TSE-P  02.01  LF 31/35 599 34  60-32 9.2 FUNCTIONAL TESTING CYCLE
The functional testing cycle is an abbreviated washing programme for use by service engineers only.
The testing cycle enables the engineer to check all the functions which make up a traditional washing
cycle (in effect, the test simulates a normal cycle).
To access the test procedure, it is necessary to press a combination of keys. Correct operation of the
appliance can be checked rapidly.
The procedure is designed to perform the following...

Page 32

TSE-P  02.01  LF 32/35 599 34  60-32
9.3  CHECKING THE EFFICIENCY OF THE COMPONENTS
In order to facilitate testing of the components, a TEST PROCEDURE has been created showing the
contacts to which the probes of the tester should be connected and the theoretical reading for each
component.
9.3.1PROCEDURE (after removing the door)
Remove the modular connector from the control
board, connect the probes of the tester to the
points indicated in the table, and compare the
actual reading with the theoretical...

Page 33

TSE-P  02.01  LF 33/35 599 34  60-32 9.3.2COMPONENT CONNECTION DIAGRAM 

Page 34

TSE-P  02.01  LF34/35 599 34  60-32 9.4 T ABLE OF AL ARM CODES
In order to facilitate identification of an ALARM CONDITION indicated on the control panel and which
causes one of the safety features to intervene, the possible causes for each alarm condition are listed in
the table below together with suggested solutions.
Note:
- The control board is unlikely to be
the cause of an alarm condition, and
should therefore be checked last.
ALARMS
Codice LedsSAFETY DEVICE POSSIBLE CAUSES
WATER FILL TIME-OUTThe...

Page 35

TSE-P  02.01  LF
35/35 599 34  60-32 9.5  SUMMARY OF FUNCTIONS
This table contains a brief summary of the procedures for all the
functions available to the service engineer
Function Activation of function
Selection of response /
Commencement of function
Brief description / Comments
Keys LED (s)
Key LED(s)
Selection of
regeneration
[S1 + S2
]
S0 
(On/Off)
LD1
Lit for 5 seconds
 
the code stored in
memory flashes
S1
LD1
Lit for 5 seconds
 
the code stored in
memory flashes
(description on page 19 /...