Page 41

Installation
Vidikron Vision 70 Series Owner’s Operating Manual 29 
PREL
IMINARY
Connecting 12-Volt Trigger 
Output to External Theater 
Equipment 
If your Vision 70 is equipped with a CineWide with AutoScope system, use the cable supplied 
with the AutoScope Lens Motor to connect the motor to the 12-volt trigger output as shown 
in 
Figure 3-13. 
Figure 3-13. Connecting the 12-Volt Trigger Output to the AutoScope Lens Motor
If your home theater contains a retractable screen, screen mask or other 12-volt...

Page 42

Installation
30 Vidikron Vision 70 Series Owner’s Operating Manual
PREL
IMINARY
Connecting to AC PowerProjector: The Vision 70 ships with 
various types of AC power cords. 
Choose the one that is appropriate 
to your locale. 
Plug the female end of the power 
cord into the AC receptacle on the 
rear of the projector (AC 100V ~ 
240V). Then, connect the other end 
to your AC power source. 
AutoScope Lens Motor: With AutoScope-equipped projectors, an additional power cord is 
provided for the lens motor....

Page 43

Installation
Vidikron Vision 70 Series Owner’s Operating Manual 31 
PREL
IMINARY
3.8 
Changing the OSD 
Language
The Vision 70 OSD language is initially set to English, but can also display the menus in 
French, Spanish, Italian or German. To change the OSD language:
1. Press MENU.
2. Select Installation from the Main Menu and press ENTER.
3. Select Language from the Installation Menu and press ENTER.
4. Press  or  to highlight the desired language. (The change takes effect immediately.)
3.9 
Adjusting...

Page 44

Installation
32 Vidikron Vision 70 Series Owner’s Operating Manual
PREL
IMINARY
3.11 
Installing and Adjusting 
the CineWide Anamorphic 
Lens
If you are installing a CineWide-equipped projector, proceed as follows to install and adjust 
the CineWide anamorphic lens. 
The standard Vision 70/CineWide uses a prismatic-style anamorphic lens. This type of lens 
compresses the height of the image (as opposed to stretching the width) to achieve a 2.35:1 
aspect ratio with a 1.78:1 display device. 
The Vision...

Page 45

Installation
Vidikron Vision 70 Series Owner’s Operating Manual 33 
PREL
IMINARY
1. Use the Pitch/Y-Adjustment Screws and Washers (item #6) to attach the Vertical 
Mounting Brackets (item #5) to the Anamorphic Lens (item
 #1). 
2. Place the lens with the brackets installed on top of (or under, if the projector is inverted) 
the Base Plate (item #2), so that the two threaded posts at the bottom of the brackets 
pass through the corresponding slots on the base plate.
3. Secure the lens assembly to the base...

Page 46

Installation
34 Vidikron Vision 70 Series Owner’s Operating Manual
PREL
IMINARY
The anamorphic lens will almost always be angled with respect to the projector; this is 
normal. 
Once the proper lens angle has been set, firmly tighten the Pitch Adjustment Screws to 
secure the lens in place.
Adjusting the Yaw: Loosen the Yaw/Z-Adjustment Levers to allow the lens to pivot freely 
from side to side. Then, angle the lens to even out any left-right pincushion distortion: 
There may be some pincushion...

Page 47

Installation
Vidikron Vision 70 Series Owner’s Operating Manual 35 
PREL
IMINARY
Once the proper lens angle has been set, firmly tighten the Yaw/Z-Adjustment Levers to 
secure the lens in place. 
Anamorphic Lens Installation 
and Adjustment -  
Vision 70/CineWide with 
AutoScope
The Vision 70 Anamorphic lens mount kit consists of everything shown in Figure 3-16. Some 
components shipped with your projector may differ slightly from what is shown in these 
instructions.
Figure 3-16. Anamorphic Lens...

Page 48

Installation
36 Vidikron Vision 70 Series Owner’s Operating Manual
PREL
IMINARY
Attach Lens Mounting Assembly to Lens Motor Carriage Plate: 
1. Remove the two Yaw/X Adjustment Levers and 1/4-20 Fiber Washers (item #8) from the 
bottom of the Anamorphic Lens Holder (item #5).
2. Place the Anamorphic Lens Holder on top of the AutoScope Carriage Plate (item #7). 
Position the bracket so that the long slot at the bottom of the lens holder is 
perpendicular to the corresponding slots on the carriage plate.
3....

Page 49

Installation
Vidikron Vision 70 Series Owner’s Operating Manual 37 
PREL
IMINARY
Configure Lens Motor Trigger: CineWide with AutoScope maintains constant image height 
independent of the aspect ratio, while using the full display resolution of the projector. It 
accomplishes this by moving the anamorphic lens in front of the primary lens when 
widescreen material is being viewed. When the viewer transitions back to 16:9 or 4:3 source 
material, the anamorphic lens moves out of the light path.
To...

Page 50

Installation
38 Vidikron Vision 70 Series Owner’s Operating Manual
PREL
IMINARY
Adjusting the Height (Y): With the white field still on-screen, loosen the 
Height/Y
 Adjustment T-Screws on either side of the lens. Then, slowly move the anamorphic 
lens into place so that there are no shadows on the top or bottom of the screen: 
When the height is properly set, tighten the Height Adjustment T-Screws to secure the lens 
in place.
Adjusting the Pitch (Angle): Next, angle the lens to even out any...