    							Programming Channels
    Before you can scan, you must program the channels within a bank. You
    can store one frequency per channel, up to 500 channels. These are the
    banks and their associated channels:
    Bank Channel Number Bank Channel Number
    A 1-25 1 251-275
    B 26 -50 2 276 - 300
    C 51-75 3 301-325
    D 76 - 100 4 326 - 350
    E 101 - 125 5 351 - 375
    F 126 - 150 6 376 - 400
    G 151 - 175 7 401 - 425
    H 176 - 200 8 426 - 450
    I 201 - 225 9 451 - 475
    J 226 - 250 0 476 - 500
    Auto Sort
    Each time you store a frequency, the list of scanning frequencies in the
    bank is automatically sorted by frequency number. This unique Auto Sort
    feature enables faster scanning. When you manually step through a
    bank, however, frequencies are sorted according to channel number.
    Choosing a Programming Method
    With the BC9000XLT, there are five ways to program a channel:
    nManually selecting a channel and frequency, using the numeric
    keypad
    nUsing the Rotary Tuner to select a channel and frequency
    nSearching a band to find active frequencies, and then storing them
    into channels
    nUsing the Auto Store feature to automatically program channels
    nTransfer a programmed frequency from another channel
    11 
    						
    							Programming By Manual Entry
    Use these keys :
    1. Select a frequency.
    Example: Program
    482.7625 MHz into Channel 1.
    2. Pressmto enter the
    Manual Mode.
    3. Enter the channel number, then
    pressm.
    4. Enter the frequency. Then
    presse.
    Example: 482.7625
    If you make a mistake, press
    ?twice to erase.
    12
    COUNT         AUX          STATUS
    SCAN
    SRCMANUAL
    AUTO PROG SEND ALPHA
    HOLD
    LIMIT MEM SHIFT
    LINEEXT SP
    PRI   TURBO        CTCSS             DATA
    BRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT
    L/O                DELAY                ATT
    12
    4
    75
    8
    03
    6
    9
    E
    A
    FB
    GC
    HD
    IE
    JFREQ
    CHAN
    LOCKSQUELCH
    VOLUME
    OFF
    BC XLT9000
    TWIN TURBOSCANMANUALBRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT12
    4
    75
    8
    03
    6
    9
    E
    Scan and Numeric Keys
    Bank A ch 22
    L/O 000.0000MHz
    Bank A P ch 1
    L/O 000.0000MHz
    Bank A P ch 1
    L/O 482.7625MHz 
    						
    							If an error is made during
    programming, or if the frequency is out
    of range, this screen appears. Enter a
    valid channel or frequency number.
    If the frequency is stored in another
    channel, the display will indicate the
    original channel for that frequency.
    To program more channels, repeat steps 3 and 4.
    Presseto store the same frequency into the selected channel.
    Or, select another channel.
    Or, press?twice to clear.
    Programming With the Rotary Tuner
    Use these controls:
    1. Pressmto enter the
    Manual Mode.
    OR
    Press LOCK, then turn the
    Rotary Tuner.
    Note:Make sure theLOCKLED is out.
    2.
    PressCHAN, then turn the knob.
    Example: Channel 52
    Turn right to step up through
    channels, left to step down
    through channels.
    Note:The channel selection flashes on the display, indicating that the
    frequency displayed is not programmed in that channel.
    13
    Bank A P ch 1
    OUT OF BAND
    Bank A ch 1
    DUPLICATE CH 230
    COUNT         AUX          STATUS
    SCAN
    SRCMANUAL
    AUTO PROG SEND ALPHA
    HOLD
    LIMIT MEM SHIFT
    LINEEXT SP
    PRI   TURBO        CTCSS             DATA
    BRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT
    L/O                DELAY                ATT
    12
    4
    75
    8
    03
    6
    9
    E
    A
    FB
    GC
    HD
    IE
    JFREQ
    CHAN
    LOCKSQUELCH
    VOLUME
    OFF
    BC XLT9000
    TWIN TURBOSCANMANUALBRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT12
    4
    75
    8
    03
    6
    9
    E
    FREQ
    CHAN
    LOCK
    Scan, Numeric Keys, and Rotary Tuning Controls
    Bank B ch 49
    L/O 000.0000MHz
    Bank C ch 52
    L/O 000.0000MHz 
    						
