Have a look at the manual ADT Security Services Safewatch Pro 3000 Entrepreneur 3000 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 68 ADT Security Services manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
– 51 – 6XPPDU\RI$XGLEOH9LVXDO1RWLILFDWLRQV &XVWRP(QJOLVKLVSOD\ 7RXFKSDGV SOUND CAUSE DISPLAY LOUD, INTERRUPTED* Touchpad & Ext.FIRE ALARM.FIRE is displayed; descriptor of zone in alarm is displayed. If a fire alarm is manually activated, zone number 95 will be displayed. LOUD, CONTINUOUS* Touchpad & Ext.BURGLARY/AUDIBLE EMERGENCY ALARM.ALARM is displayed. If programmed, descriptor of zone in alarm is also displayed ONE SHORT BEEP (not repeated) Touchpad onlya. SYSTEM DISARM. b . SYSTEM ARMING ATTEMPT WITH AN OPEN ZONE. c. BYPASS VERIFY.a. DISARMED/READY TO ARM is displayed.b. Number and descriptor of open protection zone is displayed. c. Numbers and descriptors of the bypassed zones are displayed (One beep is heard for each zone displayed). Subsequently, the following is displayed: DISARMED BYPASS /Ready to Arm. ONE SHORT BEEP (once every 40 secs) Touchpad onlya. SYSTEM IS IN TEST MODE. b, LOW BATTERY AT A TRANSMITTER.a. Opened Zone identifications will appear. b. LO BAT displayed with description of transmitter. TWO SHORT BEEPS Touchpad onlyARM AWAY.ARMED AWAY displayed. Red ARMED indicator lit. THREE SHORT BEEPS Touchpad onlya. ARM STAY, NIGHT-STAY, OR INSTANT. b. ZONE OPENED WHILE SYSTEM IS DISARMED. a. ARMED STAY or ARMED INSTANT displayed. Red ARMED indicator lit. b. CHIME displayed, descriptor of open protection zone will be displayed if the [Q ] key is pressed. RAPID BEEPING Touchpad onlya. TROUBLE. b. MEMORY OF ALARM. c. SYSTEM LOW BATTERY. d. EXT. SOUNDER WIRE FAIL.a. CHECK displayed. Descriptor of troubled protection zone is displayed. b. FIRE or ALARM is displayed; descriptor of zone in alarm is displayed. c. SYSTEM LO BAT displayed. d. BELL FAILURE is displayed. SLOW BEEPING Touchpad onlya. EXIT DELAY WARNING (if programmed). b. ENTRY DELAY WARNING.a. ARMED AWAY is displayed along with You May Exit Now. b. DISARM SYSTEM OR ALARM WILL OCCUR is displayed. Exceeding the delay time without disarming causes an alarm. * If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring .
– 52 – 5HJXODWRU\6WDWHPHQWVDQG:DUQLQJV NOTE: This is a “Grade A” Residential System RADIO FREQUENCY EMISSIONS Federal Communications Commission (FCC) Part 15 This device complies with part 15 of the FCC rules. Operation is subject to the following twoconditions: (1) This device may not cause harmful interference, and (2) this device must accept anyinterference received, including interference that may cause undesired operation. Industry Canada This Class B digital apparatus complies with Canadian ICES-003.Cet Appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. TELEPHONE/MODEM INTERFACE FCC Part 68 This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is alabel that contains the FCC registration number and Ringer Equivalence Number (REN). You mustprovide this information to the telephone company when requested. This equipment uses the following USOC jack: RJ31X This equipment may not be used on telephone-company-provided coin service. Connection to partylines is subject to state tariffs. This equipment is hearing-aid compatible. Industry Canada NOTICE: The Industry Canada Label identifies certified equipment. This certification means thatthe equipment meets telecommunications network protective, operational and safety requirementsas prescribed in the appropriate Terminal Equipment Technical Requirements document(s). TheDepartment does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to thefacilities of the local telecommunications company. The equipment must also be installed using anacceptable method of connection. The customer should be aware that compliance with the aboveconditions may not prevent degradation of service in some situations. Repairs to certified equipment should be coordinated by a representative designated by the supplier.Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may givethe telecommunications company to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the powerutility, telephone lines and internal metallic water pipe system, if present, are connected together,This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves but should contactappropriate electric inspection authority, or electrician, as appropriate. Ringer Equivalence Number Notice: The Ringer Equivalence Number (REN) assigned to each terminal device provides an indicationof the maximum number of terminals allowed to be connected to a telephone interface. Thetermination on an interface may consist of any combination of devices subject only to therequirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5.
– 53 – 5HJXODWRU\6WDWHPHQWV&RQWLQXHG Industrie Canada AVIS: l’étiquette d’Industrie Canada identifie le matériel homologué. Cette étiquette certifie que lematériel est conforme aux normes de protection, d’exploitation et de sécurité des réseaux detélécommunications, comme le prescrivent les documents concernant les exigences techniquesrelatives au matériel terminal. Le Ministère n’assure toutefois pas que le matériel fonctionnera à lasatisfaction de l’utilisateur. Avant d’installer ce matériel, l’utilisateur doit s’assurer qu’il est permis de le raccorder auxinstallations de l’enterprise locale de télécommunication. Le matériel doit également être installé ensuivant une méthode acceptée da raccordement. L’abonné ne doit pas oublier qu’il est possible que laconformité aux conditions énoncées ci-dessus n’empêche pas la dégradation du service danscertaines situations. Les réparations de matériel nomologué doivent être coordonnées par un représentant désigné par lefournisseur. L’entreprise de télécommunications peut demander à l’utilisateur da débrancher unappareil à la suite de réparations ou de modifications effectuées par l’utilisateur ou à cause demauvais fonctionnement. Pour sa propre protection, l’utilisateur doit s’assurer que tous les fils de mise à la terre de la sourced’energie électrique, de lignes téléphoniques et des canalisations d’eau métalliques, s’il y en a, sontraccordés ensemble. Cette précaution est particulièrement importante dans les régions rurales. Avertissement : L’utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoirracours à un service d’inspection des installations électriques, ou à un électricien, selon le cas. AVIS : L’indice d’équivalence de la sonnerie (IES) assigné à chaque dispositif terminal indiquele nombre maximal de terminaux qui peuvent être raccordés à une interface. La terminaison d’uneinterface téléphonique peut consister en une combinaison de quelques dispositifs, à la seulecondition que la somme d’indices d’équivalence de la sonnerie de tous les dispositifs n’excède pas 5.