SF/SG Series Operating Instructions10 11. Clear Entry FunctionM+CEtotal 3 55.00 WEIGHTUNIT PRICEPRICEtotal 2 45.00 WEIGHTUNIT PRICEPRICE TOTAL M+TOTAL M+XC Press to cancel this operation.MODE( (PC 0.00 00.00 WEIGHTUNIT PRICEPRICE entries.10. Calculating the Correct Change The purpose of this function is to allow the operator to determine the correct change to return to the customer once payment has been made. Example: There have been 4 entries and the total cost of the transaction is $80.00. Step 1:Press . The scale displays: Step 2: Enter the customer payment using the numerical keypad (Example: $100) The scale displays: Step 3:Press . The scale displays: The CE key is designed to clear the last entry made using the key, which places entries into memory for totaling. Step 1: You have entered a value with the M+ key and wish to cancel it. Example: Assume that you entered 3 values totaling $55.00. The last (3rd) entry was $10.00. Step 2:Press . The scale displays: Step 3:Press . The scale displays: Note: • Only the last M+ entry can be cleared from memory using the CE key. • Pressing the key while in the TOTAL mode will delete all entries in memory. • Pressing the key will also delete: Pressing the key will not delete: 1. Active PLU entries. 2. Active numerical keypad entries. 3. Active key entries. 4. Improper entry of money received from a customer.MODE ( (total 480.00 WEIGHTUNIT PRICEPRICECHANGE1 20.00 CH WEIGHTUNIT PRICEPRICE TOTAL M+Rece iu 100.00 80.00 WEIGHT UNIT PRICEPRICE TOTAL M+Note: Press if an error is made while entering the amount of money received from the customer.CMODE ( (CC (The condition in step 2 in “9. Multiplier Function”)
SF/SG Series Operating Instructions12. Automatic Cancellation of a Unit Price In very busy applications, it may be more convenient for the Unit Price entry to return to zero after each operation. To do this, press while the display is in normal operation. Automatically clears the unit price. Does not automatically clears the unit price. While the display shows the above, press again to change the setting. “F” functions allow the programming of various functions of the SF/SG scale. The following is a brief description of these functions and how to program them. Step 1:Starting with the power off, press and hold and turn on the power switch. The scale displays: Step 2: Press to select the desired “F” function group. Step 3: Use the numerical keypad to select a setting for each function. Press to cancel the selection. Press to move to the next “F” function. Press to store each setting selected. 11CHANGE1 ut c WEIGHT UNIT PRICEPRICE TOTAL M+ Ut nc WEIGHT UNIT PRICEPRICE TOTAL M+13. Setting “F” FunctionsCHANGE1ZERO0F 1 - WEIGHTUNIT PRICEPRICE TOTAL M+*F 1 - 1 UNIT PRICECMEM*F1-1 F4-4F2-0 F3-8 F5-1 F6-0F7-1Note: To use this function, F2 must be set to 0. Refer to “13. Setting “F” Functions”.“F” Functions continued...
SF/SG Series Operating InstructionsF1: Auto display off0: Yes1: No F2: Cancellation of unit price0: Selectable1: No 2: Yes F3: Output Data0: Key trigger mode 11: Key trigger mode 2 (Refer to the note below.)2: Command mode3: Stream mode 4: Key trigger mode 3 with delay 5: Key trigger mode 3 without delay 6: Not used 7: Not used 8: Label printer mode F4: Baud Rate0: 600 bps1: 1200 bps 2: 2400 bps3: 4800 bps 4: 9600 bps F5: Parity Bit0: 7 bits (Even)1: 8 bits (No parity) F6 and F7: Not usedNormally F6=0, F7=112Note: A scale that has totaling and multiplier functions can use F3 = 4 or 5. F3=8 is used when the SF/SG scale is connected to an AD-8124 label printer.Settings
130 SF/SG Series Operating Instructions14. Connecting the Scale to the AD-8124 Label Printer 14-1 Confirming the SF/SG Program Version Confirm the SF/SG program version as follows: Step 1:While holding down the ZERO key ( ) of the numerical keypad , turn the power switch on. Step 2:When “888888 ” appears, the scale program version is earlier than 4.00. When “rP XXX ” appears, the scale program version is 4.00 or later. Earlier than 4.00 4.00 or laterNote about Connection to the AD-8124 • To connect the SF/SG scale to the printer, use an RS-232C crossover cable (D-Sub 9-pin socket type) such as an AX-KO1371-200 (2 m). • To get optimum performance from the AD-8124, use the SF/SG program version “rP 4.00 ” or later. Some functions can not be used with the earlier versions, such as the PLU number printing, printer internal clock setting and scale PLU unit price data changing. • The totaling function and multiplier function of the SF/SG scale can not be used. • When an item is weighed and the data is sent to the printer, the next data transmission is not available until the item is removed from the scale. 14-2 Setting the “F” Functions Set the “F” functions depending on the scale program version as follows: Program version 4.00 or later: (1) Output modeLabel printer modeF3=8 (2)Baud rate9600 bpsF4=4 (3)Parity bit8 bits (No parity)F5=1 Program version earlier than 4.00: (1) Output modeKey trigger mode 1F3=0 (2)Baud rate9600 bpsF4=4 (3)Parity bit8 bits (No parity)F5=1 AD-8124 continued...888888888888888888 WEIGHTUNIT PRICEPRICE rP 4.00 WEIGHTUNIT PRICEPRICE
