To Reduce the Risk of Fire or injury to persons, Read and Follow these instructions: 1. Use only the following type and size battery(ies) listed here as the rnaximurn battery type and size: 24vdc, 40AH. 2. Do not dispose of the battery(ies) in a fire. The cell may explode. Check with local codes for possible special disposal instructions. 3. Do not open or mutilate the battery(ies). Released electrolyte is corrosive and may cause damage to the eyes or skin. It may be toxic if swallowed. 4....
Page 12
For a period of twelve (12) months ti-om the date of shipment to Buyer, Vodavi Comrnunications‘Systems, Inc. warrants the equipment (except for fuses and lamps) to be Ii-ee from defects in material and workmanship. In the event that during the term of the warranty the product should prove to have material or workmanship defects, Vodavi Communications Systems, Inc. will repair, or in its discretion, replace the defective equipment. No equipment of any kind may be returned without prior authorization...
Page 13
1.2 SYSTEM TECHNOLOGY The Starplus Digital Hybrid System (DHS) is a lily digital key telephone system comprised of an -. application configurable, expandable Key Service Unit (KSU) platform. The common system architecture supports three digital telephone models and an expandable D/A, A/D analog device interface. nie DHS is designed to meet the telecommunications needs of small to medium sized business offices. The DHS incorporates state of the art digital technology for voice switching and call...
Page 14
2. CONFIGURATION 2.1 Components The Stat-plus@ DHSm platform is comprised of three key telephone models and a modular KSU (Key Service Unit) which houses the following KSU components: CPU Module Standard 3X8 Module Standard MOH/BGM Module (equips one music channel) 3X8 Expansion Module(s) 6 Port CO Module Option Module In the standard configuration the KSU is equipped to service three (3) CO Lines and eight (8) Star-plus@ DHSTM digital key telephones. The standard configuration is equipped to...
Page 15
The following system configttrations are possible: *- 1-3X8 module 2-3X8 modules / 3 I 8 6 I 16 . I I 3-3X8 modules 9 I 24 : - 1-3X8 module and : : i . i 1-6 Port CO Module 9 8 i ,z : . / 2-3X8 modules and i 7 1 i I l-6 Port CO Module I 12 I 16 i i . 2.1.1 Station apparatus is comprised of the following components: l Executive Key Telephone l Enhanced Key Telephone l Basic Key Telephone l 2 Port SLT Adapter l 2 Port SLT Expansion (Note: key telephones are available in two...
Page 16
KSU (cover remoed) 2.4 Power Supply The power supply circuitry of the Starplus@ DHSTM incorporates a linear design transformer with a choice of input voltage taps. The transformer primary windings are shipped wired for 117vac applications. A factory insulated tap wire may alternately be connected for 230vac applications. Since the power supply is linear in design the output voltage varies between 2 1.6vdc and 32vdc depending on load and stability of the input voltage. The output voltage is...
Page 17
2.5 CPU The CPU board is standard in the Basic KSU. This board contains all circuitry required to control the tilly equipped Starplus@ DHS TM. Three buss connectors are provided where the station/CO line interface 3X8 Expansion Module and 6 Port CO Module are connected. The Option Module connector and Standard MOH Module [email protected] also located on the CPU board. All digital voice switching and call processing data switching is accomplished on the CPU board. The CPU and common control statistics...
Page 18
port SLT devices have a port gain characteristic that allows two SLT (analog) devices to be operated from one digital key telephone port. Each digital station interface is protected against circuit wirin, 0 shorts by an over-current protection polyswitch. The digital station circuit requires only one cable pair to operate and is not polarity sensitive. Physical connection of stations and CO lines to the 3X8 module is made through one 25 pair amphenol- type connector to the MDF (Main Distribution...
Page 19
2.8 6 Port CO Module The 6 Port CO Module may alternately be equipped in place of either 3X8 Expansion Module. The 6 Port CO Module interfaces 6 loop-start CO lines only. No station interface is provided on this module. The 6 Port CO Module is shipped with four (4) mounting stand-offs used to install the board into the Basic KSU, IWO(~) six-conductor modular line cords and two (2) six-conductor modular blocks. The.mounting cords and modular blocks are used to extend the CO line interface circuits...
Page 20
-. 2.9 Standard MOH/BGM Module The standard MOH/BGM Module is pre-installed at the factory and used to interface one external music source that will be used for callers who are placed on hold and station users who activate BGM listening. Connection of the external music source to the MOI-IBGM Module is made via an eighth-inch phono type connector. 2.10 Option Module The Option Module replaces the standard MOWBGM Module. This module comprises all additional system resources required to make all...