Home > Uniden > Communications receiver > Uniden Bc9000xlt Wideband Scanner Owners Manual

Uniden Bc9000xlt Wideband Scanner Owners Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Uniden Bc9000xlt Wideband Scanner Owners Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 50 Uniden manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Using Auto Recording
    The Auto Recording feature allows you to automatically tape record
    activity from any channel of your scanner. When scanning stops on the
    assigned channel, the recorder records the broadcast.
    Before using the Auto Tape feature, connect the scanner to a tape
    recorder. (See page 6.)
    Use these keys:
    1. Presss.
    2. When the scanner stops on a
    channel you want to record,
    pressm, then pressx.
    Note:You can also select the channel manually.
    To select other channels for recording, repeat steps 1 and 2.
    To record transmissions, you need a tape recorder with Remote and
    Microphone inputs.
    1. Connect the REMOTE jack of your tape recorder to the AUX jack
    on the rear of the BC9000XLT. This can be used to start and
    stop your recorder.
    2. Put a tape in your recorder, and put it in the Record mode.
    3. Presss.
    41
    COUNT         AUX          STATUS
    SCAN
    SRCMANUAL
    AUTO PROG SEND ALPHA
    HOLD
    LIMIT MEM SHIFT
    LINEEXT SP
    PRI   TURBO        CTCSS             DATA
    BRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT
    L/O                DELAY                ATT
    12
    4
    75
    8
    03
    6
    9
    E
    A
    FB
    GC
    HD
    IE
    JFREQ
    CHAN
    LOCKSQUELCH
    VOLUME
    OFF
    BC XLT9000
    TWIN TURBO
    LINEEXT SP
    COUNT         AUX          STATUS
    PROG SEND ALPHAMEM SHIFT
    SCANMANUALBRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT12
    4
    75
    8
    03
    6
    9
    E
    FREQ
    CHAN
    LOCK
    Status, Scan, and Numeric Keys,
    Rotary Tuning Controls, Line jack
    Bank A P  ch 1
    482.7625MHz
    Record ch 1
    482.7625MHz 
    						
    							When scanning stops on a channel that displays “Record”, the channel
    will automatically be recorded.
    To deselect a channel so that it is not recorded:
    1. Display the assigned channel
    on your screen.
    2. Pressx.
    “Record” disappears on the
    display to indicate that channel
    will not be recorded.
    Viewing Scanner Status Information
    This feature lets you quickly review the settings for several features of the
    BC9000XLT. Use these keys:
    In Scan Mode:
    1. Pressm.
    2. Press and holdufor two
    seconds. You hear two beeps,
    then the status information
    scrolls across the display.
    42
    Record ch 1
    482.7625MHz
    Bank A P  ch 1
    482.7625MHz
    COUNT         AUX          STATUS
    SCAN
    SRCMANUAL
    AUTO PROG SEND ALPHA
    HOLD
    LIMIT MEM SHIFT
    LINEEXT SP
    PRI   TURBO        CTCSS             DATA
    BRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT
    L/O                DELAY                ATT
    12
    4
    75
    8
    03
    6
    9
    E
    A
    FB
    GC
    HD
    IE
    JFREQ
    CHAN
    LOCKSQUELCH
    VOLUME
    OFF
    BC XLT9000
    TWIN TURBO
    SRC AUTOHOLD
    LIMIT
    COUNT         AUX          STATUS
    PROG SEND ALPHAMEM SHIFT
    SCANMANUAL
    Status, Search, and Scan Keys
    Bank C ch 72
    854.2875MHz
    Bank C ch 72
    MODE:NFM
    Bank C ch 72
    STEP:12.5KHz 
    						
