Page 41
STARPLUS 616EX ISSUE 2 JULY 1,198 500.6 STATION CLASS OF SERVICE (Data Field 01) Press DSS button of station to be assigned COS. Press CO line button of class desired (LED is lit): Class 1 =CO line 1 button Class 2=CO line 2 button Class 3=CO line 3 button Class 4=CO line 4 button Class 5=CO line 5 button Class 6=CO line 6 button Press HOLD button. 500.7 STATION DATA (Data Field 02) Press STA button for station to be programmed. Toggle CO line buttons on and off to determine features. If...
Page 42
STARPLUS 616EX ISSUE 2 JULY 1,1987 Auto Select A station allowed this feature (LED on) can automatically place the telephone in the dialing mode by simply pressing a DSS or CO line button. When the called party answers, the handset must be lifted to converse unless equipped with a speakerphone. I STATION DATA (Data Field 03) Press STA button for station to be programmed. ;, Headset TO change a feature, press appropriate CO line A yes entry (LED on) means that the station has button so LED...
Page 43
STARPLUS 616EX ISSUE 2 JULY 1,1987 500.9 CO LINE ACCESS (Data Field 05) Press STA button for station to be programmed. Press CO line button(s) for the line(s) that station will be able to access. LED on -access LED off - no access Press HOLD button. 500.10 PAGING GROUPS (Data Field 06) Press STA button of station to be programmed Press CO lines to indicate paging groups: CO 1 -group 1 CO 2 -group 2 Press HOLD button. Next STA button will light for programming. PICKUP GROUPS (Data Field 07)...
Page 44
STARPLUS 616EX ISSUE 2 JULY 1,1987 500.12 CO LINE PROGRAMMING (Data Field 12) STA LED’s will be lit indicating current programming. Toggle station button on and off to change a feature. If the LED is lit, values are indicated in parentheses. STA 10 - line type (CO) STA 1 1 - signalling (tone) STA 12 - toil restriction override (yes) STA 13 - private line (no) Press HOLD button. 500.13 CO LINE RINGING -DAY (Data Field 13) Press CO Line to be programmed. Toggle STA buttons on and off to...
Page 45
STARPLUS 616EX ISSUE 2 JULY 1,1987 500.14 CO LINE RINGING - NIGHT (Data Field 14) Press CO line to be programmed. Toggle STA buttons on and off to indicate which stations will ring on that line. LED on =ring LED off= no ring Press HOLD. 500.15 FLASH TIMER (Data Field 15) Press CO line button for which the timer will work. Enter 2 digit timer value on the dial pad (01-99 which corresponds to 0.1 to 9.9 seconds). Press HOLD button. The next CO line will automatically light up for...
Page 46
STARPLUS 616EX ISSUE 2 JULY 1,1987 Station Assignment Program Day Service Activity Station Assignment Program Night Service (Marked Night Ringing) Activity TABLE 5-2 ACCESS AND RINGING -DAY Access & Ring ~___~ Outdialing Incoming LEDs Flash Incoming Ring LEDs Follow System Activity Can Flash Can Receive Transfer Access & No Ring Outdialing Incoming LEDs Flash No Incoming Ring LEDs Follow System Activity Can Flash Can Receive Transfer i- No Access & No Access & R,ing ,...
Page 47
STARPLUS 616EX ISSUE 2 JULY 1, 1987 500.18 SYSTEM CONFIGURATION (Data Field 21) STA LED’s will be lit indicating current programming. STA 10 -queuing STA 1 1 - hold preference STA 12 - alarm detection STA 13 - alarm signaling mode STA 14 - automatic privacy STA 15 -alarm enable STA 16 - BGM enable Toggle STA buttons on and off to change features STA 10 lit - queuing allowed STA 1 1 lit - system hold STA 12 lit - closed loop STA 13 lit - continuous tone STA 14 lit - privacy enabled STA 15...
Page 48
STARPLUS 616EX ISSUE 2 JULY I,1987 500.19 SYSTEM TIMERS (Data Fields 22-26) Exclusive Hold Recall (Data Field 22) Enter data field and dial 3 digit number between 000 and 255. Press HOLD button. System Hold Recall (Data Field 23) Enter data field and dial 3 digit number between 000 and 255. Press HOLD button. Transfer Recall (Data Field 24) Enter data field and dial 3 digit number between 000 and 25.5. Press HOLD button. Message Wait Reminder Tone (Data Field 25) Enter data field and dial...
Page 49
STARPLUS 616EX ISSUE 2 JULY 1, 1987 500.20 EXECUTIVE/SECRETARY ASSIGNMENTS (Data Field 27) Upon entering program field, CO line 1 will be lit for entering the first pair. Press STA button to assign executive. (LED will light steady) Press second STA button to assign secretary. (LED will flash) Press HOLD button. CO line 2 will light for programming the second pair, then CO line 3 for the third pair and CO line 4 for the forth pair. Press HOLD after each pair entered. There are 4 sets of...
Page 50
STARPLUS 616EX ISSUE 2 JULY 1,1987 500.24 CALL FORWARD PRESET (Data Fields 32 and 33) Station Assignment (Data Field 33) Press STA button of station to be automatically Ringing CO lines can be forwarded to another forwarded (LED lights steady). predetermined station if the original station is busy or Press STA button of station to receive the forwarded does not answer. These lines will ring for a call (LED flashes). programmed period of time before forwarding. Make all entries desired. During...