Installation Vidikron Vision 70 Series Owner’s Operating Manual 29 PREL IMINARY Connecting 12-Volt Trigger Output to External Theater Equipment If your Vision 70 is equipped with a CineWide with AutoScope system, use the cable supplied with the AutoScope Lens Motor to connect the motor to the 12-volt trigger output as shown in Figure 3-13. Figure 3-13. Connecting the 12-Volt Trigger Output to the AutoScope Lens Motor If your home theater contains a retractable screen, screen mask or other 12-volt...
Page 42
Installation 30 Vidikron Vision 70 Series Owner’s Operating Manual PREL IMINARY Connecting to AC PowerProjector: The Vision 70 ships with various types of AC power cords. Choose the one that is appropriate to your locale. Plug the female end of the power cord into the AC receptacle on the rear of the projector (AC 100V ~ 240V). Then, connect the other end to your AC power source. AutoScope Lens Motor: With AutoScope-equipped projectors, an additional power cord is provided for the lens motor....
Page 43
Installation Vidikron Vision 70 Series Owner’s Operating Manual 31 PREL IMINARY 3.8 Changing the OSD Language The Vision 70 OSD language is initially set to English, but can also display the menus in French, Spanish, Italian or German. To change the OSD language: 1. Press MENU. 2. Select Installation from the Main Menu and press ENTER. 3. Select Language from the Installation Menu and press ENTER. 4. Press or to highlight the desired language. (The change takes effect immediately.) 3.9 Adjusting...
Page 44
Installation 32 Vidikron Vision 70 Series Owner’s Operating Manual PREL IMINARY 3.11 Installing and Adjusting the CineWide Anamorphic Lens If you are installing a CineWide-equipped projector, proceed as follows to install and adjust the CineWide anamorphic lens. The standard Vision 70/CineWide uses a prismatic-style anamorphic lens. This type of lens compresses the height of the image (as opposed to stretching the width) to achieve a 2.35:1 aspect ratio with a 1.78:1 display device. The Vision...
Page 45
Installation Vidikron Vision 70 Series Owner’s Operating Manual 33 PREL IMINARY 1. Use the Pitch/Y-Adjustment Screws and Washers (item #6) to attach the Vertical Mounting Brackets (item #5) to the Anamorphic Lens (item #1). 2. Place the lens with the brackets installed on top of (or under, if the projector is inverted) the Base Plate (item #2), so that the two threaded posts at the bottom of the brackets pass through the corresponding slots on the base plate. 3. Secure the lens assembly to the base...
Page 46
Installation 34 Vidikron Vision 70 Series Owner’s Operating Manual PREL IMINARY The anamorphic lens will almost always be angled with respect to the projector; this is normal. Once the proper lens angle has been set, firmly tighten the Pitch Adjustment Screws to secure the lens in place. Adjusting the Yaw: Loosen the Yaw/Z-Adjustment Levers to allow the lens to pivot freely from side to side. Then, angle the lens to even out any left-right pincushion distortion: There may be some pincushion...
Page 47
Installation Vidikron Vision 70 Series Owner’s Operating Manual 35 PREL IMINARY Once the proper lens angle has been set, firmly tighten the Yaw/Z-Adjustment Levers to secure the lens in place. Anamorphic Lens Installation and Adjustment - Vision 70/CineWide with AutoScope The Vision 70 Anamorphic lens mount kit consists of everything shown in Figure 3-16. Some components shipped with your projector may differ slightly from what is shown in these instructions. Figure 3-16. Anamorphic Lens...
Page 48
Installation 36 Vidikron Vision 70 Series Owner’s Operating Manual PREL IMINARY Attach Lens Mounting Assembly to Lens Motor Carriage Plate: 1. Remove the two Yaw/X Adjustment Levers and 1/4-20 Fiber Washers (item #8) from the bottom of the Anamorphic Lens Holder (item #5). 2. Place the Anamorphic Lens Holder on top of the AutoScope Carriage Plate (item #7). Position the bracket so that the long slot at the bottom of the lens holder is perpendicular to the corresponding slots on the carriage plate. 3....
Page 49
Installation Vidikron Vision 70 Series Owner’s Operating Manual 37 PREL IMINARY Configure Lens Motor Trigger: CineWide with AutoScope maintains constant image height independent of the aspect ratio, while using the full display resolution of the projector. It accomplishes this by moving the anamorphic lens in front of the primary lens when widescreen material is being viewed. When the viewer transitions back to 16:9 or 4:3 source material, the anamorphic lens moves out of the light path. To...
Page 50
Installation 38 Vidikron Vision 70 Series Owner’s Operating Manual PREL IMINARY Adjusting the Height (Y): With the white field still on-screen, loosen the Height/Y Adjustment T-Screws on either side of the lens. Then, slowly move the anamorphic lens into place so that there are no shadows on the top or bottom of the screen: When the height is properly set, tighten the Height Adjustment T-Screws to secure the lens in place. Adjusting the Pitch (Angle): Next, angle the lens to even out any...