Home > Aimco Brakes > Monitors > Aimco Brakes Monitor UECD4800 Instruction Manual

Aimco Brakes Monitor UECD4800 Instruction Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Aimco Brakes Monitor UECD4800 Instruction Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 85 Aimco Brakes manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 50
    Setting of output terminals 
     
    Set up the signal allocations of output terminals by OUT TERMINAL 1 – OUT TERMINAL 5. 
     
    Default and name of terminal 
    Setup item Default (function) Name of terminal 
    OUT TERMINAL 1  1    (COUNT OK)  COUNT OK 
    OUT TERMINAL 2  2    (COUNT NOK)  COUNT NOK 
    OUT TERMINAL 3  3    (TORQUE OK)  TORQUE OK 
    OUT TERMINAL 4  4    (TORQUE NOK)  TORQUE NOK 
    OUT TERMINAL 5  5  (SV)  SV 
     
    Setup item 
     
    Setting Signal Function 
    1 COUNT OK Count OK signal   
    Signal output duration time is set by COUNT OK of TIMER 
    SETTING.  
    The UECD controller stops sending this signal when it 
    receives the RESET or LS signal even while COUNT OK is 
    being sent.   
    2 COUNT NOK Count NOK signal  
    Provide COUNT NOK signal output until COUNT NOK is 
    cleared.  
    3 TORQUE OK Torque OK signal 
    Signal output duration time is set by FASTENING OK of 
    TIMER SETTING.   
    The UECD controller stops sending this signal when the next 
    operation starts even while TORQUE OK is being sent.     
    4 TORQUE NOK Torque NOK signal   
    Provide TORQUE NOK signal output until TORQUE NOK is 
    cleared.  
    5 SV Provide the signal output when torque reaches the start 
    torque.  
    6 TORQUE LOW NOK Provide the signal output when the torque low NOK judgment 
    is provided.   
    7 TORQUE HIGH NOK Provide the signal output when the torque high NOK 
    judgment is provided.   
    8 OPERATION RANGE Provide the signal output while the fastening is in process. 
    9 CPU RUN Provide the signal output when UECD is in operation. 
    Switch off when UECD gets inoperable status while the 
    setting is overwritten.   
    10 CAUTION Caution signal   
    Provide this signal output when the cumulative fastening 
    number or pulse blow number reaches the preset repair 
    fastener number or pulse blow number. 
    11  WORK A ANSWER 
    12 WORK B ANSWER 
    13 WORK C ANSWER WORK Answer 
    Provide answer output signal of active work No. 
    14 WK 1 COUNT OK 
    15 WK 2 COUNT OK 
    16 WK 3 COUNT OK 
    17 WK 4 COUNT OK 
    18 WK 5 COUNT OK COUNT OK per WORK NO. 
     
    Note : It is not possible to assign same signal to two or more terminals.
     
     
      
    						
    							 51
    10.7. LAN (LAN setting) 
    This is to set up for the Ethernet connection.    
    Set up the values in LAN SETTING screen, and [
    ] is displayed.    After you changed the setting 
    values all, please do not press 
     until [] goes off.    It takes approx. 20 seconds. 
     
     
     
     
     
     
     
     
     
     
     
     
     
    IP ADDRESS 1 - 4 
    Default : 120.0.100.1 
    Setting range : 0 - 255 
    [Function] 
    This is to determine the IP address of UECD.    
     
     
    SUBNET MASK 
    Default : 0008 
    Setting range : 1 - 31 
    Setting:     1   (255.  255.  255. 254) 
    8 (255.  255.  255.  0) 
         16  (255.  255.  0.   0) 
         24  (255.  0.  0.   0) 
         31  (128.  0.  0.   0) 
    [Function] 
    This is to set up Subnet mask.   
     
     
    DEFAULT GATEWAY   
    Default :    0. 0. 0. 0. 
    Setting range : 0 – 255 
    [Function]  
    This is to set the default gateway. 
    Set up when connecting to PC via router.     
     
     
    TCP PORT 
    Default : 2101 
    Setting range : 0 – 9999 
    [Function]  
    This is to set up the TCP port of UECD.    
     
