50 Setting of output terminals Set up the signal allocations of output terminals by OUT TERMINAL 1 – OUT TERMINAL 5. Default and name of terminal Setup item Default (function) Name of terminal OUT TERMINAL 1 1 (COUNT OK) COUNT OK OUT TERMINAL 2 2 (COUNT NOK) COUNT NOK OUT TERMINAL 3 3 (TORQUE OK) TORQUE OK OUT TERMINAL 4 4 (TORQUE NOK) TORQUE NOK OUT TERMINAL 5 5 (SV) SV Setup item Setting Signal Function 1 COUNT OK Count OK signal Signal output duration time...
Page 52
51 10.7. LAN (LAN setting) This is to set up for the Ethernet connection. Set up the values in LAN SETTING screen, and [ ] is displayed. After you changed the setting values all, please do not press until [] goes off. It takes approx. 20 seconds. IP ADDRESS 1 - 4 Default : 120.0.100.1 Setting range : 0 - 255 [Function] This is to determine the IP address of UECD. SUBNET MASK Default : 0008 Setting range : 1 - 31 Setting: 1 (255. 255. 255....
Page 53
52 CONNECT MODE (Connection mode) Default : 1 Setting : 0 Set UECD as host Setting : 1 Set UECD as client [Function] Allocate [1] (UECD as client) to this function. HOST IP ADDR 1 – 4 (HOST IP address) Default : 120.0.100.0 Setting range : 0 - 255 [Function] Enter the IP address of the PC which is used for the setup. REMOTE TCP POR (Remote TCP port) Default : 2101 [Function] This is to set up TCP port of PC which communicates to UECD. Set up with same value of...
Page 54
53 10.8. Program Number Change This is to set the program number choice. Maximum 8 kinds (fastening torque, judgment values of torque and angle etc.) of program can be set up within same work number by using the program number change function. It is possible to set up maximum 20 fasteners under same work number. 8 kinds of work number (from program 1 to 8) can be set up for first fastener up to 20th fastener. Note: This function is available in UECD-4800 version 1.15 and later...
Page 55
54 FIRST – 20TH FASTENER Default : 0 Setting range : 0 - 8 Setting : 0 Fastening is ended. 1 – 8 : Fastening is performed per setting of selected work number. 【Function】 ・This is to determine which fastener is fastened by which setting of work number. 【Setting example】 Set either 1 or 2 to PRGRAM NO SEL, and set 1 to First, Second and Third fastener, and 2 to Fourth fastener. First, second and third fastener is fastened up to CUT values of WORK 1 setting, and judged...
Page 56
55 10.9. MEMORY DATA This is to set up the setting of memory data and the display or the clear of the calculated value from the memory data. AVR (Average value) (former name: MODE 82) Function ・Displays average value of memorized data Note: This is not a setting value. x: Average n: Number of Data Points σ (σ value) (former name MODE 83) Function ・Displays σ value of memorized data Note: This is not a setting value. σ: Standard deviation 3σ+/- (3...
Page 57
56 CP (CP value / former name MODE 85) Function ・Displays CP value of memorized data ・Displayed value is calculated one from the selected work number setting value (torque high and low limit value) Note: This is not a setting value. CP = Process Capability Index CPK (CPK value / former name MODE 86) ・Displays CPK value of memorized data ・Displayed value is the calculated one from the selected work number setting values (torque high and low limit value). Note : This is not...
Page 58
57 MEM. CONTENTS (memory content / former name MODE 88) Default : 0 Setting : 0 Not memorize the fastening data Setting : 1 Memorize all fastening data UECD provides warning by the buzzer and the warning display [COUP] when the data storage comes to the last 10 pieces to maximum memory. Switch on RESET terminal or press the reset key, and the display will go off. But UECD provides warning with same way, if you continue fastening. Setting : 2 Same as the setting 1, but...
Page 59
58 10.10. DRIVER DATA The Driver Data screen allows you to program the rpm and acceleration time of the tool. When it fires any error related to driver, the UECD controller shows an error message on screen. Please correct the error. Note 1: Be sure to make the appropriate driver settings. The inappropriate settings may cause a tool not to work. Note 2: The programming setup software that comes with UECD controller will not allow you to work on the driver settings....
Page 60
59 MODE 03 (Slow Down Time) Default : 0.05 seconds Programmable Setting Range : 0.00 ~ 3,600 rpm 【Function】 ・This is to determine how fast the UEP-MC tool reaches 0 rpm from 1,000 rpm. MODE 04 (Fastening Control Method) Default : 2 Setting : 0 Timer Controlled Fastening Setting : 1 Blow Number Controlled Fastening Setting : 2 Torque Controlled Fastening 【Function】 ・This is to determine the control method of the tool. Use the setting 2 only. MODE 05...