Page 11
TSE-P 02.01 LF 11/35 599 34 60-32 3. SPECIFICATIONS FOR ACTUATORS AND SENSORS 3.1 COMPONENTS TYPE OF COMPONENT POWER AVAILABLE TYPE OF CONTROL Wash pumpMax 250WTriac & relay Drain pumpMax 100WTriac & relay Washing heaterMax 2100W Relay Water fill solenoidMax 10WTriac Regeneration solenoidMax 10WTriac Detergent/Rinse-aid solenoidMax 10WTriac Fan motorMax 10WTriac 3.2 SENSORS TYPE OF SENSOR TYPE OF READING TYPE OF COMPONENT Salt sensor Digital 5 V Reed Rinse-aid sensor Digital 5 V Reed Temperature...
Page 12
TSE-P 02.01 LF 12/35 599 34 60-32 4 OPERATION OF THE WASH / DRAIN MOTOR 4.1 WASH MOTOR CHARACTERISTICS This dishwasher is fitted with a single-phase variable-speed asynchronous motor. A tachimetric sensor, fitted to the interior of the motor, constantly monitors the speed of the motor, which is transmitted to the electronic control system. MEASURING THE SPEED OF THE MOTOR The operation of the motor during the washing cycle is controlled by the electronic control system, which operates the motor at...
Page 13
TSE-P 02.01 LF 13/35 599 34 60-32 4.3 WASHING SYSTEM This appliance features the conventional washing system, in which the mechanical action is obtained by the rotation of the single motor. This drives the water into the hydraulic circuit and actions the two spray arms simultaneously. DEFINITION OF THE WASHING SYSTEM In order to optimize the washing programmes, this appliance offers two different washing systems; these are governed by the electronic control system, which powers the motor at two...
Page 14
TSE-P 02.01 LF 14/35 599 34 60-32 4.5 5. HYDRAULIC CIRCUIT KEY 1. Anti-flooding device 11. Sump 2. Anti-overflow device 12. Pressure switch 3. Fill solenoid 13. Connector siphon for anti-overflow device 4. Air-Break 14. Cutting valve sump 5. Intake valve for regeneration chamber 15. Wash motor 6. Regeneration chamber 16. Drain motor 7. Vent valve 2 nd regeneration chamber 17. Non-return valve 8. Regeneration solenoid 18. Delivery valve to upper spray arm 9. Salt container 19. Upper sprayer 10. Resin...
Page 15
TSE-P 02.01 LF 15/35 599 34 60-32 5.1 WATER FILL - FUNCTIONAL SYSTEM For dishwashers fitted with motors with tachimetric sensors (1.5 New Generation models), the electronic control system is designed to control the water fill by identifying the signals received from the pressure switch (which thus acts as a pressure sensor). The tachimetric sensor which signals the speed of the motor to the electronic control system is independent of the water fill level control function. 5.1.1 BLOCK DIAGRAM OF...
Page 16
TSE-P 02.01 LF 16/35 599 34 60-32 5.2 WATER FILL CONTROL The quantity of water necessary to perform the washing cycle is determined exclusively by the closure of the contact on the pressure switch, which switches from EMPTY to FULL. In order to assure that the hydraulic circuit is correctly balanced, this system ensures that, if the pressure switch re-opens on EMPTY, the water is replenished until the pressure switch returns to FULL. The fill phase is subdivided into the following sub-phases: WATER...
Page 17
TSE-P 02.01 LF 17/35 599 34 60-32 5.2.6 WATER FILL TIME During the entire duration of the fill phase (i.e. from sub-phase 5.2.1 to sub-phase 5.2.4), the solenoid valve may remain in the open position for a maximum overall time of 4 minutes. Within this period, the system detects whether the pressure switch signal has stabilized on FULL. If the pressure switch signal stabilizes on FULL (sub-phase 5.2.4) after this 4-minute period during which the solenoid is open, a Time-out is generated and the...
Page 18
TSE-P 02.01 LF 18/35 599 34 60-32 5.4 CONTROL OF DRAIN CYCLE When the washing cycle ends, the appliances passes to the drain phase. In this phase, in order to ensure that the hydraulic circuit is empty before the start of the subsequent phase (water fill), a control procedure is carried out at the end of the drain phase to check that the contact of the pressure switch is open on EMPTY. If this is the case, the appliance passes to the subsequent phase. If, due to a malfunction in the drain phase, the...
Page 19
TSE-P 02.01 LF 19/35 599 34 60-32 5.5 SPECIAL REGENERATION CYCLE With the new water softening system, the “special regeneration” process is controlled electronically, and is subdivided into 5 levels as follows: REGENERATION VALUES LEVEL INDICATION WASHING CYCLEFILL PHASESWATER HARDNESS DEFINITIONLed [ LD1 ]AUTONOMY REGENERATION Nº º F (TH) º D (dH) WH11 flash No regeneration - 0 > 8 0 > 4 WH22 flashes 5 cycles in the 6th cycle 24 9 > 30 5 > 18 * WH33 flashes 3 cycles in the 4th cycle 16 31 > 50 19 >...
Page 20
TSE-P 02.01 LF 20/35 599 34 60-32 6 «ACTIVE» DRYING SYSTEM The “Active Plus” drying system features a close integrated circuit with bidirectional convective movement ; air is drawn in from the exterior thus allowing the circulation of the inner warm air. 6.1DEFINITION OF THE SYSTEM The drying system is based on the natural circulation of the hot air produced during the hot rinse cycle, in which the steam (humid hot air) circulates slowly through two ducts, this activating the process of condensation....