     
    LAN■#1■■■■■■■(6/7) 
    →Remote TCP Port ■■02101 
    ■LAN Retry Num.■■■■03 
    ■Comm.-less TIM■  ■■10 LAN■#1■■■■■■■(5/7)
    →Host IP Addr 2 ■■0000
    ■Host IP Addr 3 ■■0100
    ■Host IP Addr 4 ■■0000LAN■#1■■■■■■■(4/7) 
    →TCP Port■■■■■■02101 
    ■Connect Mode ■■■■0001 
    ■Host IP Addr 1   ■■0120
     
    LAN■#1■■■■■■■(3/7) 
    →Default Gatway    ■0000 
    ■Default Gatway    ■0000 
    ■Default Gatway    ■0000
     
    LAN■#1■■■■■■■(2/7)
    →IP Address 4■■■■■0001
    ■Subnet Mask■■ ■■■0008
    ■Default Gatway      ■0000LAN1■#1■■■■■■■(1/7) 
    →IP Address 1■■■■■0120
    ■IP Address 2■■■■■0000
    ■IP Address 3■■■■■0100
    LAN■#1■■■■■■■(7/7) 
    →MAC Address■■■■***** 
    ■■■■■■■■■■■■■
    ■■■■■■■  
    						
    							 52
    CONNECT MODE (Connection mode)   
    Default : 1 
    Setting : 0    Set UECD as host 
    Setting : 1    Set UECD as client   
    [Function] 
    Allocate [1] (UECD as client) to this function.    
     
     
    HOST IP ADDR 1 – 4 (HOST IP address) 
    Default : 120.0.100.0 
    Setting range : 0 - 255 
    [Function]  
    Enter the IP address of the PC which is used for the setup.   
     
     
    REMOTE TCP POR (Remote TCP port) 
    Default : 2101 
    [Function] 
    This is to set up TCP port of PC which communicates to UECD.     
    Set up with same value of TCP port of UECD.     
     
     
    LAN RETRY NUM. (LAN retry number)   
    Default : 3 
    Setting range : 0 - 10 
    This is to determine the retry number to be made. 
     
     
    Comm.-less time (LAN no responding limit time) 
    Default : 10 
    Setting range : 0 - 10 
    This is to determine the waiting time in case of no responding.   
     
     
    MAC ADDRESS   
    Default : Assign unique address   
    Setting range : 0 - 9999 
    Mac address of UECD.   
    Impossible to change the setting value. 
     
     
      
    						
    							 53
     
    10.8. Program Number Change 
     
    This is to set the program number choice.    Maximum 8 kinds (fastening torque, judgment values 
    of torque and angle etc.) of program can be set up within same work number by using the program 
    number change function.    It is possible to set up maximum 20 fasteners under same work number.   
    8 kinds of work number (from program 1 to 8) can be set up for first fastener up to 20th fastener.     
    Note:    This function is available in UECD-4800 version 1.15 and later version.   
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    PROGRAM NO SEL (Program number change select) 
    Default : 0 
    Setting : 0      Not use   
    Setting : 1      Use, and program number is selected by signal input from terminal of UECD.   
    Setting : 2      Select program number by the 32 byte data received on the serial port on the rear 
    panel.    Set 1 to ID DATA OUT, and set 32 to ID DATA NUMB in the DATA OUT 
    SETTING screen.   
    Setting : 3      Receive work number signal from 48 byte data received on the serial port on the rear 
    panel.    Set 1 to ID DATA OUT, and set 48 to ID DATA NUMB in the DATA OUT 
    SETTING screen.    
     
    【Function】 
    ・This is to determine whether use or not the program number choice, and how to change program 
    number.   
    ・When setting value is changed from 0 to any of 1 – 3 or vice versa, UECD clears memory data.   
    It is because UECD memorizes program number when program number choice is used.   
     
     
     
    PRGRAM NO SW (Program number change switch) 
    Default : 0 
    Setting : 0    Switch to next work number only when UECD provides fastening OK. 
    Setting : 1    Switch to next work number whichever UECD provides fastening OK/NOK.     
    Setting : 2    Switch to next work number when UECD provides OK or torque HIGH NOK.     
    【Function】 
    ・This is to determine the condition to have UECD switched to next work number when program 
    number choice is used.     
     
