40 FASTENING OK (Fastening OK signal output timer / former name : TIMER 4) Default : 9999 Setting range : 0 – 9999 [msec] 【Function】 ・This is to determine the fastening OK signal output duration time from output terminal TORQUE OK. Not necessary to set up this timer usually. ・Set up this timer only when duration of output signal affects external PLC or circuit. ・Set 0, and UECD maintains signal output until next cycle starts. ・UECD stops firing Torque OK signal when the next...
Page 42
41 VALVE RETURN (Valve return timer / former name : TIMER 20) Default : 300 Setting range : 1 – 9999 [msec] 【Function】 ・ This timer starts functioning when the judgment delay timer comes up, and UECD switch off the valve (valve on) when this timer comes up. REVERSE ROTATION (Reverse rotation complete delay timer / former name : TIMER 21) (Not used now) Default : 300 Setting range : 0 – 9999 [msec] 【Function】 ・Use this timer when 9 is set to TIGHTENING MODE. Not used now PIN...
Page 43
42 YEAR Default : 0 Setting range : 0 – 99 [Year] 【Function】 ・This is to set the year of calendar timer of UECD. ・Enter 0, and the year of calendar timer is set to [Year 2000]. Enter 6, and the year of calendar time is set to [Year2006]. MONTH Default : 0 Setting range : 1 – 12 [Month] 【Function】 ・This is to set the month of calendar timer of UECD. DAY Default : 0 Setting range : 1 – 31 [Day] 【Function】 ・This is to set the day of calendar timer of UECD. HOUR...
Page 44
43 10.4. Data output setting Determine the contents of the output data and memory data sent through the serial port of the rear panel of UECD controller. UEC NO. (former name : MODE 98) Default : 1 Setting : 1 – 25 【Function】 Give every UECD its own number when plural UECDs are in use connected to PC by RS232C. OUT. MOVEMENT (former name : MODE 58) Default : 0 Setting : 0 Output all data through RS232C Setting : 1 Output only the following errors through...
Page 45
44 BIT (Bit length select for the RS232C output / former name : MODE 61) Default : 1 Setting : 0 7 bit Setting : 1 8 bit 【Function】 This is to determine the bit length of output data sent through data output RS232C port. STOP (Stop bit select for the RS232C output / former name : MODE 62) Default : 0 Setting : 0 1 bit Setting : 1 2 bit 【Function】 This is to determine the stop bit of output data sent through data output RS232C port. PARITY (Parity bit select for the...
Page 46
45 DECISION (Fastening judgment output select / former name : MODE 69) Default : 1 Setting : 0 Not output Setting : 1 Output 【Function】 This is to determine whether include or not the judgment in output data sent through data output RS232C port. Contents ASCII code HEX code TORQUE OK @ 40H START LEVEL ERROR C 43H CYCLE ERROR D 44H INITIAL ERROR E 45H CYCLE OVER ERROR F 46H INCOMPLETE JOB ERROR G 47H TORQUE LOW NOKK H 48H TORQUE HIGH NOK I 49H PULSE LOW NOK L 4CH...
Page 47
46 ID DATA SLCT (ID data output select) Default : 0 Setting : 0 Not output Setting : 1 Output 【Function】 This is to determine whether include or not ID number in output data sent through data output RS232C port. ID DATA NUMB. (ID data digit number) Default : 0 Setting range : 1 - 48 【Function】 This is to determine the digit number of VIN NO. The digit that is not used should be filled with [0].
Page 48
47 10.5. Tool Control UECD can memorize the total fastening number and pulse number since a tool is brought into use. It enables UECD to provide a notice of simple maintenance such as oil change by [WARNING COUNT/PULSE] and parts replacement/overhaul by [REPAIR COUNT/PULSE]. TIGHTENING COUNT (Total tightening count number [1 unit : 10,000 fasteners]) Default : 0 Setting range : 0 – 99999 [1 unit : 10,000 fasteners] ・This is total fastening number of the tool now in use since...
Page 49
48 WARNING PULSE (Warning pulse blow number [1 unit : 10,000 pulses]) Default : 00 Setting range : 0 – 9998 [1 unit : 10,000 pulses] ・UECD displays a warning message when the total pulse blow number reaches preset pulses. ・Set the number of pulse blow that you are going to repair like oil change a tool next time. 【Display status when number of pulse blow reaches warning pulse】 ・Buzzer sounds. Press to stop. ・7 segment displays [kcP.E.] Note: Set [0] when not use. REPAIR COUNT...
Page 50
49 10.6. IN/OUT PUT (Setting of signal allocations of input/output terminal board) Signal allocations of input and output terminal board is free format. You can change signal allocations as required by setting. Setting of input terminals Set the signal allocations of input terminals by IN TERMINAL 1 to IN TERMINAL 5. Default and name of terminal Setup item Default (function) Name of terminal IN TERMINAL 1 1 (LS1) LS1 IN TERMINAL 2 2 (START) START IN...