD (20-digit x 4 lines) Display 【During measurement】 First Line : Selected WORK No. Second Line : P1, P2 monitor indication. Blow start, shut-off detecting status will be indicated. ○ means “detecting” and ● means “not detecting”. TOOL TYPESHUT-OFF (ULT or other shut-off tools) TM (TM...
Page 13
13 (2)Back Side ①Terminal Block(detachable) Wiring to Input Terminal must be under no-voltage conditions. Wiring to Output Terminal must be less than DC24V. Always use Y-shape or round crimp-style terminals when wiring. ②Sensor Cable coupling connector (Pressure Sensor can be installed with the connector removed.) ③ANALOG OUT Analog signals will be output from Pressure Sensor. ④PC Connector Hook up the cable from PC. ⑤Power cable connector ⑥Fuse (spare...
Page 14
14 Functions Self-Diagnosis Function Self-diagnosis function will run in the main system at power-on. Software version will be displayed on the second line of LCD display during self-diagnosis. Memory Function Up to 1,500 fastening data can be saved. Zero Adjustment There are cases where sensor output voltage shows a bit different voltage from 0V even though the pressure sensor is under free of pressure conditions. To rectify such deviation, output voltage under no pressure...
Page 15
15 Settings Self-diagnosis function will run at power-on. Operation Mode will start when no faulty condition has been detected during the course of Self-diagnosis. Pressing for more than 3 seconds under Operation Mode will start MENU screen and then Program Mode will be initiated. You may change setting values under Program Mode. Note that Program Mode will render TM Tool or Standard Tool uncontrollable. Consequently, Valve Output will turn into ON status and you may not use...
Page 16
16 SET UP Function Setting TOOL(Tool Selection) Initial Setting:SHUT-OFF TYPE Select any among three selectable tools; SHUT-OFF TYPE/TM TYPE/NON- SHUT TYPE ・This selection is common among WORK №1~4. SHUT-OFF TYPE(Shut-off Tool) ・Tool will stop operation automatically upon completing bolt fastening operation, and then TM Signal will be output. ・When SHUT-OFF TYPE is selected, ON (Valve ON Timer) and OFF (Valve OFF Timer) initial values will become “0”...
Page 17
17 BLOW START/LEVER ON [Mpa](Blow Start Pressure/ Fastening Start Pressure) ・Measurement Start Pressure Initial Value Shut-off Tool : 0.10 TM Type Tool : 0.10 Standard Tool : 0.50 Setting Range 0.00~1.00 ・When using Shut-off Tool, the corresponding name will be BLOW START, and set a pressure value to effect Tool blow detection. ・When using TM Tool (not Shut-off) or Standard Tool, the corresponding name will be LEVER ON, and set a pressure value to effect Tool...
Page 18
18 UPPER PULSE No. (Upper Pulse Number) Setting Range : 0~999 Initial Value : 0 ・This is the upper limit for pulse number judgment. When the pulse number measured stepped across the preset number, Pulse HIGH NOK will result. ・This setting is common among WORK No. 1~4. ・In the case of 0 setting, pulse number upper limit judgment will not be performed. Reaction in the case of Pulse HIGH NOK detection: ・LCD Display : [Pulse High Error] ・Buzzer : ON ・Output Terminal : FAS. NOK will be...
Page 19
19 L. CONTR. (Fastening Number Count Operation Mode Selections) Initial Setting : LS1 ・Select Line Control Mode to be used during Fastening Number Count. ・This setting is common among WORK No. 1~4. ・Note that QL Terminal accepts inputs outside the operating range particularly specified using this function. LS1 ・All-the-time fastening number counting down ready condition will be rendered, and judgment will be made on Limit Switch input. COUNT OK judgment will be given when the preset...
Page 20
20 LS1・LS2 ・Fastening operation range will be defined. Operation will start (counting down ready condition) on LS1 input. ・When the preset fastening number is attained before LS2 input, fastening operation will finish. ・COUNT NOK judgment will be given when the preset fastening number is not attained at the time of LS2 input, and in this case, fastening operation will finish when COUNT OK condition resulted through NG handling operation. LS1・LS3・LS2...