     
    PROGRAM■SEL■1■■(1/8) 
    →Program No SEL■■■■0 
    ■Program No SW■■■■1 
    ■First■■■■■■■■■0
     
    PROGRAM■SEL■1■■(2/8)
    →Second■■■■■■■■0
    ■Third■■■■■■■■■0
    ■Fourth   ■■■■■■■0PROGRAM■SEL■1■■(3/8) 
    →Fifth■■■■■■■■■0 
    ■Sixth■■■■■■■■■0 
    ■Seventh■■■■■■■■0
     
    PROGRAM■SEL■1■■(4/8) 
    →Eighth■■■■■■■■0 
    ■Ninth■■■■■■■■■0 
    ■10th■■■■■■■■■0
     
    PROGRAM■SEL■1■■(5/8)
    →11th■■■■■■■■■0
    ■12th■■■■■■■■■0
    ■13th■■■■■■■■■0PROGRAM■SEL■1■■(6/8) 
    →14th■■■■■■■■■0 
    ■15th■■■■■■■■■0 
    ■16th■■■■■■■■■0
     
    PROGRAM■SEL■1■■(7/8) 
    →17th■■■■■■■■■0 
    ■18th■■■■■■■■■0 
    ■19th■■■■■■■■■0
     
    PROGRAM■SEL■1■■(8/8)
    →20th■■■■■■■■0
    ■■■■■■■■■■■0
    ■■■■■■■■■■■0 
    						
    							 54
    FIRST – 20TH FASTENER 
    Default : 0 
    Setting range : 0 - 8 
    Setting : 0  Fastening is ended.   
          1 – 8 :    Fastening is performed per setting of selected work number.     
    【Function】 
    ・This is to determine which fastener is fastened by which setting of work number.    
     
     
    【Setting example】 
    Set either 1 or 2 to PRGRAM NO SEL, and set 1 to First, Second and Third fastener, and 2 to 
    Fourth fastener.    First, second and third fastener is fastened up to CUT values of WORK 1 setting, 
    and judged in accordance to WORK 1 setting.  Fourth fastener is fastened in accordance to 
    WORK 2 setting.    Set 0 to fifth fastener, if the fastening is ended with fourth fastener.     
    When either 1 or 2 is set to PROGRAM NO SEL, it is possible to fasten up to 20 fasteners.    It is 
    possible to set up work number to each fastener from first up to 20th.         
    Work number combination is settable with maximum 8 kinds from program 1 to 8.   
    When 3 is set to PROGRAM NO SEL, work number combination and fastening number are 
    decided and received from the serial port on the rear panel.  
     
     
     
     
     
     
     
     
     
     
     
    PROGRAM■SEL■  3■■■(4/8)
    →EIGHTH   ■■■■■■■■0
      NINTH■  ■    ■■■■■0
    ■10th   ■■■■■■■■■0
    Select the program number you want to set up 
    parameters.  Selectable from the program 
    number 1 up to 8.      
    						
    							 55
     
    10.9. MEMORY DATA 
     
    This is to set up the setting of memory data and the display or the clear of the calculated value 
    from the memory data.
     
     
     
     
     
     
    AVR (Average value) (former name: MODE 82) 
    Function 
    ・Displays average value of memorized data 
    Note: This is not a setting value.   
     
     
     
     
    x: Average 
    n: Number of Data Points 
     
     
    σ (σ value) (former name MODE 83) 
    Function 
    ・Displays σ value of memorized data 
    Note: This is not a setting value. 
     
