Aimco Brakes Monitor UECD4800 Instruction Manual
Here you can view all the pages of manual Aimco Brakes Monitor UECD4800 Instruction Manual. The Aimco Brakes manuals for Monitors are available online for free. You can easily download all the documents as PDF.
Page 31
30 TIME CONT. ST. (Compulsory judgment) (former name: MODE 6) Default : 0 Setting : 0 Not use Setting : 1 Stops the tool and makes the compulsory judgment when cycle error detection timer comes up. 【Function】 ・Use when you want to control fastening time without cycle error detection. ・UECD compulsory switches on solenoid valve to stop the tool and provides judgment if the tool fails to reach torque cut value beyond start torque value after cycle error detection timer comes up....
Page 32
31 LINE CNT. SELECT (Line control method select) (former name : MODE 14) Default : 0 Setting : 0 UECD is always ready to count down the fasteners, and provides the judgment at the time of limit switch is switched on. UECD provides COUNT OK judgment if the preset number of fasteners is fastened up. When the LS (limit switch) 1 terminal is switched on, UECD is reset and ready for next operation. UECD provides COUNT NOK if any fasteners are left unfastened when LS1 is switched on....
Page 33
32 Setting : 2 Switch on the limit switch, and the operation starts and UECD provides the judgment when the timer comes up. Operation starts by switching on LS1 terminal, and the line control timer starts functioning. UECD provides COUNT NOK if the line control timer comes up before the preset number of fasteners is fastened up. Note: When COUNT NOK is corrected to COUNT OK, the COUNT OK output becomes 1 pulse (1 sec). Setting: 3 Limit switch is not used, but the...
Page 34
33 Setting 4 By any of WORK 1 – 5 signal input, UECD gets ready to start fastening of the selected work number. Set 1 to WORK SIG. SEL. When the preset fasteners are fastened up, COUNT OK signal terminal is switched on corresponding to the selected work number. [WORK 2 COUNT OK] output terminal is switched on when UECD provides COUNT OK of work No. 2. Set up the COUNT OK signal output duration time per work number in COUNT OK of TIMER SETTING. UECD provides COUNT OK signal output...
Page 35
34 ALARM BUZZER (Fastening confirmation buzzer output) (former name : MODE 15) Default : 0 Setting : 0 Buzzer does not sound. Setting : 1 Buzzer sounds for every OK fastener. 【Function】 ・Buzzer gives 1 pulse sound for every OK fastener, and 2 pulses sound for fastener COUNT UP. ST. TORQUE ERROR (Start torque error detection) (former name : MODE 16) (Not used now) Default : 0 Setting : 0 Not detect the start torque error Setting : 1 Detect the start torque error Note: Set...
Page 36
35 PULSE HIGH (Pulse number upper limit value [pulse]) (former name : MODE 35) Default : 100 Setting range : 1 – 9999 (Pulse number low limit value, maximum 9998
Page 37
36 WORK SIG. SEL. (Work signal combination) (former name : MODE 29) Default : 0 Setting : 0 UECD changes up to 8 work numbers by using the terminals of WORK A, WORK B and WORK C. Setting : 1 UECD changes up to 5 work numbers by using the input terminals of WORK 1-1 to WORK 1-5. ・Setting 1 is used when LINE CNT. SELECT is set with 4. ANGLE DETECT (Spare for angle detect) (Not used now) Default: 0 Setting: 0, 1, 2, 3 or 4 Not used now ANG LOW LMT (Angle low limit value...
Page 38
37 SNUG TRQ (Snug torque) (Not used now) Default: 15.0 Setting range : 0.0 – 999.8 Setting condition : Start torque value < snug torque value < CUT torque value 【Function】 ・This is the torque from when UECD started measuring the angle. Not used now ANG CUT (Angle CUT value) (Not used now) Default : 999 Setting range : 0 - 999 【Function】 This is the fastening stop angle judgment value when the angle control is effective. Not used now ANG JUDG SEL (Angle judgment select)...
Page 39
38 PC COMM. SPEED (PC communication speed / former name : MODE 46) Default : 3 Setting : 1 9600 bps Setting : 2 19200 bps Setting : 3 38400 bps 【Function】 Note: This is to determine the communication speed between UECD and PC. This is not the communication speed of the data output port in rear of UECD. Note: Switch off UECD after you change the setting value of the PC port communication speed. Setting value will not be overwritten unless UEC is once switched off....
Page 40
39 10.3. TIMER (TIMER setting) JUDGMENT DELAY (Judgment delay timer / former name : TIMER 1) Default : 300 [msec] Setting range : 100 – 9999 [msec] 【Function】 ・This is to set time interval how long UECD delays judgment output after one fastening has been completed. ・Use this timer as the torque measurement end point when UECD is in control operation. ・Take torque spike after CUT into your consideration to determine length of this timer. 【Guideline of set value】...