2-8Installation
Battery Charging Unit (BCU) Installation
Battery Charging Unit (BCU) Installation
The BCU provides power for the system during a power failure. The BCU connects to the Triad-S via the
connector on the bottom of the BKSU. The external gel cell batteries must provide 24V DC. This is generally
accomplished by connecting two 12 volt batteries in series. The BCU provides charging current to the
batteries during normal AC power operation at a maximum of about 0.5 amp. During battery operation,...

Page 343

Power Line Surge Protection
The AC outlet should be equipped with a power surge protection device or UPS. Systems using such devices
are more resistant to damage from power line surges than unprotected systems. Power line surges often
occur during normal operations and during violent thunderstorms,
Installation of a surge protector meeting the specifications described in the following paragraph may prevent
or minimize the damage resulting from power line surges.
The isolation transformer/surge protector...

Page 344

2-10Installation
BKSU and Main Board Assembly
BKSU and Main Board Assembly
The MBU is installed in the BKSU at the factory before the shipment. The MBU contains a lithium dry cell to
maintain memory and real-time clock functions. The battery is soldered to the MBU and connected to the
circuitry by an ON-OFF dip switch 
(SW2). Make sure the dip switch SW2 is ON before database
programming.
Before programming the system, switch 
1 (SWl) should be placed in the ON position and powered off and
on to...

Page 345

The modem may be accessed from any station or CO. The MODU port is independent of the MISU RS232C
ports, enabling system database access, etc., without interrupting the SMDR output.
To install the MODU:
1Using a grounding strap, unpack the MODU from its anti-static bag in the packing box.
2Locate the CN6 connector (outlined) on the MBU.
3Locate the CNI connector on the MODU.
4Position the MODU so the CNI matches with CN6 on the MBU.
5Push the MODU onto its connector, making sure it is properly seated....

Page 346

 I
2-12Installation
Miscellaneous Interface Unit (MISU) Installation
Inllnl~llnl~l~l~l~~~l~l~l~l~l~l~l~l~l~l~l~l~l~~~l~l~l~l~l~l~l~l~l~~
Miscellaneous lnterf ace Unit (MISU) Installation
The Miscellaneous Interface Unit (MISU) contains the second external music source (MOH/BGM) and two
serial ports.
To install the MISU:IUsing a grounding strap, unpack the 
MISU from its anti-static conductive bag in the
packing box.
2Locate the CN15 connector (outlined) on the MBU.
3Locate the CN3 connector on the MISU....

Page 347

Installation
Miscellaneous Interface Unit (M&U) Installation
2-13
Figure 2-6: STARPLUS Triad-S Miscellaneous Interface Unit (MISU)
This completes the MISU installation.
STARPLUS Triad-S Installafion Manual
l5llmlmlmll5llmlmll5il
issue I- December 1998 

Page 348

DTMF4-A Unit
The DTMF4-A provides the additional four DTMF receivers that may be used for detecting the DTMF signal
from the single line telephone port or central office line.
To install the 
DTMF4-A:
1Using a grounding strap, unpack the DTMF4-A from its anti-static conductive bag in the
packing box.
2Locate the CN13 and CN14 connectors (outlined) on the MBU.
3Locate the 
CONN5 and CONNG connectors on the DTMF4-A.4Position the 
DTMF4-A so CONN5 and CONNG match CN13 and CN14 on the MBU.
5Push the DTMF4-A...

Page 349

 IInstallation2-15
Message Wait Unit (MSGU)
r;nllnl~llnllnllsrllslllnlInl~l~l~l~Lnl~l~l~~~i~l~l~ILSII~i~1~114ll~lLfll~i~l~11511
Message Wait Unit (MSGU)
The Message Wait Lamp Relay Control (MSGU) provides message wait lamp relay control for message lamp
f
--_;*-... : ”
g?
single line telephones. The MSGU board mounts on the CSIB as a daughter-board-type arrangement. The
CSIB interfaces with mechanical 
9OV AC ringers and 95V DC lights on 2500~type phone sets,
To install the MSGU:
1Using a grounding...

Page 350

CKIBESIB Installation
There are two types of expansion boards available: CKIB and CSIB. These boards include 3 loop start CO line
interfaces and 
8 digital key telephone interfaces (MB), or 3 loop start CO line interfaces and 8 single
line 
telephone interfaces (CSIB).
To install the CKIWCSIB:I
Using a grounding strap, unpack the CKIB/CSIB from its anti-static conductive bag and
six standoffs from the auxiliary bag in the packing box.
2Unscrew the six screws from the CKIB/CSIB installed in the first slot...