Page 1
SF/SG Series Price Computing Scales Instruction ManualWEIGHT PRICE UNIT PRICE 88888 8888888 888888 kg $ O Net Zero Total M+ ((XCEMEM Change* T M+ 9101112131415234567 81617 1 242526272829301819202122231234560 79 C 8 Change 125678234 11 WEIGHT kg UNIT PRICE $/kg PRICE $ TTLM+CHANGE NETZERO 88888 8888888888888 C3456897 021M+*OOOCEMEMO ((XT1 910SF Series SG Series $/kgSF-15KA Max. 15kg Min 0.1kg e=0.005kg ChangeWM:PD4000340
Page 2
SF/SG Series Instruction ManualIndex Item NumberDescriptionPage Unpacking and Inspecting 2 Specifications 3 Main Operating Components 4 1Zero Point Adjustment 5 2Tare Adjustment 5 3Keypad Tare Entry 6 4Setting a Unit Price 7 5Storing a Unit Price in Memory 8 6Recalling a Unit Price from Memory 8 7Totaling Multiple Items with Unit Prices Stored in PLU Memory 8 8Clearing Totaling Memory 9 9Multiplier Function 9 10Calculating the Correct Change 10 11Clear Entry Function10 12Automatic Cancellation...
Page 3
Thank you for purchasing our A&D SF/SG Series price computing scale. Before using your price computing scale, please read the operating instructions. Warning before connecting power plug: Thank You... –Do not place a load on the weighing pan before connecting the power supply. –Check the power requirement label next to the power switch on the lower left side of the body of the SF/SG scale to confirm that it corresponds to your local power requirements. Or when appropriate, check the AC adapter....
Page 4
Specification Table Operating Temperature: -10°C to 40°C / 14°F to 104°F; RH less than 85% *Note: 1. Rechargeable batteries are sold as an option. 2. D size batteries are not included with the unit and must be purchased locally. Price Model Capacity Display Type AC Type Battery Lookup Options Type Capability SF- 6KA 6 kg x 2 g VFDTowerAC hardwiredNone 30 RS-232C SF-15KA 15 kg x 5 g VFDTowerAC hardwiredNone 30 RS-232C SF-30KA 30 kg...
Page 5
SF/SG Series Main Operating ComponentsWEIGHT PRICE UNIT PRICE 88888 8888888 888888 kg $ $/kgSF-15KA Max. 15kg Min 0.1kg e=0.005kg 242526272829301718192021222391011121314151234567 168 0123 456 789((XCE. ..CChange MEM * T M+O Net Zero Total M+ ChangeMultiple displays •Weight of product •Zero & Tare •Price of product •Memory & total sale •Unit price of product ($/kg ) •Payment received •Change requiredPower Switch turns the power to the unit on and off. Change 125678234 11 WEIGHT kg...
Page 6
SF/SG Series Operating Instructions1. Zero Point Adjustment The zero point is automatically adjusted when power is turned on. If the display shows a positive or negative weight, the scale must be re-zeroed. How to re-zero: Step 1: Assure that nothing is on the weighing pan. Step 2: Press . Step 3: The WEIGHT display should read: When weighing with a container, it is necessary to TARE out the weight of the container in order to get an accurate price/weight reading. How to operate...
Page 7
SF/SG Series Operating Instructions3. Keypad Tare Entry In addition to the tare adjustment described on the previous page, another tare adjustment is available. It is to enter a TARE value with the numerical keypad. How to enter a TARE using the numerical keypad: Step 1: With nothing on the weighing pan, turn on the SF/SG scale. The display should read: If a unit price has previously been entered, the display may read, for example “2.00 ”, instead of “...
Page 8
SF/SG Series Operating Instructions4. Setting a Unit Price Step 1: Enter a unit price using the numerical keypad. Up to 6 digits may be entered. Example: Enter a unit price of $5.50 Step 2: Unit price entry must be completed within 3 seconds. Any delay beyond 3 seconds will require the unit price to be re-entered.Note about keypad tare entry: • When a TARE weight has been set, an error message “ Err tr ” will appear as shown below, if you enter a lower value than the TARE weight. • If...
Page 9
SF/SG Series Operating Instructions5. Storing a Unit Price in Memory Unit prices can be stored in memory for quick recall, by assigning a unit price to a Price Lookup (PLU) key. The SF series scale has 30 PLU keys, thus can store 30 unit prices. The SG series scale has 12 PLU keys, thus can store 12 unit prices. Assign a unit price to a PLU key as follows: Step 1: Enter a unit price using the numerical keypad. Step 3: Press the desired PLU key within 3 seconds of entering the unit price. ( If you do not...
Page 10
SF/SG Series Operating Instructions9. Multiplier Function (Max. pieces allowed = 99; Max. unit price = 999999) Not all items are sold by the weight. Items such as canned goods and apples may be sold by the piece. The SF/SG scale allows the operator to calculate all items purchased, those that require weigh/price calculation and those that are sold by the piece, and provides the total price. Example: A customer purchases 10 cans of tuna fish at a cost of $1.00 per can. Step 1: Enter the unit price using...