Uniden Bc9000xlt Wideband Scanner Owners Manual
Have a look at the manual Uniden Bc9000xlt Wideband Scanner Owners Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 50 Uniden manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Troubleshooting If your BC9000XLT is not performing properly, try the steps listed below. PROBLEM SUGGESTION Scanner won’t work.Check the connections at both ends of the AC Adapter. Turn on the wall switch of your room. You could be using an outlet controlled by the wall switch. Move the AC Adapter to another wall outlet. Make sure the power switch is turned on. Poor reception.Check the antenna and its connection. You may be in a fringe area. This may require an optional multi-band antenna. Check with your dealer or local electronics store. Scan won’t stop.Adjust the Squelch Control. Check the antenna connection. It is possible that none of the programmed channels are active at the time. Try the band search. Scan won’t start.Press the bank key again. Make sure there are some programmed channels. Adjust the Squelch Control. Search won’t start.Adjust the Squelch Control. Scanner won’t allow any program inputsCheck the Enter Lock feature. Can’t program channel with alpha characterAlpha character programming is available on channels 1 - 250. Make sure the channel is within that range. If you still cannot get satisfactory results and want additional information, or to return the unit for service, please call Uniden Customer Service at 800-297-1023. 51
Optional Accessories and Replacement Parts 52 Operating Guide (OMBC9000XLT) OPERATING GUIDE CO UN TAUX S TAT U S S CAN S R CM A N UAL AUTO PR O GS E N DALPH A H O LD LIM IT M EMS H IF TLINEEXT SPPRI TURBO CTCSS DATAB RID IMO F F A MN FMW F M 5 KH z1 2 . 5S KH z2 5K Hz CL R5 0K HzH I- C U TL/O DEL AY ATT12 4 75 8 03 6 9 EAFB GC HD IE JF REQ CH A N L O CKS Q U EL CH VO L U M E O F FBC XLT9000 TWIN TURBOBC XLT9000Auto Scanner Betty Bearcat Starter Frequency Guide Mobile Mounting Bracket Assembly Kit (MB001) Cigarette Lighter Power Cord Adapter (PS001) Telescoping Antenna (AT124) External Speaker (ESP25, 8 )W ® AC Adapter (AD580U) CTCSS Board (BC005)Hard Wire Cord (PS002)
Specifications Banks: Total 20 banks Channels: 500 channels Search Band: Total 17 Search bands (AM, NFM, WFM) Frequency (MHz) Mode Steps 25.000 - 25.9950 AM 5.0kHz 26.000 - 28.9950 AM 5.0kHz 29.000 - 53.9950 NFM 5.0kHz 54.000 - 71.500 WFM 50kHz 72.000 - 75.9950 NFM 5.0kHz 76.000 - 107.9500 WFM 50kHz 108.000 - 136.9950 AM 12.5kHz 137.000 - 173.9950 NFM 5.0kHz 174.000 - 215.9500 WFM 50kHz 216.000 - 224.9950 NFM 5.0kHz 225.000 - 399.9875 AM 12.5kHz 400.000 - 511.9875 NFM 12.5kHz 512.000 - 549.9500 WFM 50kHz 760.000 - 805.9500 WFM 50kHz 806.0000 - 823.9875 NFM 12.5kHz 849.0125 - 868.9875 NFM 12.5kHz 894.0125 - 1300.0000 NFM 12.5kHz Scan Rate: Up to 100channels per second Search Rate: Up to 300 channels per second (Turbo Mode) Up to 100 channels per second (Normal Mode) Scan Delay: 2 seconds Audio Output: Max 3W (8Wload) Antenna: 50 ohms (Impedance) Operating Temperature: - 20 ÉC(-4ÉF) to + 60ÉC(+140ÉF) Size: 10-1/2 (W) x 7-1/2 (D) x 3-1/2 (H) Weight: 4 lbs. Certified in accordance with FCC Rules and Regulations Part 15 Subpart C as of date of manufacture. Features, specifications, and availability of optional accessories are all subject to change without notice. 53
UBZZ01248ZZ OPERATING GUIDE BC9000XLT Auto Scanner COUNT AUX STATUS PROG SEND ALPHAMEM SHIFT LINEEXT SP PRI TURBO CTCSS DATA BRI DIM OFF AM NFM WFM 5KHz 12.5 KHz 25KHz CLR 50KHz HI-CUT L/O DELAY ATT A FB GC HD IE JFREQ CHAN SQUELCH VOLUME OFF BC XLT9000 TWIN TURBOHOLD SRC AUTO LIMITSCANMANUAL12 4 75 8 03 6 9 E LOCK BC9000XLT
