Home > Aimco Brakes > Monitors > Aimco Brakes Monitor UECD4800 Instruction Manual

Aimco Brakes Monitor UECD4800 Instruction Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Aimco Brakes Monitor UECD4800 Instruction Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 85 Aimco Brakes manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 70  
    CS sensor: CS stands for Commutation Sensor.    This sensor is necessary to rotate the UEP tool 
    motor.
     
     
      
    						
    							 71
     
    17.2. Recommended Action 
     
    Error  Countermeasure 
    ZERO error 
    CAL error ・Check the connection between a tool and sensor cable.    Or, replace 
    them.   
    ・Check if the tool is running during the checking is being made. 
    Buffer Full error ・Set the setting of waveform memory function select to 1 or 4.  
    Setting error ・Check and correct the mode settings parameters.    Make sure that they 
    are logically correct like the formula START
    						
    							 72
    greater than necessary.  Select the AC reactor good for each UEPD 
    capacity. 
    Restart Prevention ・Clear this error after you confirm the safety.    The tool starts running 
    when the tool run signal is on.    Also, the insufficient amount of power 
    may cause this feature to be triggered.    Be sure to supply the UECD 
    with the proper amount of power.     
    Excessive Load 
     (Thermal) ・Remove the excessive load, change the bolt / nut fastening pattern, and 
    / or use the one size up UECD system.     
    Sensor Error ・Refer to the Trouble Shooting for more information.     
    CPU Error ・Check that there is no external noise effect on CPU. 
    Input Signal Error ・Refer to the Trouble Shooting for more information. 
     
    *1: Check the tightening time from start torque to cut, number of pulses, and angle per application 
    to make the appropriate settings.     
     
      
    						
    							 73
    18. Troubleshooting 
     
    Phenomenon Probable Cause Recommended Action 
    Driver unit 
    Not Powered ・ Not plugged in 
    ・ Switched off 
    ・ Main power voltage drop 
    ・ Incorrect size of UECD 
    connected to UEP tool 
    ・ Short-circuited  
    ・ Blown fuse ●Plug the UECD in. 
    ●Switch on the UECD.   
    ●Make the correct connection.     
    ●Repair or replace the UECD.     
    Driver Unit Error ・ The inherent intelligence of 
    UEP system works.   ●Check the error status on the 
    DRIVER DATA screen and switch 
    it on after correcting the problem. 
    Sensor error E-C.S. detected 
    * ・ UECD unconnected to UEP 
    tool 
    ・ Broken wire ●Confirm the cable connection. 
    ●Repair or replace the UECD. 
    Tool 
    UEP will not run. ・ Not plugged in 
    ・ Cable misconnection 
    ・ Broken wire 
    ・ Driver unit error 
    ・ Overworking the UEP tool ●Switch on the UEP system. 
    ●Make the correct connection. 
    ●Repair or replace the UEP. 
    ●Remove the excessive load. 
    UEP runs in a reverse 
    direction. ・ Reverse lever energized in 
    error ●Check the reverse lever position.   
    UEP will not run correctly. ・ Broken wire 
    ・ Driver error 
    ・ Mode settings incorrectly 
    made – i.e. fastening control 
    method ●Repair or replace the UEP. 
    ●See Chapter 17.2 Recommended 
    Action.   
    ●Work on the correct settings.         
    Error message E.SIG 
    displayed in operation* ・ Reverse lever energized in 
    error ●Switch it on again.     
    No tool power 
    ・ Oil leakage ●Repair or replace the UEP. 
    Heat generated 
    ・ Overworking the UEP tool ●Remove the excessive load. 
    Not torque controlled ・ Set the MODE 4 of DRIVER 
    DATA to 2.   
    ・ Set the Control Method of 
    MODE settings to 3.     ●Confirm the settings.     
    UEP-MC tool pulsing longer 
    than it should till it shuts off ・ Rise in heat inside UEP-MC 
    ・ Oil leakage ●Remove the excessive load. 
    ●Cool down the tool.     
    ●Repair or replace the UEP-MC. 
     
     
      
    						
    							  Corporate Headquarters 
    10000 SE Pine Street Ave. Cristóbal Colon 14529 
    Portland, OR  97216  Chihuahua, Chihuahua.  31125 
    800-852-1368 Mexico
    FAX 800-582-9015 011-52-(614) 380-1010
    www.aimco-global.com FAX 011-52-(614) 380-1019
     LIT-MANUECD     Rev. 
    4/2016 
    Printed in USA  ©2016 AIMCO  
    						
    All Aimco Brakes manuals Comments (0)

    Related Manuals for Aimco Brakes Monitor UECD4800 Instruction Manual