STARPLUS 616EX ISSUE 2 JULY I,1987 500.27 SMDRlBAUD RATE (Data Field 36) Station buttons 10 and 1 1 govern these features: 10 - all calls (lit) or long distance only (unlit) 1 1 - 300 baud (lit) or 1200 baud (unlit) Toggle buttons on or off according to programming desired. Press HOLD button. 500.28 DATA BASE PRINTOUT (Data Field 37) Press I‘ l 37” on the dial pad. Then press one of the following buttons depending on what information is needed in the printout. STA 10 - station data STA 1 1 -...
Page 52
STARPLUS 616EX ISSUE 2 JULY I,1987 TABLE 5-5 SAMPLE DATA BASE PRINTOUT STATION CONFIG CKT NUM COS DND SPD ALM PFL 10 1 1 Y Y N N CF DSLT CO ACCESS B/NA Y Y 123456 PGGRP PKGRP PGACC HDST < 1 1 Y N Cl
Page 54
STARPLUS 616EX ISSUE 2 JULY 1, 1987 500.29 TOLL RESTRICTION TABLES (Data Field 41 -44) Use the following Data Fields to program toll tables: Toll Allow Table A - Field 41 Toll Allow Table B - Field 42 Toll Allow Table B - Field 43 Toll Deny Table B - Field 44 - Upon entering the data field, DSS button #l 0 will be lit. - Dial the allow/deny number including ‘don’t cares’. (8 digits maximum) - Press HOLD for entering the data. DSS button #I 1 will then automatically light up. - Enter the...
Page 55
STARPLUS 616EX ISSUE 2 JULY 1,1987 500.30 STATION SPEED DIAL Each telephone has 10 unique speed dial numbers. These numbers are entered and stored by the user and can be recalled by the user at any time. The * (asterisk) is used to program pulse to tone switchover; the # (pound) is used to program a pause; and the flash button to program a flash command. There can be up to 16 digits in each speed dial including pause, pulse to tone switchover and flash commands. A CO line can be programmed for...
Page 56
DIGITS ARE DIALED ON A CO LINE NO RESTRICTION APPLIED CALL 6 ALLOWED YES NO RESTRICTION CALL IS ALLOWED THE CALL VIOLATES THE COS 4 RULES CALL IS RESTRICTED TOLL RESTRICTION FLOW CHART FIGURE 5.1 I DO THE DIALED YES YES ARE DIGITS MATCH THE THERE ENTRIES 3 DENY TABLE IN THE DENY TABLE NO NO RESTRICTION RESTRJCT~~N is APPLIED CALL IS ALLOWED CALL IS DENIED NO RESTRICTION CALL IS ALLOWED ,
Page 57
STARPLUS 616EX ISSUE 2 JULY I,1987 CO LINE PROGRAMMING Private Line 12 DSS 13 None Day Ring 13 All Ring Attendant Night Ring 14 Flash Timer 15 Ring Detect 16 Dial Pulse 17 All Ring Attendant 2 sec. 300 msec. 60/40 10 PPS 5-20
Page 58
STARPLUS 616EX ISSUE 2 JULY I,1987 ‘ SYSTEM PROGRAMMING 27 Executive/Secretary 4 Pairs Sta #, Sta ff None 28 Loud Bell Control Sta # None 30 PBX Codes 4 Nos., 1 or 2 Digit None 31 Attendant Position 1 o-25 Sta 10 32 Ring Timer - Preset Fwd 1 O-99 sec. 15 sec. 33 Station - Preset Fwd Unlimited Sta#, Sta# None 34 Conference Timer 00-99 min 15 min L 5-21
Page 59
STARPLUS 616EX ISSUE 2 JULY 1,1987 STATION PROGRAMMING ‘ Class of Service Do Not Disturb System Speed Preferred Line Ans. Call Fwd Auto Select Headset Page Access CO Line Access ‘Page Grp Pickup Grp STATION PROGRAMCODE 10 11 12 13 14 15 16 17 DEFAULT 01 cos 1 02 co 1 Yes 02 co 2 Yes 02CO4 No 02 co 5 Yes 02CO6 Yes 03COl No 03CO2 Yes 05 All Sta., All Lines 06 Group 1 07 Group 1 (04) DSS ASSIGNMENTS (Station no. to Station no.) FROM TO FROM TO FROM TO FROM TO FROM TO...
Page 60
STARPLUS 616EX ISSUE 2 JULY I, 1987 Programmed at Attendant Station. SYSTEM SPEED DIAL DIGITS 1 2 3 4 5 6 7 8 9 IO 11 12 13 14 15 16 10 / I I I B22; i ! ! 1,231 j ; N24/ 1 1 L25j : / ; _+--__I _ -_/_j_ , 0, 26 i i I / ;I 27 / i I I I / I I I / I / i T28 I / , I I I I 29 I I I 030 / I I ;31 I- I j --7 32 I _ ___.~I 33 ! / j I -1 34 I ’ 35 I / ! I I : I / / I -. 36 37 I i,j ;I;;] I 38 39 I -.i_ 40 I / i 41 42 I- I 43 44 / 45 1 46 47 48 49 5-23