    							In Search Mode:
    1.Presshto stop the search.
    2. Press and holdufor two
    seconds.
    You hear two beeps, then the
    status information scrolls across
    the display.
    43
    Bank C ch 72
    HI–CUT:OFF
    Bank C ch 72
    RECORD :OFF
    Bank C ch 72
    DIMMER : BRIGHT
    5 . 0KHz ch 230
    NFM 46.0550MHz
    5 . 0KHz ch 10
    MODE:NFM
    5.0KHz
    ch 10
    HI–CUT:OFF
    5.0KHz
    ch10
    DIMMER:BRIGHT
    5 . 0KHz ch10
    TURBO SRCH: ON
    Bank C ch 72
    CTCSS:OFF 000.0 
    						
    							Use these keys forDisplay LightandHi-Cut
    Display Light
    The Display Light has three settings: BRIGHT, DIM, and OFF.
    1. Pressf.
    2. Press the setting.
    Example: Press#.
    Using Hi-Cut
    To Turn HI-CUT ON or OFF:
    1. Pressf.
    2. Press“.
    You can turn HI-CUT on or off while searching or scanning.
    44
    COUNT         AUX          STATUS
    SCAN
    SRCMANUAL
    AUTO PROG SEND ALPHA
    HOLD
    LIMIT MEM SHIFT
    LINEEXT SP
    PRI   TURBO        CTCSS             DATA
    BRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT
    L/O                DELAY                ATT
    12
    4
    75
    8
    03
    6
    9
    E
    A
    FB
    GC
    HD
    IE
    JFREQ
    CHAN
    LOCKSQUELCH
    VOLUME
    OFF
    BC XLT9000
    TWIN TURBO
    COUNT         AUX          STATUS
    PROG SEND ALPHAMEM SHIFT
    BRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT12
    4
    75
    8
    03
    6
    9
    E
    Status and Special Function Keys
    Bank ABCDEF I
    DIMMER : OFF
    Bank ABCDEF I
    HI – CUT: ON 
    						
    							CTCSS Operation
    This section applies only if you are installing and using an optional
    CTCSS Tone Board with your scanner.
    Installing the CTCSS Board
    Installing the CTCSS Tone Board is a simple procedure, and requires only
    a few minutes following the steps below.
    CAUTION:
    Be sure to turn the scanner off and disconnect the power
    cord before attempting to open the scanner.
    1. Remove the five screws from the top cover.
    2. Carefully lift the cover up from the back of the unit and turn it to
    the left - being careful not break the speaker wire.
    3. Stand the cover on its left side panel.
    (Continued, next page)
    45
    Lift 
    						
    							4. Align the pins on the
    CTCSS Board with
    the sockets on the
    mother board. Make
    sure they gostraight
    into the sockets.
    The 4 pin socket is
    toward the front of the
    scanner.
    The 3 pin socket is
    toward the back of
    the scanner.
    5. Gently push straight
    down on the CTCSS
    Board until the pins
    are fully seated in
    the sockets.
    6. Carefully replace the cover and the five screws.
    Note:The tabs on the cover hook under the front part of the
    chassis.
    46
    To speaker
    (Inside Top
    Cover)CTCSS Board installed
    3 pins4 pins 
    						
    							Using CTCSS
    The CTCSS (ContinuousToneControlSquelchSystem) feature allows
    squelch to be broken during scanning only when a CTCSS Tone is
    received.
    To program a channel for CTCSS, use these keys:
    1. Pressm.
    2. PressP.
    3. PressK.
    4. Enter the channel number.
    5. Pressh.
    47
    COUNT         AUX          STATUS
    SCAN
    SRCMANUAL
    AUTO PROG SEND ALPHA
    HOLD
    LIMIT MEM SHIFT
    LINEEXT SP
    PRI   TURBO        CTCSS             DATA
    BRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT
    L/O                DELAY                ATT
    12
    4
    75
    8
    03
    6
    9
    E
    A
    FB
    GC
    HD
    IE
    JFREQ
    CHAN
    LOCKSQUELCH
    VOLUME
    OFF
    BC XLT9000
    TWIN TURBO
    SRC AUTOHOLD
    LIMITPRI   TURBO        CTCSS             DATA
    L/O                DELAY                ATT
    COUNT         AUX          STATUS
    PROG SEND ALPHAMEM SHIFT
    SCANMANUALBRI             DIM             OFF
    AM            NFM            WFM
    5KHz      12.5 KHz      25KHz
    CLR          50KHz         HI-CUT12
    4
    75
    8
    03
    6
    9
    E
    FREQ
    CHAN
    LOCK
    Program, Search, Scan, Mode, and Numeric Keys,
    and Rotary Tuning Controls
    Bank A ch 8
    855.9125MHz
    ALPHA or CTCSS Select
    Select chan 8
    from 1 to 500
    72
    from 1 to 500
    00 . 0KHz ch 72
    854.2875MHz 
    						