     
     
     
     
    σ: Standard deviation 
     
     
    3σ+/- (3 σ value / Average value plus-minus % value / former name MODE 84)  
    Function 
    ・Displays the 3σ / Average value (deviation value) of the memorized data 
     
    3σ 
    _ 
    3σ value = 
    X x 100%
     
    3σ value : Rate of variability 
     
     
    MEMORY■DATA■■■■(1/3) 
    ■AVR.            ■■000.0 
    →
    ■   ■■■■■■■00.00 
    ■3
    +/-%          ■■00.00 
    MEMORY■DATA■■■■(2/3) 
    ■CP        ■■■■■00.00
    →CPK       ■■■■■00.00
    ■Memory Output ■■■■■0MEMORY■DATA■■■■(3/3) 
    ■Memory Block      ■■■0 
    ■MEM. Contents ■■■■■0 
    →Memory Clear■■■■■■0 
    nx ~ x x
    x
    n 2 1+ + +
    =
    ⎥
    ⎦ ⎤
    ⎢
    ⎣ ⎡
    =∑2
    n) x - (x
    1 n-1
    σ 
    						
    							 56
    CP (CP value / former name MODE 85) 
    Function   
    ・Displays CP value of memorized data 
    ・Displayed value is calculated one from the selected work number setting value (torque high and 
    low limit value) 
    Note: This is not a setting value. 
     
     
     
     
     
    CP = Process Capability Index 
     
     
    CPK (CPK value / former name MODE 86)  
    ・Displays CPK value of memorized data 
    ・Displayed value is the calculated one from the selected work number setting values (torque high 
    and low limit value).     
    Note : This is not a setting value.     
     
    B 
    CPK 
    = 
    3σ 
     
    B1 : Upper limit – Average   
    B2 : Average – Lower limit 
    B : Smaller value between B1 and B2 
    CPK : Process Capability Index (deviation of average inclusive) 
     
     
    MEMORY BLOCK (Memory data block / former name : MODE 87) 
    Default : 3 
    Setting  :  1  UECD stores data of work number all in one without time/date and ID number.   
    (Maximum 12,000 pcs.) 
    Setting  :  2  UECD stores data per work number without time/date nor ID number.         
    (Maximum 1,500 pcs.) 
    Setting  :  3  UECD stores data of work number all in one including time/date, but without ID 
    number.   (Maximum 5,400 pcs.)  
    Setting  :  4  UECD stores data per work number including time/date, but without ID number.   
    (Maximum 680 pcs.)   
    Setting  :  5  UECD stores data of work number all in one including time/date and ID number. 
    (Maximum 2,200 pcs.) 
    Setting  :  6  UECD stores data per work number including time/data and ID number. 
         (Maximum 270 pcs.) 
    【Function】 
    ・This is to determine whether per work number or work number 1 - 8 all in one, and whether 
    include time/data and ID number UECD stores the data.         
    ・When the data is stored per work number, the storable maximum data becomes 1/8 of the one 
    stored by batch.    UECD drops old data to memorize new data one by one after the data storage 
    comes to the maximum.     
    ・When the data is stored with time/date, the storable maximum data becomes approx. 1/2.     
    ・UECD calculates average value, CPK value etc. per block.    
     
    Upper limit –Lower limit
    CP = 
    6σ  
    						
    							 57
    MEM. CONTENTS (memory content / former name MODE 88) 
    Default : 0 
    Setting : 0      Not memorize the fastening data 
    Setting : 1      Memorize all fastening data 
    UECD provides warning by the buzzer and the warning display [COUP] when the 
    data storage comes to the last 10 pieces to maximum memory.    Switch on RESET 
    terminal or press the reset key, and the display will go off.    But UECD provides 
    warning with same way, if you continue fastening.     
    Setting : 2      Same as the setting 1, but not provide the warning of the maximum memory.   
    Setting : 3      Memorize only OK data and provide the warning of the maximum memory 
    Setting : 4      Same as the setting 3, but not provide the warning of the maximum memory 
    Function 
    ・This is to determine what to memorize and whether to warn the maximum memory when the data 
    storage comes to the last 10 pieces to maximum memory.     
    ・All memorized data is cleared when the setting value is changed.   
     
     
    MEMORY CLEAR (clear of the memorized data / former name MODE 89) 
    Function 
    ・When it is set to [1], UECD clears all the memorized data of the specified work number.     
    ・[-CLE] is displayed on the display and press 
     again to execute the data clear.     
    ・Same can be done through PC by pressing 
     in the statistic screen of the setup software.     
     
     
    UNUS. HIST. CL (clear the unusual history) 
    【Function】 
    ・Set to [1] to clear the history of the error or trouble like CAL error, ZERO error etc. (other than the 
    errors included in the fastening data) memorized in UECD-4800.    
     
