Page 21
TSE-P 02.01 LF 21/35 599 34 60-32 7. SAFETY FEATURES - CONTROLS - ALARMS Dishwashers with electronic control systems include a number of safety features which protect the components whether the appliance is switched off or in operation 7.1 DEFINITION In the event of a fault that might affect the operation of the appliance, the electronic control system activates a specific safety device; in most cases, this immediately activates a Time-out which interrupts the washing cycle. The alarm situation is...
Page 22
TSE-P 02.01 LF 22/35 599 34 60-32 7.2 DISPLAYING ALARM CONDITIONS STORED IN MEMORY This procedure can be performed by service engineers only in order to check for any alarm conditions stored in the memory of the electronic control system. The procedure is accessed by pressing a combination of keys, and enables the service engineer to identify the fault (whether currently existing or occurring previously). The Alarm condition stored in memory is indicated by LEDs [LD9], [LD10], [LD11] (flashing)...
Page 23
TSE-P 02.01 LF 23/35 599 34 60-32 7.4 DESCRIPTION OF SAFETY FEATURES AND ALARMS 7.4.1WATER FILL TIME-OUTALARM [A L 5] Led [LD9] This Time-out is activated only during the water fill phases. The control system definitively switches off the fill solenoid valve. Counting of time “T” starts when the solenoid valve opens and ends when the signal from the pressure switch stabilizes on “full”. The maximum time for aperture of the fill solenoid (“T”) is 4 minutes for the entire fill phase; if this time...
Page 24
TSE-P 02.01 LF 24/35 599 34 60-32 7.4.3ANTI-FLOODING CONTROL SYSTEMALARM [A L 4] Leds [LD9] + [LD10] This control system is operative during the washing phases only, and not in the water fill phases, in which case is it connected to the safety device (see paragraph 7.4.1 “W ater Fill Time-out”). A float-actioned mechanical sensor positioned on the bottom of the appliance trips a microswitch which is connected in series to the fill solenoid, thus disconnecting the solenoid. Intervention of the...
Page 25
TSE-P 02.01 LF 25/35 599 34 60-32 7.4.6MOTOR INOPERATIVEALARM [A L 7] Leds [LD10] + [LD11] This control system is operative during the entire washing cycle. Jamming of the motor is detected by the tachimetric sensor; this also makes it possible to check for a faulty tachimetric sensor using the following procedure. When the motor is switched on, it must reach a speed of 2000 rpm within 5 seconds ; if this does not occur, an alarm condition is generated. Possible causes: a. Motor winding interrupted...
Page 26
TSE-P 02.01 LF 26/35 599 34 60-32 7.5 SUPPLEMENTARY SAFETY FEATURES 7.5.1ANTI-PRESSURE SURGE Pressure surge sometimes occurs during the hot wash phases when operation of the motor is resumed after the cycle has been interrupted. This phenomenon may result in excessive noise, rattling of the dishes and slight leakage of water from the door seal. The electronic control system performs a procedure which prevents this phenomenon by controlling the operation of the motor. The control procedure consists...
Page 29
TSE-P 02.01 LF 29/35 599 34 60-32 8.3 TABLE OF WASHING PROGRAMMES The table lists all the programmes stored in memory. The codes (A, B etc.) identify the programmes assigned (max. 5) to the individual appliances. Pre-wash Main washFirst rinseSecond rinseHot rinse Drying Plant Programmes Resin wash (option) Temperature Time after temperature Washing type Drain Resin wash (option) Temperature Time after temperature Temperature Time after temperature Washing type Drain Time Washing type Drain...
Page 30
TSE-P 02.01 LF 30/35 599 34 60-32 9. SERVICING 9.1 COMPONENT DIAGNOSTICS This test is used by service engineers only to check the efficiency of the main electrical components. To access the test procedure, it is necessary to press a combination of keys. Correct operation of the components to be tested can be checked rapidly. The component diagnostics procedure consists of 7 sequential phases:. The component selected is displayed by a code shown by LEDs [LD9], [LD10], [LD11] Press [S2] repeatedly to...