Home > Yamaha > Home Theater System > Yamaha Dvx 1000 Owners Manual

Yamaha Dvx 1000 Owners Manual

Here you can view all the pages of manual Yamaha Dvx 1000 Owners Manual. The Yamaha manuals for Home Theater System are available online for free. You can easily download all the documents as PDF.

Page 361

MIDI Data Format361
DM1000 Version 2—Owner’s Manual
Appendix
Transmission
If [TABLE] is selected, operating a parameter specified in the [Control assign ta-
ble] will cause these messages to be transmitted if [Control Change Tx] is ON. 
The parameters that can be specified are defined in the Control Change Assign 
Parameter List.
If [NRPN] is selected, operating a specified parameter will cause data to be 
transmitted on the [Tx CH] if [Control Change Tx] is ON, using the four mes-
sages NRPN control...

Page 362

362Appendix C: MIDI
DM1000 Version 2—Owner’s Manual
Transmission
This message is transmitted on the [Tx CH] by key operations in the [MI-
DI]-[BULK DUMP] screen.
A bulk dump is transmitted on the [Rx CH] in response to a bulk dump request.
The data area is handled by converting seven words of 8-bit data into eight 
words of 7-bit data.
Conversion from actual data into bulk data
d[0~6]: actual data
b[0~7]: bulk data
b[0] = 0;
for( I=0; I

Page 363

MIDI Data Format363
DM1000 Version 2—Owner’s Manual
Appendix
2.12.2.6 User Defeined MIDI Remote bulk dump request 
format
The second and third bytes of the DATA NAME indicate the bank number.
2.12.2.7 User Defined Keys bulk dump format
The second and third bytes of the DATA NAME indicate the bank number.
Be aware that the state of the transmission destination will (in some cases) 
change if the same bank is being used.
2.12.2.8 User Defined Keys bulk dump request format
The second and third bytes of the...

Page 364

364Appendix C: MIDI
DM1000 Version 2—Owner’s Manual
2.12.2.11 Control change table bulk dump format
2.12.2.12 Control change table bulk dump request format
2.12.2.13 Program change table bulk dump format2.12.2.14 Program change table bulk dump request format
2.12.2.15 Equalizer library bulk dump format
The second and third bytes of the DATA NAME indicate the bank number.
0:Library no.1 – 199:Library no.200,
256:CH1 – 303:CH48, 384:BUS1 – 391:BUS8, 512:AUX1 – 519:AUX8, 768:STE-
REO, 8192:UNDO
256 and...

Page 365

MIDI Data Format365
DM1000 Version 2—Owner’s Manual
Appendix
2.12.2.17 Compressor library bulk dump format
The second and third bytes of the DATA NAME indicate the library number.\
0:Library no.1 – 127:Library no.128,
256:CH1 – 303:CH48, 384:BUS1 – 391:BUS8, 512:AUX1 – 519:AUX8, 7\
68:STE-
REO, 8192:UNDO
256 and following are data for the corresponding channel of the edit buf\
fer.
For reception by the DM1000, only the user area is valid. (36-127, 256-\
)
2.12.2.18 Compressor library bulk dump request...

Page 366

366Appendix C: MIDI
DM1000 Version 2—Owner’s Manual
2.12.2.22 Effect library bulk dump request format
The second and third bytes of the DATA NAME indicate the library number. 
(See above)
2.12.2.23 Channel library bulk dump format
The second and third bytes of the DATA NAME indicate the library number.
0:Library no.0 – 128:Library no.128,
256:CH1 – 303:CH48, 384:BUS1 – 391:BUS8, 512:AUX1 – 519:AUX8, 768:STE-
REO, 8192:UNDO
256 and following are the data for the corresponding channel of the edit buffer....

Page 367

MIDI Data Format367
DM1000 Version 2—Owner’s Manual
Appendix
2.12.2.28 Output patch library bulk dump request format
The second and third bytes of the DATA NAME indicate the library number. 
(See above)
2.12.2.29 Bus to Stereo library bulk dump format
The second and third bytes of the DATA NAME indicate the library number.
0:Library no.0 – 32:Library no.32, 256:current data, 8192:UNDO
For reception by the DM1000, only the user area is valid. (1-32, 256, 8192)
2.12.2.30 Bus to Stereo library bulk dump...

Page 368

368Appendix C: MIDI
DM1000 Version 2—Owner’s Manual
2.12.2.33 Automix bulk dump format
The second byte of the DATA NAME indicates the library number.
0:Library no.1 – 15:Library no.16, 256:current automix data
2.12.2.34 Automix bulk dump request format
The second and third bytes of the DATA NAME indicate the library number. 
(See above)
2.12.2.35 Plug-in effect card bulk dump format
The second byte of the DATA NAME indicates the slot number.
0:SLOT 1 – 1:SLOT 2
The data is not received if the Developer...

Page 369

MIDI Data Format369
DM1000 Version 2—Owner’s Manual
Appendix
2.12.3.1.2 Parameter Change basic format (Universal 
format)
*) For parameters with a data size of 2 or more, data for that size will be 
transmitted.
2.12.3.1.3 Parameter request basic format
2.12.3.1.4 Parameter request basic format (Universal 
format)
2.12.3.1.5 Parameter Address
Consult your dealer for parameter address details.
2.12.3.2 Parameter change (Edit buffer)2.12.3.3 Parameter request (Edit buffer)
2.12.3.4 Parameter change (Patch...

Page 370

370Appendix C: MIDI
DM1000 Version 2—Owner’s Manual
2.12.3.8 Parameter change (Backup memory) 
2.12.3.9 Parameter request (Backup memory)
2.12.3.10 Parameter change (Function call: Library store / 
recall)
Reception
When this is received, the specified memory/library will be stored/recal\
led. If 
this is received from Studio Manager or Cascade Link, the operation will\
 be ex-
ecuted, and then the result of execution will be transmitted as a Parame\
ter Re-
sponse.
Transmission
If [Parameter change Tx]...
Start reading Yamaha Dvx 1000 Owners Manual

Related Manuals for Yamaha Dvx 1000 Owners Manual

All Yamaha manuals