Page 51

 50
Setting of output terminals 
 
Set up the signal allocations of output terminals by OUT TERMINAL 1 – OUT TERMINAL 5. 
 
Default and name of terminal 
Setup item Default (function) Name of terminal 
OUT TERMINAL 1  1    (COUNT OK)  COUNT OK 
OUT TERMINAL 2  2    (COUNT NOK)  COUNT NOK 
OUT TERMINAL 3  3    (TORQUE OK)  TORQUE OK 
OUT TERMINAL 4  4    (TORQUE NOK)  TORQUE NOK 
OUT TERMINAL 5  5  (SV)  SV 
 
Setup item 
 
Setting Signal Function 
1 COUNT OK Count OK signal   
Signal output duration time...

Page 52

 51
10.7. LAN (LAN setting) 
This is to set up for the Ethernet connection.    
Set up the values in LAN SETTING screen, and [
] is displayed.    After you changed the setting 
values all, please do not press 
 until [] goes off.    It takes approx. 20 seconds. 
 
 
 
 
 
 
 
 
 
 
 
 
 
IP ADDRESS 1 - 4 
Default : 120.0.100.1 
Setting range : 0 - 255 
[Function] 
This is to determine the IP address of UECD.    
 
 
SUBNET MASK 
Default : 0008 
Setting range : 1 - 31 
Setting:     1   (255.  255.  255....

Page 53

 52
CONNECT MODE (Connection mode)   
Default : 1 
Setting : 0    Set UECD as host 
Setting : 1    Set UECD as client   
[Function] 
Allocate [1] (UECD as client) to this function.    
 
 
HOST IP ADDR 1 – 4 (HOST IP address) 
Default : 120.0.100.0 
Setting range : 0 - 255 
[Function]  
Enter the IP address of the PC which is used for the setup.   
 
 
REMOTE TCP POR (Remote TCP port) 
Default : 2101 
[Function] 
This is to set up TCP port of PC which communicates to UECD.     
Set up with same value of...

Page 54

 53
 
10.8. Program Number Change 
 
This is to set the program number choice.    Maximum 8 kinds (fastening torque, judgment values 
of torque and angle etc.) of program can be set up within same work number by using the program 
number change function.    It is possible to set up maximum 20 fasteners under same work number.   
8 kinds of work number (from program 1 to 8) can be set up for first fastener up to 20th fastener.     
Note:    This function is available in UECD-4800 version 1.15 and later...

Page 55

 54
FIRST – 20TH FASTENER 
Default : 0 
Setting range : 0 - 8 
Setting : 0  Fastening is ended.   
      1 – 8 :    Fastening is performed per setting of selected work number.     
【Function】 
・This is to determine which fastener is fastened by which setting of work number.    
 
 
【Setting example】 
Set either 1 or 2 to PRGRAM NO SEL, and set 1 to First, Second and Third fastener, and 2 to 
Fourth fastener.    First, second and third fastener is fastened up to CUT values of WORK 1 setting, 
and judged...

Page 56

 55
 
10.9. MEMORY DATA 
 
This is to set up the setting of memory data and the display or the clear of the calculated value 
from the memory data.
 
 
 
 
 
 
AVR (Average value) (former name: MODE 82) 
Function 
・Displays average value of memorized data 
Note: This is not a setting value.   
 
 
 
 
x: Average 
n: Number of Data Points 
 
 
σ (σ value) (former name MODE 83) 
Function 
・Displays σ value of memorized data 
Note: This is not a setting value. 
 
 
 
 
 
σ: Standard deviation 
 
 
3σ+/- (3...

Page 57

 56
CP (CP value / former name MODE 85) 
Function   
・Displays CP value of memorized data 
・Displayed value is calculated one from the selected work number setting value (torque high and 
low limit value) 
Note: This is not a setting value. 
 
 
 
 
 
CP = Process Capability Index 
 
 
CPK (CPK value / former name MODE 86)  
・Displays CPK value of memorized data 
・Displayed value is the calculated one from the selected work number setting values (torque high 
and low limit value).     
Note : This is not...

Page 58

 57
MEM. CONTENTS (memory content / former name MODE 88) 
Default : 0 
Setting : 0      Not memorize the fastening data 
Setting : 1      Memorize all fastening data 
UECD provides warning by the buzzer and the warning display [COUP] when the 
data storage comes to the last 10 pieces to maximum memory.    Switch on RESET 
terminal or press the reset key, and the display will go off.    But UECD provides 
warning with same way, if you continue fastening.     
Setting : 2      Same as the setting 1, but...

Page 59

 58
 
10.10. DRIVER DATA 
 
The Driver Data screen allows you to program the rpm and acceleration time of the tool.    When it 
fires any error related to driver, the UECD controller shows an error message on screen.    Please 
correct the error.    
Note 1: Be sure to make the appropriate driver settings.    The inappropriate settings may 
cause a tool not to work.     
Note 2: The programming setup software that comes with UECD controller will not allow 
you to work on the driver settings....

Page 60

 59
MODE 03 (Slow Down Time) 
Default : 0.05 seconds 
Programmable Setting Range : 0.00 ~ 3,600 rpm 
【Function】 
・This is to determine how fast the UEP-MC tool reaches 0 rpm from 1,000 rpm.     
 
 
MODE 04 (Fastening Control Method) 
Default : 2 
Setting : 0      Timer Controlled Fastening 
Setting : 1      Blow Number Controlled Fastening 
Setting : 2      Torque Controlled Fastening 
【Function】 
・This is to determine the control method of the tool.     
Use the setting 2 only.     
 
 
MODE 05...