Page 31
STARPLUS 616EX ISSUE 2 JULY 1,1987 400.13 EXTERNAL PAGING An amplifier for external paging may be connected to the 616EX Key Telephone System. Any telephone in the system can access this paging equipment by using a dial code. There is one (1) External Paging Zone (without amplifier) provided for in the 616EX System. Two way talkback paging is also possible. The output impedance of the paging zone is 600 Ohms at 0 d6m. The low level voice signal output is specified at 5 milliwatts. Dry contact...
Page 32
STARPLUS 616EX ISSUE 2 JULY 1,1987 400.17 PRINTER INSTALLATION Figure 4.4 illustrates the standard pin configuration used with the STARPLUS 616EX Key System in connecting display devices. The STARPLUS 616EX is fully compatible with standard RS-232C devices. An RS-232C type connector is provided on the right side or the Enhanced KSU for quick connection of a 4 printer or other receiving device. The receive transmission speed of the connected, terminal should be set at either 300 baud or 1200...
Page 33
STARPLUS 616EX ISSUE 2 JULY 1, 1987 TABLE 4-2 J-l CONNECTING BLOCK LAYOUT Station # Telephone tine Cord GREEN Station IO RED BLACK YELLOW GREEN Station 11 RED BLACK YELLOW GREEN Station 12 RED BLACK YELLOW GREEN Station 13 RED BLACK YELLOW GREEN Station 14 RED BLACK YELLOW GREEN Station 15 RED BLACK YELLOW GREEN Station 16 RED BLACK YELLOW GREEN Station 17 RED BLACK YELLOW MUSIC-ON-HOLD EXTERNAL PAGE (VOICE) EXTERNAL PAGE DRY CONTACTS ALARM LOUD BELL CONTROL 1...
Page 34
STARPLUS 616EX ISSUE 2 JULY I,1987 TABLE 4-3 &2 CONNECTING BLOCK LAYOUT I Station # I Telephone I 2 pr. Twisted bne Cord Station Cable I I GREEN I WHiBL I Statio;l 18 I RED ! BL’WH BLACK WH!OR I I YELLOW : ORiWH I GREEN WH;BL i Siatlon 19 RED BLACK 1 BL;WH YELLOW / WHiOR 0R;WH / Station 20 I I- I Statjon 21 ! Station 22 I Station 23 Statlon 24 Station 25 GREEN WH/BL RED / BUWH BLACK WHiOR YELLOW I OR/WH .-~ GREEN WH. ,3L RED BL’WH BLACK WH,OR YELLOW OR WH...
Page 35
STARPLUS 61613 ISSUE 2 JULY I,1987 CONNECTING , BLOCK MOUNTING PLATE WALL MOUNTING THE KEY TELEPHONE FIGURE 4.1 PLATED STUDS 4-1 1
Page 36
STARPLUS 616EX ISSUE 2 JULY 1,1987 PROCESSOR OR POWER FAILURE STATION STATION WIRING I 66Ml-50 I TERMINAL 1 BLOCK Jl MDF I I I KSU RJI 1 C INPUT 1 FROM RJ21X - NOTE 1 TIP I I CO LINE 1 RING I TIP I I VI-GN I I I I RING I GN-VI , I I I I I TIP I I I 1 I CO LINE 2 I RING I I I I I TIP VI-EN I I I I I I I I I I I RING I BN-VI I TIP Note1 : Contacts are shown in power failure mode PROCESSOR OR POWER FAILURE TRANSFER FIGURE 4.2 4-12
Page 37
STARPLUS 616EX ISSUE 2 JULY I,1987 44+-& m ,9 BN/YL l L--------_A Jl CONNECTOR 43 YUGN -4 18---1- 45 YUSL 3 2. SUYL 46 -G 21* EPVT -- EPVR -- EPCTL -- EPCTL -- ALMT -- ALMR -- LBC 1T -- LBC 1R -- MUSIC SOURCE VOICE ,NP”T IMPEDANCE = 600 ohms @ Odbm OUTPUT TO SPEAKERS MAKE CONTROL e EXTERNAL ALARM DEVICE &+=h LOUD BELL --liz2~~oNTRoL’ CUSTOMER PROVIDED DC EXTERNAL CONNECTIONS FIGURE 4.3 4-13
Page 38
STARPLUS 616EX ISSUE 2 JULY I,1987 500 CUSTOMER DATA BASE PROGRAMMING 500.1 INTRODUCTION The 616EX Key Telephone system can be programmed to meet each customers’ individual needs. All programming is done at station number 10 using either the Executive or Enhanced 616 Electronic Key Telephone as the programming instrument. Upon entering the program mode. the key telephone no longer operates as a telephone but as a programming instrument with all of the buttons redefined. The keys of the dial...
Page 39
STARPLUS 616EX ISSUE 2 JULY 1,1987 500.2 CUSTOMER DATA WORKSHEET Before any attempt at programming is made, the customer data worksheets should be prepared. These worksheets should become the permanent record of the customer data base. When preparing the worksheet, refer to Section 500.3 for information on specific data fields. 500.3 DATA BASE FIELDS The data fields provide for setting system timers, central office line configuration and key telephone configuration. Table 5-1 lists the default...
Page 40
STARPLUS 616EX ISSUE 2 JULY 1,1987 Field Description Data Field Sub Field Station Configuration Class of Service DND SYStem Speed Dial Access Alarm/Door Signal Preferred Line Answer Call Forwarding Direct DSS CO Select Headset Paging Access Flexible DSS CO line access Page Group Pickup Group CO Line Configuration tine Group Lind Type Signalling Toll Override Private Line CO Line Ring-Day CO Line Ringing-Night Flash Timer CO Ring Detect Dial Pulse System Configuration CO’Line...