    							3. Select a frequency.
    Example: 123.7750
    4. To tune in the frequency, select
    FREQwith the Rotary Tuner
    Mode Selector then turn right to
    step up, left to step down.
    5. Presseto program the
    channel.
    To program more channels with the Rotary Tuner, repeat steps2-5.
    Programming with Search
    The Search feature lets you search for active frequencies in a range you
    choose and store any or all of those frequencies into channels.
    For more information about searching, see “The Search Mode, page 29.
    Use these keys:
    Note:Be sure to set SQUELCH before you begin a search. See
    “Setting the Squelch, page 8.
    14
    12 . 5KHz ch 52
    AM 123.7750MHz
    Bank C ch 52
    123.7750MHz
    COUNT         AUX          STATUS
    SCAN
    SRCMANUAL
    AUTO PROG SEND ALPHA
    HOLD
    LIMIT MEM SHIFT
    LINEEXT SP
    PRI   TURBO        CTCSS             DATA
    BRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT
    L/O                DELAY                ATT
    12
    4
    75
    8
    03
    6
    9
    E
    A
    FB
    GC
    HD
    IE
    JFREQ
    CHAN
    LOCKSQUELCH
    VOLUME
    OFF
    BC XLT9000
    TWIN TURBO
    SRC AUTOHOLD
    LIMITSCANMANUALBRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT12
    4
    75
    8
    03
    6
    9
    E
    FREQ
    CHAN
    LOCK
    A
    FB
    GC
    HD
    IE
    J
    Search, Scan, Numeric, and Bank Keys,
    and Rotary Tuning Controls 
    						
    							1. Select a frequency range.
    See page 53, or see the included Betty Bearcat Starter
    Frequency Guide.Example: 450.000MHz to 456.000 MHz
    2. Pressm.
    3. Enter the frequency and press
    lto enter the lower limit of
    the search range.
    Example: 450.000 MHz
    4. Enter the frequency and press
    lto enter the upper limit
    of the search range.
    Example: 456.000 MHz
    5. PressSto begin the search
    function.
    To exit search, pressm.
    The scanner stops on the first
    active frequency it finds.
    nTo program the frequency, presshto stop searching. Then,
    proceed to step 6a, 6b, or 6c.
    nIf you do not want to program the frequency, pressSto
    continue searching.
    6a. Program the frequency into the
    current channel.
    Presse.
    6b. Program the frequency into
    another channel:
    1. Presshto stop the
    search.
    15
    NFM 450.0000MHz
    NFM 000.0000MHz
    NFM 450.0000MHz
    NFM 456.0000MHz
    SRC NFM 12 . 5 KHz
    MHz 450.3750
    SRC NFM 12 . 5 KHz
    450.3750MHz
    12
    .5KHz ch 53
    NFM 450.3875MHz
    Bank D ch 53
    450.3875MHz
    12
    .5KHz ch 53
    NFM 450.3875MHz 
    						
    							2. PressNto enter the
    Transfer Mode.
    3. Enter the channel
    number.
    Example: Channel 200.
    4. Pressh.
    5. Presseto Program
    the frequency.
    6c. Program the frequency into the first open channel of another bank.
    1. Presshto stop the
    search.
    2. PressNto enter the
    Transfer Mode.
    3. Choose a bank.
    Example: PressD.
    4. Presse.
    16
    Enter Bank or ch
    450.3875MHz
    200
    450.3875MHz
    Bank H ch200
    000.0000MHz
    (Display flip-flops)
    450.3875MHz
    Bank H ch200
    450.3875MHz
    12
    .5KHz ch 53
    NFM 450.3875MHz
    Enter Bank or ch
    450.3875MHz
    Bank IP
    ch201
    450.3875MHz
    Bank IP
    ch201
    450.3875MHz 
    						
    							Programming With AUTO STORE
    This procedure searches a frequency range and automatically stores
    active frequencies into empty channels of the selected bank(s).
    Note: Be sure to setSQUELCHbefore you begin a search. See “Setting
    the Squelch” on page 8.
    Use these keys:
    1. Select a frequency range.
    See page 53, or see the Betty
    Bearcat Starter Frequency
    Guide.
    Example: 810.000 MHz to
    856.000 MHz
    2. Pressm.
    3. Enter the frequency and press
    lto enter the lower limit of
    the search range.
    Example: 810.000 MHz
    4. Enter the frequency and press
    lto enter the upper limit
    of the search range.
    Example: 856.000 MHz
    17
    COUNT         AUX          STATUS
    SCAN
    SRCMANUAL
    AUTO PROG SEND ALPHA
    HOLD
    LIMIT MEM SHIFT
    LINEEXT SP
    PRI   TURBO        CTCSS             DATA
    BRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT
    L/O                DELAY                ATT
    12
    4
    75
    8
    03
    6
    9
    E
    A
    FB
    GC
    HD
    IE
    JFREQ
    CHAN
    LOCKSQUELCH
    VOLUME
    OFF
    BC XLT9000
    TWIN TURBO
    SRC AUTOHOLD
    LIMITPRI   TURBO        CTCSS             DATA
    L/O                DELAY                ATT
    COUNT         AUX          STATUS
    PROG SEND ALPHAMEM SHIFT
    SCANMANUALBRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT12
    4
    75
    8
    03
    6
    9
    E
    FREQ
    CHAN
    LOCK
    A
    FB
    GC
    HD
    IE
    J
    Programming, Search, Scan, Mode, Numeric, and Bank Keys
    and Rotary Tuning Controls
    NFM 450.0000MHz
    NFM 810.0000MHz
    NFM 810.0000MHz
    NFM 856.0000MHz 
    						