14 SF/SG Series Operating Instructions14-3 Setting the printer internal clock Set the printer internal clock as follows: Example:Set the clock to 9:45, June 10, 2001. Step 1:While holding down , turn the scale’s power switch on. All the displays indicate “- - - - - - -” as shown below: Assure that the printer power switch is turned on. Step 2:Enter the date and time using the numerical keypad. Enter 4 digits for the year, 2 digits for the month, 2 digits for the day, 2 digits for the hour in 24-hour format and 2 digits for the minute, in that order to send the data to the printer. The printer prints the date in the order it receives the data. To print the date in the Year - Month - Day order, go to step 3. To print the date in the Month - Day - Year order, go to step 5. To print the date in the Day - Month - Year order, go to step 7. Step 3: Using the numerical keypad, enter “2”, “0”, “0”, “1”, “0”, “6”, “1”, “0”, “0”, “9”, “4” and “5” in this order. If an error is made, press to clear the values. And re-enter the values. SF series SG series Step 4: Press the PLU 1 key. The data will be sent to the printer and the scale will return to the normal weighing mode. If the scale will not return to the normal weighing mode, check the values entered. Step 5: Using the numerical keypad, enter “0”, “6”, “1”, “0”, “2”, “0”, “0”, “1”, “0”, “9”, “4” and “5” in this order. If an error is made, press to clear the values. And re-enter the values. SF series SG series AD-8124 continued...T TARENote: The time will not be printed.C 2001 0610 0945 WEIGHTUNIT PRICEPRICE 2001 WEIGHT 0610 UNIT PRICE 0945 PRICEC 0610 2001 0945 WEIGHTUNIT PRICEPRICE 0610 WEIGHT 2001 UNIT PRICE 0945 PRICE- - - - - -- - - - - -- - - - - - WEIGHTUNIT PRICEPRICE
15 SF/SG Series Operating InstructionsStep 6: Press the PLU 2 key. The data will be sent to the printer and the scale will return to the normal weighing mode. If the scale will not return to the normal weighing mode, check the values entered. Step 7: Using the numerical keypad, enter “1”, “0”, “0”, “6”, “2”, “0”, “0”, “1”, “0”, “9”, “4” and “5” in this order. If an error is made, press to clear the values. And re-enter the values. SF series SG series Step 8: Press the PLU 3 key. The data will be sent to the printer and the scale will return to the normal weighing mode. If the scale will not return to the normal weighing mode, check the values entered 14-4 Combining the designed data with a PLU number Assign a PLU number to a label number of the designed data stored in the AD-8124 as follows: Example:Assign the PLU number 5 to the label number 12. Step 1:While holding down , turn the scale’s power switch on. Assure that the printer power switch is turned on. The WEIGHT display reads “Set Ln”. A 3-digit label number “000 ”appears in the PRICE display for the SF series scale and in the UNIT PRICE display for the SG series scale. SF series SG seriesC 1006 2001 0945 WEIGHTUNIT PRICEPRICE 1006 WEIGHT 2001 UNIT PRICE 0945 PRICENote: The label numbers are the same as the PLU numbers at the time of printer shipment.M+ set ln 000 WEIGHTUNIT PRICEPRICEset ln WEIGHT UNIT PRICE 000 PRICE AD-8124 continued...
SF/SG Series Operating Instructions16Step 2: Using the numerical keypad, enter a 3-digit label number. If an error is made, press to clear the values. And re-enter the values. SF series SG series Step 3: Press the PLU key to assign to the label number, in this example, the PLU 5 key. . The PLU number will be sent to the printer and the scale will return to the displays described in step 1. If the label number is “000 ”, it will not be sent to the printer. Step 4: Repeat steps 1 through 3 as necessary. Step 5: After the setting has been completed, turn the power switch off. 14-5 Changing the scale PLU unit price data Using the PLU software provided with the AD-8124, the PLU unit price data, stored in the scale, can be changed via the AD-8124 using a personal computer. If the data sent to the scale via the AD-8124 is not appropriate, “Err 10 ” appears in the UNIT PRICE display. To release the error, press . Then, re-send the data to the scale. For details about changing the scale PLU unit price data using the PLU software, refer to the AD-8124 label printer instruction manual.C set ln 012 WEIGHTUNIT PRICEPRICEset ln WEIGHT UNIT PRICE 012 PRICEC