     
     
     
      
    						
    							 58
     
    10.10. DRIVER DATA 
     
    The Driver Data screen allows you to program the rpm and acceleration time of the tool.    When it 
    fires any error related to driver, the UECD controller shows an error message on screen.    Please 
    correct the error.    
    Note 1: Be sure to make the appropriate driver settings.    The inappropriate settings may 
    cause a tool not to work.     
    Note 2: The programming setup software that comes with UECD controller will not allow 
    you to work on the driver settings.    
     
     
     
     
     
     
     
    (1) How to change the driver settings 
     
    1. Press 
     key once.    The mode number starts flushing up on screen.     
    2. Select the mode number that you desire to change with 
    &  keys and press  key. 
    3. Change the settings with 
    & keys.  
     
    4. Press 
     key to enter the changed settings into controller.   
     
    5. Repeat the above 1 – 4 procedures if there are more settings to be changed.    After all the 
    changes are made, press 
     key to go back to the measuring screen.     
     
     
    (2) Setup Items 
    MODE 00 (Full Speed RPM) 
    Default : 2,000 rpm 
    Recommended Setting Range :1,500 ~ 2,500 rpm 
    Programmable Setting Range : 0 ~ 3,000 rpm 
    【Function】 
    ・This is to determine how fast the UEP-MC tool runs in operation.     
     
     
    MODE 01 (Slow Speed RPM) 
    Default : 500 rpm 
    Recommended Setting Range :500 ~ 2,500 rpm 
    Programmable Setting Range : 0 ~ 3,000 rpm 
    【Function】 
    ・This is to determine how slowly UEP-MC tool runs in operation.     
     
     
    MODE 02 (Acceleration Time) 
    Default : 0.05 seconds 
    Programmable Setting Range : 0.00 ~ 3,600 rpm 
    【Function】 
    ・This is to determine how fast the UEP-MC tool reaches 1,000 rpm from 0 rpm.     
    WORK  NO.1 
     
    DATA    00000 
    MODE    00
     
    Controller Settings or Error Status 
    MODE number  
    						
    							 59
    MODE 03 (Slow Down Time) 
    Default : 0.05 seconds 
    Programmable Setting Range : 0.00 ~ 3,600 rpm 
    【Function】 
    ・This is to determine how fast the UEP-MC tool reaches 0 rpm from 1,000 rpm.     
     
     
    MODE 04 (Fastening Control Method) 
    Default : 2 
    Setting : 0      Timer Controlled Fastening 
    Setting : 1      Blow Number Controlled Fastening 
    Setting : 2      Torque Controlled Fastening 
    【Function】 
    ・This is to determine the control method of the tool.     
    Use the setting 2 only.     
     
     
    MODE 05 (Fastening Time Setting) (Not used now)
     
    Default : 0.5 seconds 
    Programmable Setting Range : 0.0 ~ 5.0 seconds 
    【Function】 
    ・Use this function when the MODE 04 is set to 0 only.    Never touch this function.     
     
     
    MODE 06 (Blow Number Setting) (Not used now)
     
    Default : 15 
    Programmable Setting Range : 0 ~ 100 blows 
    【Function】 
    ・Use this function when the MODE 04 is set to 1 only.    Never touch this function.     
     
     
    MODE 07 (OK Outputs Signal Timer) (Not used now)
     
    Default : 0.1 
    Programmable Setting Range : 0.1 ~ 0.3 seconds 
    【Function】 
    ・Never touch this function.     
     
     
    MODE 08 (Start Level Detection Value) (Not used now)
     
    Default : 60 
    Programmable Setting Range : 0 ~ 255 
    【Function】 
    ・This is to determine the value to detect the bolt/nut seating.    Use this function when the MODE 
    04 is set to 0 or 1.    Never touch this function.     
     
     
    MODE 09 (Overriding Method for NOK Tightening) (Not used now)
     
    Default : 0 
    Programmable Setting Range : 0, 1, & 2 
     
      
    						
    All Aimco Brakes manuals Comments (0)

    Related Manuals for Aimco Brakes Monitor UECD4800 Instruction Manual