Precautions Before you use this scanner, please read and observe the following: WARNING! Uniden does not represent this unit to be waterproof. To reduce the risk of fire or electrical shock, do not expose this unit to rain or moisture. IMPORTANT! The installation, possession, or use of this scanning radio in a motor vehicle may be prohibited, regulated, or require a permit in certain states, cities, and/or local jurisdiction. Your local law enforcement officials should be able to provide you with information regarding the laws in your community. Uniden®and Bearcat®are registered trademarks of Uniden America Corporation ©1994 Uniden America Corporation. All rights reserved. Printed in the Philippines
COUNT AUX STATUS SCAN SRCMANUAL AUTO PROG SEND ALPHA HOLD LIMIT MEM SHIFT LINEEXT SP PRI TURBO CTCSS DATA BRI DIM OFF AM NFM WFM 5KHz 12.5 KHz 25KHz CLR 50KHz HI-CUT L/O DELAY ATT 12 4 75 8 03 6 9 E A FB GC HD IE J FREQ CHAN LOCKSQUELCH VOLUME OFF BC XLT9000 TWIN TURBO 123 4 5 6 7 8 9 10 SRC AUTOHOLD LIMIT LINEEXT SP PRI TURBO CTCSS DATA L/O DELAY ATT COUNT AUX STATUS PROG SEND ALPHAMEM SHIFT SCANMANUALBRI DIM OFF AM NFM WFM 5KHz 12.5 KHz 25KHz CLR 50KHz HI-CUT12 4 75 8 03 6 9 E FREQ CHAN LOCKSQUELCH VOLUME OFF A FB GC HD IE J 1. Programming and Status Keys 2. Display 3. Bank Keys 4. ON/OFF/VOLUME and SQUELCH Controls 5. Rotary Tuning Controls6. Numeric and Special Function Keys 7. Scan Keys 8. Mode Keys 9. Search Keys 10. Output Jacks. BC9000XLT Controls
One Year Limited Warranty WARRANTOR: UNIDEN AMERICA CORPORATION (“Uniden”) ELEMENTS OF WARRANTY:Uniden warrants, for one year, to the original retail owner, this Uniden Product to be free from defects in materials and craftsmanship with only the limitations or exclusions set out below. WARRANTY DURATION:This warranty to the original user shall terminate and be of no further effect 12 months after the date of original retail sale. The warranty is invalid if the Product is (A) damaged or not maintained as reasonable or necessary, (B) modified, altered, or used as part of any conversion kits, subassemblies, or any configurations not sold by Uniden, (C) improperly installed, (D) serviced or repaired by someone other than an authorized Uniden service center for a defect or malfunction covered by this warranty, (E) used in any conjunction with equipment or parts or as part of any system not manufactured by Uniden, or (F) installed, programmed by anyone other than as detailed by the operating guide for this product. STATEMENT OF REMEDY:In the event that the product does not conform to this warranty at any time while this warranty is in effect, warrantor will repair the defect and return it to you without charge for parts, service, or any other cost (except shipping and handling) incurred by warrantor or its representatives in connection with the performance of this warranty. THE LIMITED WARRANTY SET FORTH ABOVE IS THE SOLE AND ENTIRE WARRANTY PERTAINING TO THE PRODUCT AND IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES OF ANY NATURE WHATSOEVER, WHETHER EXPRESS, IMPLIED OR ARISING BY OPERATION OF LAW, INCLUDING, BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY DOES NOT COVER OR PROVIDE FOR THE REIMBURSEMENT OR PAYMENT OF INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow this exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you. LEGAL REMEDIES:This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. This warranty is void outside the United States of America. PROCEDURE FOR OBTAINING PERFORMANCE OF WARRANTY:If, after following the instructions in this Operating Guide you are certain that the Product is defective, pack the Product carefully (preferably in its original packaging). Include evidence of original purchase and a note describing the defect that has caused you to return it. The Product should be shipped or delivered freight prepaid by traceable means, or delivered, to warrantor at: Uniden America Corporation Parts and Service Division 4700 Amon Carter Blvd. Fort Worth, TX 76155 (800) 297-1023, 8 a.m. to 5 p.m. CENTRAL, Monday through Friday