Page 71
ADS XiLog+ System User Manual 65 7. Verify the settings and readings ret urned. Edit the settings as necessary, and c onsider the following: The Flow Channel header displays the current flow and meter readings. These updates every 10 seconds. If the flow rate does not match the meter reading, edit the FCAL value as necessary and click on the red arrow to send the new value to the logger. Edit the Meter Reading as necessary and click on the corresponding red arrow t o send the...
Page 72
ADS XiLog+ System User Manual 66 Appendix B: Meter Scaling Tables Elster/Kent Helix & Domes tic Meters Meter PU10/LRP (mm) FCAL Helix 2000 40-80 10 100-300 100 Helix 3000 40-80 10 100 10 150 100 Master 2000 40-50 1 80-100 10 PG100 Helix 4000 80-125 10/1000 150-300 100/10000 PSM PSM-PS15-PS20 (V100) 15/20 0.5 PSM-PS25-PS30 (V100) 25-30 5 PSM-PS40 (V100) 40 5 PSM-LT (V100) 15 & 20 0.5 MSM MSM-T (V210) 1 KVM-T (V200) 1 MSM-RS 10 Schlumberger/Actaris/Stream Domestic & Helix...
Page 73
ADS XiLog+ System User Manual 67 Meter CYBLE LF (mm) K=2.5 K=10 K=25 FlostarM 40-100 25 100 250 W oltex 50-100 25 100 250 150-300 250 1000 2500 400-500 2500 10000 25000 Sensus (Socam/Meinecke) Meter K510 K505R (mm) FCAL 510/510PR 15-20 1 0.5 501L 10 501LM 100 501JM 1000 510/510PR 25-30 10 5 501JM 100 R01.1 Cosmosil 50-125 100/1000 150-250 1000/10000 300-800 10000/100000 RD 01 Cosmos 50-125 100 WP/WS-Dyn amic 40-125 100/1000 10/1000 150- 300 1000/10000 100/10000...
Page 74
ADS XiLog+ System User Manual 68 ** Applies onl y to 7- digit counters ; the other FCALs apply to the 8- digit counters. Kent combination meters use a Helix 3000 meter as the main meter and a PSM -T as the secondary meter. Select the appropriate FCAL from the table above for each meter. The Master 2000 has been discontinued. Socam meters: *The 510 pulse unit is factory installed and cannot be removed. The FCAL is determined at the factory , and the table above displays the values...
Page 75
ADS XiLog+ System User Manual 69 Appendix C: Battery Life Measurement Interval Transmission Standard Internal Battery Double Internal Battery External Lithium Battery ≥1 minute Once per day >5 years >10 years ≥1 minute Once per hour >1.2 years >2.5 years >7 years ≥1 minute Once every 15 minutes ( for 10 hours a day) >0.7 year >1.5 years >5 years ≥1 minute Once every 15 minutes 0.3 year 0.7 year 2.5 years Power Supply Options Following are the internal...
Page 76
ADS XiLog+ System User Manual 70 Appendix D: Airfreight Restrictions APP3.1: Essential Safety Precautions before Air F reighting To pr event radio transmission on aircraft, remove the batteries and the removable external antenna (when applicable) from the equipment before transporting this product by air. IATA Hazardous Goods Regulation This product is powere d by a battery containing lithium D -cells. IATA (International Air Transport Association) regulation UN/ID number 3091, “...