    							5. PressUto enter the Auto
    Store Mode.
    6. Select the bank(s) for
    programming. The selected
    bank indicator(s) stop blinking.
    Example:PressCand
    D.
    7. PressUto begin the Auto
    Store.
    The LED on theUkey
    flashes.
    Note:You hear no audio during Auto Store.
    Note:If the bank you chose is already fully programmed, a double
    beep sounds. Choose another bank.
    Searching frequencies
    Storing an active frequency.
    Search resumes.
    To stop Auto Store, pressm,s,orP.
    You can change these functions during Auto Store:
    Frequency Step (See page 35.)
    Turbo Search (See page 31.)
    Signal Mode (See page 36.)
    8. The unit tells you when Auto
    Store is complete.
    18
    Bank AB EFGHIJ
    1234567890CD
    1 2 . 5KHz STOch 54
    NFM MHZ810.0625
    1 2 . 5KHz STOch 54
    NFM 810.1125MHZ
    1 2 . 5KHz STOch 55
    NFM MHZ810.2000
    Store CD
    end
    Bank ABCDEFGHIJ
    1234567890 
    						
    							Deleting a Programmed Frequency
    Use this procedure when you want to delete a frequency from a channel
    without storing a new frequency in its place.
    Use these keys:
    1. Enter the channel
    number.
    2. Press0.
    3. Presse.
    Transferring a Programmed Frequency
    This procedure lets you transfer a programmed frequency to another channel.
    1. Pressm.
    2. Enter the channel number and
    pressm, or selectCHAN
    with the Rotary Tuner Mode
    Selector and locate the
    channel.
    19
    COUNT         AUX          STATUS
    SCAN
    SRCMANUAL
    AUTO PROG SEND ALPHA
    HOLD
    LIMIT MEM SHIFT
    LINEEXT SP
    PRI   TURBO        CTCSS             DATA
    BRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT
    L/O                DELAY                ATT
    12
    4
    75
    8
    03
    6
    9
    E
    A
    FB
    GC
    HD
    IE
    JFREQ
    CHAN
    LOCKSQUELCH
    VOLUME
    OFF
    BC XLT9000
    TWIN TURBO
    SRC AUTOHOLD
    LIMIT
    COUNT         AUX          STATUS
    PROG SEND ALPHAMEM SHIFT
    SCANMANUALBRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT12
    4
    75
    8
    03
    6
    9
    E
    FREQ
    CHAN
    LOCK
    Programming, Search, Scan, and Numeric Keys,
    and Rotary Tuning Controls
    Bank D ch 86
    854.8625MHz
    Bank D ch 86
    L/O 000.0000MHz
    Bank D ch 53
    450.3875MHz
    Bank D ch 83
    855.9125MHz 
    						
    							3a. To select the transfer channel,
    pressN...
    3b. Then enter the channel
    number...
    3c. Then pressh.
    4. Presseto transfer the
    frequency.
    Programming Channels with Alpha Characters
    Use this feature to name programmed channels (from 1 - 250) for easy
    reference.
    Example: Channel 1, Local Police.
    Use these keys:
    20
    Enter Bank or ch
    855.9125MHz
    8
    855.9125MHz
    Bank A ch 8
    000.0000MHz
    (Display flip-flops)
    Bank D ch 83
    855.9125MHz
    Bank A ch 8
    855.9125MHz
    COUNT         AUX          STATUS
    SCAN
    SRCMANUAL
    AUTO PROG SEND ALPHA
    HOLD
    LIMIT MEM SHIFT
    LINEEXT SP
    PRI   TURBO        CTCSS             DATA
    BRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT
    L/O                DELAY                ATT
    12
    4
    75
    8
    03
    6
    9
    E
    A
    FB
    GC
    HD
    IE
    JFREQ
    CHAN
    LOCKSQUELCH
    VOLUME
    OFF
    BC XLT9000
    TWIN TURBO
    SRC AUTOHOLD
    LIMITPRI   TURBO        CTCSS             DATA
    L/O                DELAY                ATT
    COUNT         AUX          STATUS
    PROG SEND ALPHAMEM SHIFT
    SCANMANUALBRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT12
    4
    75
    8
    03
    6
    9
    E
    FREQ
    CHAN
    LOCK
    Programming, Search, Scan, Mode, and Numeric Keys,
    and Rotary Tuning Controls 
    						
    All Uniden manuals Comments (0)

    Related Manuals for Uniden Bc9000xlt Wideband Scanner Owners Manual