    							6. Use the Rotary Tuner to select
    a tone frequency. (Seepage 49
    for a list of tone frequencies.)
    7. Presseto program the
    frequency.
    After programing the frequency,
    the scanner returns to step three.
    Continue programming CTCSS
    frequencies , or pressm
    to exit.
    To Change the CTCSS Tone Frequency
    1. Pressm.
    2. Find the channel and CTCSS
    Tone Frequency you want to
    change.
    3. PressP.
    4. PressK.
    5. Enter the current channel
    number.
    6. Pressh.
    48
    67 . 0Hz ch 72
    854.2875MHz
    67 . 0Hz ch 72
    854.2875MHz
    Select chan 72
    from 1 to 500
    Bank C ch 72
    854.2875MHz
    ALPHA or CTCSS Select
    Select chan 72
    from 1 to 500
    72
    from 1 to 500
    67 . 0Hz ch 72
    854.2875MHz 
    						
    							7. Use the Rotary Tuner to select
    a new frequency. (See below
    for a list of CTCSS tone
    frequencies.)
    8. Presse.
    After programming the frequency, the
    scanner returns to step four. Continue
    programming CTCSS frequencies, or
    pressmto exit.
    Note:To remove a CTCSS Tone Frequency, from a channel, program
    the frequency as “00.0.”
    CTCSS Tone Frequencies
    000.
    0®67.0 71.9 74.4 77.0 79.782.585.4 88.5 91.5
    94.8 97.4 100.
    0103.
    5107.
    2110.
    9114.
    8118.
    8123.
    0127.
    3131.
    8
    136.
    5141.
    3146.
    2151.
    4156.
    7162.
    2167.
    9173.
    8179.
    9186.
    2192.
    8
    203.
    5210.
    7218.
    1225.
    7233.
    6241.
    8250.
    3
    ¶000.
    0
    49
    77 . 0Hz ch 72
    854.2875MHz
    77 . 0Hz ch 72
    854.2875MHz
    Select chan 72
    from 1 to 500 
    						
    							Care and Maintenance
    General Use
    Write down the programmed channels/frequencies in case of a memory
    loss.
    Firmly press each scanner key so that you hear the entry tone.
    Location
    If strong interference or electrical noise is received, move the scanner.
    Also, a higher antenna location usually results in better reception.
    Do not use the scanner in high-moisture environments, such as a kitchen
    or bathroom.
    Avoid placing the scanner in direct sunlight or near heating elements or
    vents.
    Do not plug the scanner’s AC adapter into an outlet controlled by a wall
    switch. Prolonged periods without power can cause loss of memory.
    Cleaning
    Disconnect the AC adapter while you clean the scanner.
    Clean only the outside of the scanner with a mild detergent.
    To prevent scratches, do not use abrasive cleaners or solvents to clean
    the scanner.
    Do not rub the display window.
    Do not use excessive amounts of water.
    Repairs
    Do not attempt any repairs. The scanner contains no user-serviceable
    parts. Contact the Uniden Customer Service Center at 800-297-1023, or
    take the scanner to a qualified repair technician.
    50 
    						
    All Uniden manuals Comments (0)