Home > Aimco Brakes > Monitors > Aimco Brakes Monitor UECD4800 Instruction Manual

Aimco Brakes Monitor UECD4800 Instruction Manual

Here you can view all the pages of manual Aimco Brakes Monitor UECD4800 Instruction Manual. The Aimco Brakes manuals for Monitors are available online for free. You can easily download all the documents as PDF.

Page 41

 40
FASTENING OK (Fastening OK signal output timer / former name : TIMER 4) 
Default : 9999 
Setting range : 0 – 9999 [msec]   
【Function】 
・This is to determine the fastening OK signal output duration time from output terminal TORQUE 
OK.    Not necessary to set up this timer usually.     
・Set up this timer only when duration of output signal affects external PLC or circuit. 
・Set 0, and UECD maintains signal output until next cycle starts.    
・UECD stops firing Torque OK signal when the next...

Page 42

 41
VALVE RETURN (Valve return timer / former name : TIMER 20) 
Default : 300 
Setting range : 1 – 9999 [msec] 
【Function】 
・
This timer starts functioning when the judgment delay timer comes up, and UECD switch off the 
valve (valve on) when this timer comes up. 
 
 
 
REVERSE ROTATION (Reverse rotation complete delay timer / former name : TIMER 21) (Not 
used now) 
Default : 300   
Setting range : 0 – 9999 [msec] 
【Function】 
・Use this timer when 9 is set to TIGHTENING MODE. 
  
Not used now 
 
 
PIN...

Page 43

 42
YEAR  
Default : 0 
Setting range : 0 – 99 [Year] 
【Function】 
・This is to set the year of calendar timer of UECD.     
・Enter 0, and the year of calendar timer is set to [Year 2000].    Enter 6, and the year of calendar 
time is set to [Year2006]. 
  
 
 
MONTH 
Default : 0 
Setting range : 1 – 12 [Month] 
【Function】 
・This is to set the month of calendar timer of UECD. 
 
 
DAY 
Default : 0 
Setting range : 1 – 31 [Day] 
【Function】 
・This is to set the day of calendar timer of UECD.
 
 
 
HOUR...

Page 44

 43
 
10.4. Data output setting 
Determine the contents of the output data and memory data sent through the serial port of the rear 
panel of UECD controller.    
 
 
 
 
 
 
 
 
 
UEC NO. (former name : MODE 98) 
Default : 1 
Setting : 1 – 25     
【Function】 
Give every UECD its own number when plural UECDs are in use connected to PC by RS232C.    
 
 
OUT. MOVEMENT (former name : MODE 58) 
Default : 0 
Setting : 0 Output all data through RS232C 
Setting : 1    Output only the following errors through...

Page 45

 44
BIT (Bit length select for the RS232C output / former name : MODE 61) 
Default : 1 
Setting : 0    7 bit 
Setting : 1    8 bit 
【Function】 
This is to determine the bit length of output data sent through data output RS232C port.   
 
 
STOP (Stop bit select for the RS232C output / former name : MODE 62) 
Default : 0 
Setting : 0    1 bit 
Setting : 1    2 bit 
【Function】 
This is to determine the stop bit of output data sent through data output RS232C port.   
 
 
PARITY (Parity bit select for the...

Page 46

 45
DECISION (Fastening judgment output select / former name : MODE 69) 
Default : 1 
Setting : 0    Not output 
Setting : 1    Output 
【Function】 
This is to determine whether include or not the judgment in output data sent through data output 
RS232C port. 
 
Contents ASCII code HEX code 
TORQUE OK  @  40H 
START LEVEL ERROR  C  43H 
CYCLE ERROR  D  44H 
INITIAL ERROR  E  45H 
CYCLE OVER ERROR  F  46H 
INCOMPLETE JOB ERROR  G  47H 
TORQUE LOW NOKK  H  48H 
TORQUE HIGH NOK  I  49H 
PULSE LOW NOK  L  4CH...

Page 47

 46
ID DATA SLCT (ID data output select)  
Default : 0 
Setting : 0      Not output 
Setting : 1      Output 
【Function】 
This is to determine whether include or not ID number in output data sent through data output 
RS232C port.   
 
 
ID DATA NUMB. (ID data digit number)   
Default : 0 
Setting range : 1 - 48 
【Function】 
This is to determine the digit number of VIN NO.   
The digit that is not used should be filled with [0].     
 
 
 
  

Page 48

 47
 
10.5. Tool Control 
 
UECD can memorize the total fastening number and pulse number since a tool is brought into use.   
It enables UECD to provide a notice of simple maintenance such as oil change by [WARNING 
COUNT/PULSE] and parts replacement/overhaul by [REPAIR COUNT/PULSE].   
 
 
 
 
 
 
 
TIGHTENING COUNT (Total tightening count number [1 unit : 10,000 fasteners]) 
Default : 0 
Setting range : 0 – 99999 [1 unit : 10,000 fasteners] 
・This is total fastening number of the tool now in use since...

Page 49

 48
WARNING PULSE (Warning pulse blow number [1 unit : 10,000 pulses]) 
Default : 00 
Setting range : 0 – 9998 [1 unit : 10,000 pulses] 
・UECD displays a warning message when the total pulse blow number reaches preset pulses.   
・Set the number of pulse blow that you are going to repair like oil change a tool next time.     
【Display status when number of pulse blow reaches warning pulse】 
・Buzzer sounds. Press 
 to stop.     
・7 segment displays [kcP.E.] 
Note: Set [0] when not use. 
 
 
REPAIR COUNT...

Page 50

 49
 
10.6. IN/OUT PUT (Setting of signal allocations of input/output terminal board) 
Signal allocations of input and output terminal board is free format.  You can change signal 
allocations as required by setting.   
 
 
 
 
 
 
 
 
 
 
 
 
Setting of input terminals  
 
Set the signal allocations of input terminals by IN TERMINAL 1 to IN TERMINAL 5. 
 
Default and name of terminal
 
 
   Setup item Default (function) Name of terminal 
IN TERMINAL 1  1  (LS1)  LS1 
IN TERMINAL 2  2  (START)  START 
IN...
Start reading Aimco Brakes Monitor UECD4800 Instruction Manual

Related Manuals for Aimco Brakes Monitor UECD4800 Instruction Manual

All Aimco Brakes manuals