Page 1

SF/SG Series
Price Computing Scales
Instruction ManualWEIGHT
PRICE
UNIT PRICE
88888
8888888
888888
kg
$
O
Net   Zero
Total    M+
((XCEMEM
Change*
T
M+
9101112131415234567
81617
1
242526272829301819202122231234560
79
C
8
Change
125678234
11
WEIGHT    kg         UNIT PRICE  $/kg               PRICE     $
TTLM+CHANGE
NETZERO   88888   8888888888888
C3456897 021M+*OOOCEMEMO
((XT1
910SF Series SG Series
$/kgSF-15KA
Max. 15kg Min 0.1kg e=0.005kg ChangeWM:PD4000340 

Page 2

SF/SG Series Instruction ManualIndex
Item NumberDescriptionPage
Unpacking and Inspecting 2
Specifications 3
Main Operating Components 4
 1Zero Point Adjustment 5
 2Tare Adjustment 5
 3Keypad Tare Entry 6
 4Setting a Unit Price 7
 5Storing a Unit Price in Memory 8
 6Recalling a Unit Price from Memory 8
 7Totaling Multiple Items with Unit Prices Stored in PLU Memory 8
 8Clearing Totaling Memory 9
 9Multiplier Function 9
10Calculating the Correct Change 10
11Clear Entry Function10
12Automatic Cancellation...

Page 3

Thank you for purchasing our A&D SF/SG Series price computing scale. Before using your
price computing scale, please read the operating instructions.
Warning before connecting power plug: Thank You...
–Do not place a load on the weighing pan before connecting the power supply.
–Check the power requirement label next to the power switch on the lower left side of the body
of the SF/SG scale to confirm that it corresponds to your local power requirements. Or when
appropriate, check the AC adapter....

Page 4

Specification Table
Operating Temperature: 
-10°C to 40°C / 14°F to 104°F; RH less than 85% *Note: 
1. Rechargeable batteries are sold as an option.
2. D size batteries are not included with the unit and must be purchased locally.      Price
  Model  Capacity  Display    Type    AC Type      Battery     Lookup   Options
       Type   Capability
SF-  6KA 6 kg x   2 g     VFDTowerAC hardwiredNone          30 RS-232C
SF-15KA    15 kg x   5 g     VFDTowerAC hardwiredNone          30 RS-232C
SF-30KA    30 kg...

Page 5

SF/SG Series Main Operating ComponentsWEIGHT
PRICE
UNIT PRICE
  88888
8888888
 888888
kg
$
$/kgSF-15KA
Max. 15kg  Min 0.1kg   e=0.005kg 
242526272829301718192021222391011121314151234567
168
0123
456
789((XCE.
..CChange
MEM
*
T
M+O
Net     Zero
Total    M+
ChangeMultiple displays
•Weight of product
•Zero & Tare
•Price of product
•Memory & total sale
•Unit price of product ($/kg )
•Payment received
•Change requiredPower Switch turns the power to
the unit on and off.
Change
125678234
11
WEIGHT    kg...

Page 6

SF/SG Series Operating Instructions1. Zero Point Adjustment
The zero point is automatically adjusted when power is turned on. If the display shows a positive or
negative weight, the scale must be re-zeroed.
How to re-zero:
Step 1: Assure that nothing is on the weighing pan.
Step 2: Press                       .
Step 3: The WEIGHT display should read:
When weighing with a container, it is necessary to TARE out the weight of the container  in order to
get an accurate price/weight reading.
How to operate...

Page 7

SF/SG Series Operating Instructions3. Keypad Tare Entry
In addition to the tare adjustment described on the previous page, another tare adjustment is available.
It is to enter a TARE value with the numerical keypad.
How to enter a TARE using the numerical keypad:
       Step 1:  With nothing on the weighing pan, turn on the SF/SG scale.
                     The display should read:
                 If a unit price has previously been entered, the display may read, for example “2.00 ”,
   instead of  “...

Page 8

SF/SG Series Operating Instructions4. Setting a Unit Price
Step 1: Enter a unit price using the numerical keypad. Up to 6 digits may be entered.
 Example: Enter  a unit price of $5.50
Step 2: Unit price entry must be completed within 3 seconds. Any delay beyond 3 seconds  
        will require the unit price to be re-entered.Note about keypad tare entry:
•  When  a TARE weight has been set, an error message “ Err tr  ” will appear as shown below, if you
enter a lower value than the TARE weight.
•   If...

Page 9

SF/SG Series Operating Instructions5. Storing a Unit Price in Memory
Unit prices can be stored in memory for quick recall, by assigning a unit price to a Price Lookup (PLU)
key. The SF series scale has 30 PLU keys, thus can store 30 unit prices. The SG series scale has 12
PLU keys, thus can store 12 unit prices.
Assign a unit price to a PLU key as follows:
Step 1: Enter a unit price using the numerical keypad.
Step 3: Press the desired PLU key
within 3 seconds of entering
the unit price.
( If you do not...

Page 10

SF/SG Series Operating Instructions9. Multiplier Function  (Max. pieces allowed = 99; Max. unit price = 999999)
Not all items are sold by the weight. Items such as canned goods and apples may be sold by the piece.
The SF/SG scale allows the operator to calculate all items purchased, those that require weigh/price
calculation and those that are sold by the piece, and provides the total price.
Example: A customer purchases 10 cans of tuna fish at a cost of $1.00 per can.
Step 1:  Enter the unit price using...
Start reading A&D Scale SFSG Series User Manual

Related Manuals for A&D Scale SFSG Series User Manual